1 / 54

NetClock Time Synchronization Solutions

NetClock Time Synchronization Solutions. Product Sales Training. Spectracom is a Business of the Orolia Group. A high-tech electronics group specializing in Positioning, Navigation and Timing technologies

jace
Download Presentation

NetClock Time Synchronization Solutions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NetClock Time Synchronization Solutions Product Sales Training

  2. Spectracom is a Business of the Orolia Group A high-tech electronics group specializing in Positioning, Navigation and Timing technologies High-precision systems determine the ‘where and when’ in critical operations for systems, people, objects, and events Space & Navigation Positioning Systems Timing, Test & Measurement NetClock Time Synchronization Solutions

  3. Spectracom - Your Partner in Timing Generation, distribution and measurement of time and frequency • Leader in timing and sync since 1972 • Wide range of products and systems • High reliability and superior service • Operations throughout the world ● NetClock Time Synchronization Solutions

  4. Financial Services Healthcare PublicSafety NetworkManagement Transportation Time Synchronization Solutions Network Applications require precise, accurate & stable Time & Frequency Generation and Distribution Higher Education

  5. ADT Alstom Ameritech Amtrak Apple Computer AT&T B F Goodrich Bechtel Bell Bellagio Boeing Brokerage America Burroughs Carolina Power & Light Carrier CBS Chase Manhattan Bank Chevron Chicago Stock Exchange Chrysler Citibank Comp USA Compaq Computer Cray Research CSX Corporation Deutsche Bank Dictaphone Dupont E*Trade Group E-bay EDS Enron Exxon Federal Express Fluke Ford Motor Company 4,500+ 9-1-1 PSAP Centers 500 US Commercial Airports [FAA] GE Glaxo Harris Hewlett Packard Honeywell HP Hughes IBM J P Morgan Learjet Lockheed MCI Merrill Lynch Motorola NCR Nielsen NIST Nokia Northern Telecom Oracle Pacific Gas & Electric Phillips Petroleum Pratt & Whitney Qualcomm Racal SBC Scientific Atlanta Tektronix Time Warner Tyson Foods UPS US Airways USAF Verizon Walt Disney Westinghouse BellagioLas Vegas NetClock Time Synchronization Solutions

  6. Why Time Synchronization? • Different equipment systems display and record different times • No certainty of start/end times for events, tasks, etc. • Without accurate time, you are vulnerable to potential litigation • Eliminates error-prone manual setting NetClock Time Synchronization Solutions

  7. Are Network Problems Degrading Your Efficiencies? • Incorrect Time Causing Transfer Errors? • Erratic LAN-WAN Interconnections? • Transaction Processing Inaccuracies? • Discrepancies of File Time Stamps? • Inaccurate log files • Non-linear Sequence of Events for diagnostics? • Security Infringements? NetClock Time Synchronization Solutions

  8. “One of the still-unanswered questions is the timing of when help was summoned. It would appear that as much as seven minutes may have elapsed after Smith began convulsing and before the Monroe County Emergency Communication Department received the call. But the discrepancy between what police say was an ‘immediate’ call to 911 and what emergency records show could be explained by the agencies involved using different clocks.” —Monroe County, Rochester, NY (The PSAP had NetClock. The jail now uses NetClock.) Heightened Public Awareness An inmate was dying. A delayed call to PSAP was made to 10-digit PSAP Number.

  9. Synchronizing Critical Operations in a PSAP • Key Processes Needing Accurate Synchronized Time : • Call-taking and Recording • Dispatching – CAD database updating • Referrals – handoffs to other centers • Advanced EMS over the phone • Incident command & coordination - NIMS • Coordination with Federal including DHS and DoD • Personnel shift changes • Database backups • PSAP security systems recording of video • Quality Metrics, Process Improvement, Training NetClock Time Synchronization Solutions

  10. What You Do Not Want To See in Your Facility • Physical Security system has “12:22:29” • Display Clock reads “12:16” Which one is right ?? (A medical center’s Public Safety Center) NetClock Time Synchronization Solutions

  11. Why Not Use Internet Time? • Unreliable • Internet sites do not, and cannot, guarantee 24/7/365 availability • Security risk • Open firewall port (NTP uses port 123) is a breach in network security and can elicit Denial of Service attacks • Not accurate • In an MIT survey, 72% of Internet time servers deemed not useful • Not traceable • No audit trails • False sense of synchronization • Not all systems receiving time NetClock Time Synchronization Solutions

  12. Traceability of GPS Time NetClock Time Synchronization Solutions

  13. GPS Broadcast • Global Positioning System of 24 Satellites • Worldwide Coverage • Freq: 1.57542 GHz • Tracks up to 12 satellites • 100 usec Accuracy NetClock Time Synchronization Solutions

  14. NetClock 9483 PSAP Time Server/master clock Back Panel • GPS Antenna input • 10/100Base-T (RJ45) • IRIG B/E, RS-232, RS-485, 10MHZ, 1PPS • Alarm Relays/Contacts • 4 slots for optional card modules Front Panel • Lockable Keypad to set-up IP-address, etc. • LEDs indicate Power, GPS sync status • LED Display for Time, LCD display for network set-up info • RS-232 Console Port NetClock Time Synchronization Solutions 14

  15. New Modular Design – Rear Panel of NetClock • Base Model Connections • 10/100Base-T (RJ45) • 10MHz and 1-PPS • NENA Card for RS-232, RS-485, IRIG, and Alarm Relays • Integral 100-240VAC Power • Antenna • Card Slots Available for Expansion • Available Card Modules - • Multi-Network Port Card:3 x 10/100/1000Base-T • T1 Timing • PTP (IEEE1588) • Dual-Power Supply Option NetClock Time Synchronization Solutions

  16. Rear Panel of NetClock with 3 x Multi-network Port Card Module Advantages over the previous model configuration, which previously required separate 9388 slave time servers connected to the NetClock master, include:  • Single 1RU NetClock with total of 4 network ports – saves rack space • Configuration and management from single unit – single browser manages everything, with separate routing tables for each network • Cost savings – 3 time servers provided for the price of one NetClock Time Synchronization Solutions

  17. NetClock 9483 Fully Complies / Exceeds NENA PSAP MASTER CLOCK STANDARD • Defines where time is sourced from, how it supports PSAP • Time source must provide CONTINUOUS time data to ALL equipment systems in the facility, including CAD, ANI/ALI, Voice/Logging Recorders, Radio Consoles, etc.  NetClock Time Synchronization Solutions

  18. NetClock 9483 Compatible withNENA SECURITY STANDARD • Guidelines and requirements for the protection of NG9-1-1 assets or elements. • Time source must be a protected asset and network element.  NetClock Time Synchronization Solutions

  19. NetClock – Designed to Synchronize ALL PSAP Systems and Devices • Radio Consoles • CAD Systems • VoIP Telephony Systems • Voice Logging Recorders • ANI-ALI Controllers • Emergency Notification System • Network Management System • Radio Test Equipment • Network Servers/Clients • Wall Display Clocks • Time and Attendance System • Physical Security Video Recorder (cctv) • Building Access Control • Scheduled Fire Dept. “Noon Whistle” via contact relay connection • Telecom/SONET networks All displaying the same time/date. All logging the same time/date. NetClock Time Synchronization Solutions

  20. Synchronized Communications Center NetClock Time Synchronization Solutions

  21. GPS Antennas • Standard Model 8225 • 30dB gain • -30C to +80C • Common Features: • Omni-Directional Antenna • Powered by NetClock/GPS • Active Components • Weatherproof • Special Applications • Model ANT-35 • High-gain +35dB • Selective signal filtering • -40C to +85C operation ANT-KT mount *Note: Mounting stand extra (P/N 8213) NetClock Time Synchronization Solutions

  22. GPS Timing Back-up: NetClock Oscillators Maintaining accurate time can be a challenge • Severe weather can affect proper antenna operation, ie. lightning, wind, ice storms • In 2004 the President issued the ‘U.S. SPACE-BASED POSITIONING, NAVIGATION, AND TIMING POLICY’ • GPS can be turned off for Homeland Defense • GPS users should make backup provisions. NetClock Time Synchronization Solutions

  23. Solution – NetClock GPS Back-up Oscillators • Provides Continuous Time Synchronization if GPS Signal is Lost • TCXO Temperature Controlled Oscillator (std.) – 24 Hrs of time synchronization. • OCXO Oven Controlled Crystal Oscillator – 30 days of time sync accuracy without GPS signal. **PSAP-recommended** • Rubidium Oscillator – provides the highest level of timing accuracy and two year operation without GPS (and full T1 timing capable). NetClock Time Synchronization Solutions

  24. Ethernet Time Server Model 9388 Featuring: • Complete network isolation with separate chassis/processor – time server • Stratum-1 server synchronized directly to NetClock master • Shock and Vibration-rated chassis • RoHS environmental design NetClock Time Synchronization Solutions

  25. Site Survey form NetClock Time Synchronization Solutions

  26. NetClock Time Synchronization Solutions

  27. GPS Antenna System NetClock Time Server/master clock NetClock Time Synchronization Solutions

  28. Antenna Installation 8225 Antenna: • Includes 18” long threaded PVC Mast Pipe • Metal Straps to affix onto existing structure • Run antenna coax down through pipe Strap detail NetClock Time Synchronization Solutions

  29. NetClock/GPS Configuration Web browser Interface: • Default IP address – 10.10.200.1 • Configure NetClock to User Application • All parameters have drop-downs for easy setup • Serial Port Interface available to change IP addrs • Use Terminal Emulator Program (Hyperterminal) • Use “Straight Through” Cable, 9600,n,8,1 NetClock Time Synchronization Solutions

  30. Network Time Sync • What is NTP? Network Time Protocol (NTP) is used to synchronize computer clocks with a time reference such as GPS. Endorsed by all the major IT vendors, ie. Microsoft, Cisco, for providing millisecond’s of accuracy on networks. NetClock Time Synchronization Solutions

  31. Windows, Linux, Unix, & Novell Operating Systems Need NTP • Synchronize Servers & Work Stations • Time Stamp Kerberos Security • Synchronize Directory Naming Service (DNS) • Time Stamp File Creation for Audit Trail • Email Dating, Database Updates, … • Logging Requirements, ie. Event Viewer entries NetClock Time Synchronization Solutions

  32. Stratum Level Timing NetClock Time Synchronization Solutions

  33. Web Browser: NetClock Time Synchronization Solutions

  34. GPS Status Screen NetClock Time Synchronization Solutions

  35. NTP Status Screen NetClock Time Synchronization Solutions

  36. Configuring the System - SNMP NetClock can provide SNMP traps when events occur for remote indication of status changes. MIB files are available @ www.spectracomcorp.com NetClock Time Synchronization Solutions

  37. Notification - Timing NetClock Time Synchronization Solutions

  38. PresenTense Synchronization Software • Network Time Management Software for Windows Software • Improves Time Synchronization frequency for better timing accuracies and interoperability • Real-time monitoring and immediate email alert if time sync is changed or lost • Detailed record logs of time sync status • Supports redundant time sources • Auditor program provides hardcopy proof of time sync status for legal requirements NetClock Time Synchronization Solutions

  39. GUI Interface NetClock Time Synchronization Solutions

  40. Redundant Systems NetClock Time Synchronization Solutions

  41. Display Clocks Wired Display Clocks • Model TV400W TimeView 400 • Model TV210W TimeView 210 • Model TV312W TimeView 312 Model TV312 Model TV210 NetClock Time Synchronization Solutions

  42. Wired Display Clock Installation NetClock Time Synchronization Solutions

  43. IP-Sync Display Clocks • Connect directly to the Network for synchronized display time • With PoE networks, a single connection provides both synchronization and power to each display • Integral Web GUI Interface for set-up and monitoring anywhere on the network • Automatic DST Adjustment NetClock Time Synchronization Solutions

  44. WiSync Wireless Display Clocks • 900MHz, frequency-hopping wireless synchronization • Mesh network design - each clock repeats the sync signal • Transmitter synchronizes to the NetClock over the network • Suitable for larger #’s of clock installations NetClock Time Synchronization Solutions

  45. GP933 Command Center Package Multi-LAN environment NetClock Time Synchronization Solutions

  46. Evolution of the NENA-compliant NetClock 8182 NetClock/2 WWVB master clock Serial time codes 8183 NetClock GPS master clock Serial time codes Frequency outputs 9100/9200 NetClock GPS master clock/time server Serial time codes Frequency outputs Integral NTP Back-up Oscillators SSL/SSH, SNMPv3 9383 NetClock GPS master clock/time server Serial time codes Frequency outputs Intergal NTP Back-up Oscillators SSL/SSH, SNMPv3 DHCP, IPv6, Syslog RoHS environmental Shock/Vib Chassis 9483 NetClock GPS time server Serial time codes Frequency outputs Integral NTP Back-up Oscillators SSL/SSH, SNMPv3 High Bandwidth NTP DHCP, IPv6, Syslog RoHS environmental Shock/Vib Chassis Multi-Network Ports PTP & T1 Cards Dual-Power Supply Monolithic designs New Modular design Fully Backward Compatible

  47. If Your Client Has One of These… NetClock Time Synchronization Solutions

  48. Upgrade to NetClock/GPS • GPS Is Inherently More Robust • Not Normally Affected By Weather • Updated Design including • Integral Time Server • Web-Browser GUI Interface • Security Features • GPS Back-up Oscillators • New 5-Year Warranty • WWVB Signal Soon to be changed - sync eliminated • Early ’90’s Design – no longer updated/maintained • No Integral Time Server • Dials and Dipswitches • No Security Features • Discontinued Product NetClock Time Synchronization Solutions

  49. Upgrade to NetClock®/GPS Model 9483 and get a free Digital Display or a $300 check* Trade-in this: 8182, NetClock/2, 8183, 9183 • Discontinued product, spare parts availability issues • Doesn’t meet current NENA standards • Uses older WWVB signal that can be affected by weather conditions and UPS systems • No Ethernet capability • Old software platform no longer supported • Dip-switches and setscrews for configuring or For this: 9483 NetClock GPS • Meets and exceeds current NENA standards • 5 Year Warranty • Built-in Ethernet/NTP to support WIN2K+ • GPS-based, with Back-up Oscillator • Precision oscillator options to maintain timing • Fully secure with SSL, SSH & SNMP V1,2,3 • RoHS environmentally rated • Easy Web-browser interface $300 Check OR NetClock Time Synchronization Solutions

More Related