slide1
Download
Skip this Video
Download Presentation
THEMIS IIRT PRE-SHIP TELECON PFR232 AXB Contamination Jeremy McCauley

Loading in 2 Seconds...

play fullscreen
1 / 2

THEMIS IIRT PRE-SHIP TELECON PFR232 AXB Contamination Jeremy McCauley - PowerPoint PPT Presentation


  • 132 Views
  • Uploaded on

THEMIS IIRT PRE-SHIP TELECON PFR232 AXB Contamination Jeremy McCauley University of California - Berkeley. PFR232: AXB Contamination. PFR232: AXB Contamination Droplets visibly seen on the AXBs when removed Swabs analyzed AXBs: F1,F3-F5 - Glycol Ether; F2 - Clean (HST513)

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' THEMIS IIRT PRE-SHIP TELECON PFR232 AXB Contamination Jeremy McCauley' - janina


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1
THEMIS IIRT
  • PRE-SHIP TELECON
  • PFR232 AXB Contamination
  • Jeremy McCauley
  • University of California - Berkeley
pfr232 axb contamination
PFR232: AXB Contamination
  • PFR232: AXB Contamination
  • Droplets visibly seen on the AXBs when removed
  • Swabs analyzed
    • AXBs: F1,F3-F5 - Glycol Ether; F2 - Clean (HST513)
    • SC: Clean (HST514)
    • RF Hat Absorber Sample: Glycol Ether (HST518)  SOURCE
  • Glycol Ether
    • Found in paints, oils and pesticides as a curing agent
    • Likely to Evaporate
    • Bonds to Polar Solvent (Alcohol)
  • Corrective Action
    • Clean Units with IPA
    • Verify Conductivity of ITO
    • Reinstall