An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. O.H. BauerMPE Garching PA/QA Status PA/QA Status

  2. PA/QA Status • Dr. W. Schmid started 01-Jan, replacing G. Igl • Improved common understanding, but still not satisfactory • ESTEC NCR system not really accepted • WE: For QM/FM FMECA, WCA, HSIA, FDIR should improve as now under industrial contract • CIDL/ABCL will be reworked according to agreed format • Overall FM schedule with MIP/KIP still missing • CIL has to be written • Agreement on FM EIDP layout needed soon PA/QA Status

  3. PACS Status • Warm Electronics • DPU • 1553 I/F: Burst mode works with ILT EGSE, but not with CCS CDMU-DFE Under investigation • Telemetry packets corrupted after random time (checksum error): 1553-1355 interferences NCR: 19/11/04 • SPU • Compression ratio still too low Work in progress • DECMEC • Many problems (H/W and S/W): FPGA, SMCS-2 DECMEC back to CSL for final repair Very critical ! • BOLC • Problem with non-graceful switch-off Work in progress • WIH Ok! PA/QA Status

  4. PACS Status II • FPU • Spectrometer Filterwheel • Could not be moved during cold ILT Problem found • Replaced by FM wheel, but without motor, in fixed position with ILT filter • Grating drive • Off-set of Zero position Solution for FM • Transformer box had to be added (at distribution board) to improve inductosync signal Solution for FM • Chopper • Envelope violation Solution for FM • Black Paint • Alodyne coating problem on two surfaces Paint removed from (paint peels off) several areas • No full qualification yet Critical! PA/QA Status

  5. PACS Status III • S/C Interfaces • Problems with all three L0 flexible links NRB needed • PACS requests short circuit connectors for all FPU connectors during all phases of cryo harness integration Astrium to react • EMC Test Results • PhFPU not compliant to RS-H requirement Re-open RfW-004 • DPU CE DM + Current Ripple on power lines non compliant NCR raisedRfW • SPU CE DM + Current Ripple on power lines non compliant NCR raisedRfW • ESD test not part of ILT  part of EQM Project to react PA/QA Status