PANDUIT Advisory Services FlexPod Site Readiness Assessment Services

PANDUIT Advisory Services FlexPod Site Readiness Assessment Services. Service Value Proposition. P ANDUIT Advisory Services.

ion
Download Presentation

PANDUIT Advisory Services FlexPod Site Readiness Assessment Services

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PANDUIT Advisory ServicesFlexPod Site ReadinessAssessment Services

  2. Service Value Proposition PANDUIT Advisory Services FlexPod site readiness assessment services verify that all required Layer 1 Physical Infrastructure items are in-place, properly installed, and correctly configured to ensure a smooth, efficient, and successful FlexPod deployment and operation. 2

  3. Assess seven (7) key aspects of the data center physical infrastructure Power Thermal / Cooling Network Connectivity Pathways Space Floor loading Telecommunications Bonding Determine if each area is “ready to receive” a FlexPod – “Yes” or “No” For “No” areas, determine “level of fix” required and recommend improvement actions Provide written “Site Readiness” report PANDUIT Advisory Services Service overview What we do… 3

  4. PANDUIT Advisory Services Service overview Areas assessed… 4

  5. Assess 17 detailed aspects needed to properly power the desired FlexPod Specific to each FlexPod model Unique to each site’s FlexPod configuration Ensure proper equipment, POU, and room power configuration: Voltage Amperage (current) Frequency Single vs. 3-Phase Delta vs. Wye topology POU feeder plug style Determine if each item is 100% ready to power the FlexPod – if not, advise on needed upgrades or modifications PANDUIT Advisory Services FlexPod site readiness - Power What we do… 5

  6. PANDUIT Advisory Services FlexPod site readiness - Cooling What we do… • Measure 41 inter-related parameters to ensure proper thermal performance for the FlexPod • Overall layout and room conditions • Raised floor air handling capabilities • Overhead air return performance • Room-level or in-row cooling unit capacities and operating conditions • Recirculation or by-pass air issues • Target specific air temperature ranges, air flow speeds, and air volume numbers • Particular to each FlexPod model • Dependent on each site and FlexPod configuration • Verify that the data center can properly cool the FlexPod or if there will be thermal issues that require additional attention 6

  7. Confirm that the proper data communications links are available and ready to connect to the FlexPod Production data connections Management port channels Topology and redundancy Data cabling type, grade, and connector style Cable routing and pathways 36 point detailed assessment Get specific regarding port availability and channel counts Precise requirements for each FlexPod model, and individual configuration Detail needed improvements or additions Action plan for required modifications Data communications upgrade kits available PANDUIT Advisory Services FlexPod site readiness – Networking What we do… 7

  8. PANDUIT Advisory Services Engagement Fee 8

  9. Next Steps Discussion 9