1 / 18

Conditioning in RF structures

Conditioning in RF structures. A.D., J.G.N. 28-02-2014. Conditioning history of two structures at KEK and CERN. CERN TD26R05CC conditioning history plot . TD26R05 CC conditioned at CERN. automatic conditioning ON. 7e-05 . 2e-05.

jam
Download Presentation

Conditioning in RF structures

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Conditioning in RF structures A.D., J.G.N. 28-02-2014

  2. Conditioning history of two structures at KEK and CERN • CERN TD26R05CC conditioning history plot

  3. TD26R05 CC conditioned at CERN automatic conditioning ON 7e-05 2e-05 equivalent conditioning curve with constant pulse length of 250 ns since the beginning It would take longer time to reach the same gradient with smaller BDR (as expected) • equivalent conditioning curve with: • constant pulse length of 250 ns since the beginning • constant BDR of 1e-6 bpp/m

  4. Conditioning history of two structures at KEK and CERN • TD24R05#4 at KEK

  5. TD24R05#4 conditioned at KEK - history Conditioning BDR measurements

  6. TD24R05 conditioned at KEK 1.4e-06 2.3e-06 5.5e-06 4.8e-06 9.2e-07 2.7e-06 Conditioning curve of TD24R05 at KEK • equivalent conditioning curve with: • constant pulse length of 250 ns since the beginning • constant BDR of 1e-6 bpp/m

  7. BDR during conditioning Moving average with a window of 10 MPulses

  8. Comparison of conditining curves KEK, TD24R05#4 CERN TD26R05CC gradient normalized gradient

  9. Comparison of conditining curves KEK, TD24R05#4 CERN TD26R05CC gradient normalized gradient

  10. Comparison of E0 vs #BD KEK, TD24R05#4 CERN TD26R05CC

  11. Normalized Gradient Overlapped

  12. Normalized Gradient

  13. Normalized Gradient VS #RF Periods (tpulsex12GHz)

  14. Normalized Gradient LOG-LOG scale

  15. Normalized Gradient Slope = 0.287 +/- 0.001 (Slope error corresponds to least-square fit method) LOG-LOG scale + Linear FIT Slope = 0.2579 +/- 0.0006

  16. Normalized BDR LOG-LOG scale

  17. Normalized BDR LOG-LOG scale + Linear FIT (Slope error corresponds to least-square fit method) Slope = -8.35 +/- 0.02 Slope = -7.74 +/- 0.02

  18. Fit of conditioning curves KEK, TD24R05#4 CERN TD26R05CC E0*=a Nb E0*=a log(N) + b