Developments in:
This presentation is the property of its rightful owner.
Sponsored Links
1 / 11

Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds PowerPoint PPT Presentation


  • 102 Views
  • Uploaded on
  • Presentation posted in: General

Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds. j. Background. Wool – Naturally flame retardant and used to meet stricter OEM FST requirements. Used extensively outside USA

Download Presentation

Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Akro fireguard 1207055

Developments in:

- Low Smoke Fire Resistant Floor Coverings

- Low Smoke Fire Resistant Interior Repair Compounds

j


Akro fireguard 1207055

Background

  • Wool – Naturally flame retardant and used to meet stricter OEM FST requirements.

  • Used extensively outside USA

  • Conventional Nylon – Brominated Flame retardants – meets FAA standards.

  • Used extensively in USA

  • Summary:

  • Wool – Good FST Performance – Poor Operational Performance.

  • Meets OEM FST requirements

  • Nylon – Excellent Operational Performance – High smoke and toxic gases.

  • Up to 5x ware improvement

  • AkroBak Nylon – The best features of wool and Nylon

Low Smoke Fire Resistant Floor Coverings:

AkroBak® Nylon Carpet

j


Akro fireguard 1207055

Comparative Data: FST Requirements FAA : OEM

Low Smoke Fire Resistant Floor Coverings

AkroBak® Nylon Carpet

j


Akro fireguard 1207055

Vertical Burn : Summary of Results

Length Direction

Width Direction

Low Smoke Fire Resistant Floor Coverings

AkroBak® Nylon Carpet

j


Akro fireguard 1207055

Comparative Data: Smoke Density

LIMIT

Low Smoke Fire Resistant Floor Coverings

AkroBak® Nylon Carpet

j


Akro fireguard 1207055

Comparative Data: Toxicity

Maximum Allowable

3500

150

100

150

100

100

Actual Akrobak results

100

25

0

0

15

30

Low Smoke Fire Resistant Floor Coverings

AkroBak® Nylon Carpet

j


Akro fireguard 1207055

‘In service Durability’

Testing performed, summary of results

Static propensity – BSS 7311: Leather/Rubber 0.5kV, Composition : 0.6kV - Requirement < 2.5kV

Dimensional Stability (4’x10’ Sample) – BSS 7310: Length: -0.5%, Width 0% - Requirement < 5%

Vetterman Drum Test (22,000 revolutions): Rating 3.3 (Moderate Change) - Requirement N/A

Hexapod Tumbler – ASTM D-5252, 12,000 cycles: Rating 3 (Moderate Change) - Requirement N/A

Ultimate performance indicator - in service experience:

3x improvement in longevity over traditional FST compliant carpeting

Low Smoke Fire Resistant Floor Coverings

AkroBak® Nylon Carpet

j


Akro fireguard 1207055

CONCLUSION

  • AkroBak Nylon Carpet

  • Superior resistance to soiling and staining.

  • Superior durability and maintainability.

  • Low weight.

  • Total cost of ownership

  • Meets the highest FST standards

  • Does not contain Bromine compounds and is therefore compliant with current and

  • Impending legislation.

  • Visit us at http://www.akrofire.com

Low Smoke Fire Resistant Floor Coverings

AkroBak® Nylon Carpet

j


Akro fireguard 1207055

AF444 SpeedFill

  • AF444 SpeedFill was developed to provide a universal filling and repair compound that would meet:

  • OSU Heat Release

  • Vertical Burn

  • Smoke Density

  • Cure characteristics such that the material can be used effectively during ‘change around’ operations.

Low Smoke Fire Resistant Interior Repair Compounds

AF444 SpeedFill

j


Akro fireguard 1207055

Basic Properties

  • FAR 25.853 OSU Heat Release Average: 12 Peak: 45

  • ASTM E662 Smoke Density (flaming mode) 127

  • Vertical Burn12 second & 60 second

  • Compressive Strength6360 psi / 44MPa

  • Density1.16g/cm3 /72lb/ft3

Low Smoke Fire Resistant Interior Repair Compounds

AF444 SpeedFill

j


Akro fireguard 1207055

Handling

  • Mixing:2 pack system, Part A & B, 2% Part B

  • Application:Trowel / Spatula

  • ShapingAfter 10 to 20 minutes

  • Cure30 to 40 minutes

Applications

  • Sandwich Panel core repair:(Airbus approved for cargo liner repairs)

  • Interior panel repair

Low Smoke Fire Resistant Interior Repair Compounds