1 / 17

WinAC –

News Q1/2004. WinAC –. the SIMATIC S7 in your PC. Overview new WinAC Features. Overview WinAC. WinAC Soft. WinAC Slot. Unified OPC-Solution for SIMATIC. SIMATIC NET OPC. PC with Windows. Improved Performance (about 5x – 10x) Improved Configuration with STEP7 Variable-Browsing

julie
Download Presentation

WinAC –

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. News Q1/2004 WinAC – the SIMATIC S7 in your PC

  2. Overview new WinAC Features Overview WinAC WinAC Soft WinAC Slot

  3. Unified OPC-Solution for SIMATIC SIMATIC NET OPC PC with Windows • Improved Performance(about 5x – 10x) • Improved Configuration with STEP7 • Variable-Browsing • OPC-Interfaces: • Data Access • Alarms&Events • Successor of SIMATIC Computing SIMATIC NET OPC PC Internal WinAC CP …

  4. More compact and cost-effective Automation Solution Multi-PLC Support • Reduced HW-cost,reduced space (less PCs) • Communication using BSEND/BRCV • Distributed control power • < 4 WinAC Slot PLC • 1 WinAC Software PLC +< 3 WinAC Slot PLC • External Power Supply: 1 PS Extension Board per WinAC Slot required Multi-CPU

  5. Motion with WinAC More Motion Solutions with WinAC Slot • FM 353/354 • Support of additional FMs: • FM 353: Stepper Motor • FM 354: Servo Motor • Point to point positioning • Complex traversing patterns • Motion control solutions with SIMOVERT MASTERDRIVES • Electronic Gear More Motion ET200M MASTERDRIVES

  6. Simplified Operation, Maintenance and Service Operation with Simple PC User Privileges • Installation: • Admin or Local Admin privileges required • Operation: • User or Power User privileges sufficient • RUN/STOP/MRES • Read diagnostic buffer • Restoring of archive files • Tuning • Safety: • Panel pass word PC User Rights

  7. Simplified Maintenance and Service Firmware-Update via File • Start FW update via menu command • No more memory card needed • No more creation of „update memory card“ with STEP7 • Note: new HW release 3 required • Upgrade of HW for existing WinAC Slot PLCs required FW Update ... FW-Update via File

  8. WinAC PN Option für WinAC Basis • Modular, distributed Automation with WinAC Basis • Integration of PROFInet into WinAC standard products • Used for Component based Automation • Replacement of WinAC PN V1.1 • Option package for WinAC Basis Ethernet PROFIBUS CbA for WinAC Basis Components with distributed I/O on PROFIBUS Innovations and Trends with PC based Control Products

  9. Performance for WinAC Software PLCs • Notes for Measurement: • 32000 Operations(32 loops à 1000) • Performance values depending on processor type! • Performance values depending on program structure! 1,2 GHz Celeron Performance Performance x 2 3 GHz Xeon (P4)

  10. Integration of Custom Functions Integration of T-Kit und ODK:WinAC ODK V4.1 ODKV4.1 • One C/C++ engineering package for WinAC Software and Slot PLCs • Wizard supported programming for run-time interfaces for WinAC Software and Slot PLCs: Microsoft Visual Studio Slot Soft Wizard ODK Innovation

  11. WinAC ODK V4.1 WinAC ODK V4.0 WinAC Slot T-Kit V3.3 Custom Application(C/C++) Custom Application(C/C++) WinAC ODK V4.1 Custom Application (C/C++) T-Kit DLL ODK Innovation Integratin with ODK CCX CMI SMX CMI SMX WinAC Software PLC V4.1 WinAC Slot PLC V3.4

  12. CCX: Custom Code Extension Interface • Backward compatible to existing ODK Interface • Neu: • Operand Access –access to WinAC data at any time • Programming with Visual Developer‘s Studio .net • Compatibility • WinAC ODK V4.0 can still be used with WinAC Basis/RTX V4.1 • Applications created with WinAC ODK V4.0 can be used with WinAC Basis/RTX V4.1 without any restrictions • Applications created with WinAC Basis/RTX ODK V3.0 can be used with WinAC V4.1 with the same restrictions as with WinAC Basis/RTX V4.0 CCX

  13. SMX: Shared Memory Extension Interface • Enhancement of T-Kit interface • New: • Simplified DLL interface • Supports Multi-CPU operation • Support of WinAC Software PLCs planed • Compatibility: • WinAC Slot T-Kit V3.3 can be used with WinAC Slot V3.4 • Applications created with WinAC Slot T-Kit V3.3 can be used with WinAC Slot V3.4 w/o restrictions; WinAC Slot will provide a “Compatibility DLL” SMX

  14. CMI: Controller Management Interface • New: enables integration of WinAC CPU Panel functionality into a custom application • RUN/STOP/LED-status • Archiving/reloading of PLC programs • Start and shutdown of the PLC • Examples: • Complete integration of CPU Panel functions into a HMI application („Service- und Maintenance pages“) • Remote CPU Panel • Implementation of specific user rights • Automatic reloading of PLC program updates CMI

  15. Reuse of PLC Programs without any change Roadmap & Compatibility 2003 2004 WinAC Soft V3.x WinAC Soft V4.0 WinAC Soft V4.1 WinAC Slot V3.2 WinAC Slot V3.3 WinAC Slot V3.4 • 100% Backward compatibility to predecessor versions • The new versions will replace their predecessors completely Micellaneous

  16. Upgrade • Upgrade Packages for WinAC Software and Slot PLC • One upgrade version required per installation of WinAC Software or Slot PLC because of licenses included • Upgrade with cost • Specifics for WinAC Slot: • FW V3.4 available as Download free of cost • Attention: Feature “FW-Update…” requires HW update with cost! • Upgrade ODK: • Not planed Micellaneous

  17. SIMATIC WinAC SIMATIC WinAC PC-based Control The Integration platform for your PC-based solution

More Related