1 / 8

HX-40/40AM

HX-40/40AM. 3.0m high mount outdoor detector . HX-40: standard model HX-40AM: HX-40 with active IR anti-masking model. confidential. Multiple pattern detection area technology with “Brand-New” pyro-element OPTEX developed a unique pyro-element to achieve high reliable detection performance.

inga
Download Presentation

HX-40/40AM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model HX-40AM: HX-40 with active IR anti-masking model confidential

  2. Multiple pattern detection area technologywith “Brand-New” pyro-element OPTEX developed a unique pyro-element to achieve high reliable detection performance By optimizing the horizontal to vertical ratio, HX series creates a sharp detection area. In addition, 94 high density detection zones provide an accurate discrimination function for spot temperature changes of a moving object. Conventional model HX series

  3. Intelligent AND logic A logic to prevent false alarms caused by a pet or small animal [this is effective to moving objects going toward to the detector] HX utilizes AND detection pattern technology – upper and lower detection areas have to be activated in order to generate an alarm condition. In addition, HX’s original area configuration adds width in between each detection area to prevent false alarms caused by a pet or small animal. Pet / Small animal : height 50cm, weight 10kg Conventional model HX series Conventional model HX series NO detection NO detection NO detection NO detection no detection no detection alarm alarm

  4. Sensitivity Sensitivity Temperature compensation sensitivity Time Ambient temperature Human body temperature Dual signal processing circuitBy automatically adjusting its detection sensitivity, HX prevents the missed alarms in a hostile environment • Summer night compensation logic • Summer evenings/nights and areas which are in shade can create environments where the difference between human body and the surrounding ambient temperature can be at its lowest point. Under these conditions the potential for a missed alarm can be greatly increased. The HX series addresses this issue by the additional measurement of luminance levels as the environment changes. The integration of temperature and additional luminance analysis provides the HX series with the ability to more accurately assess true environmental conditions and allows sensitivity to automatically sharpen as environmental conditions require. This combination greatly reduces the potential for missed alarms, whilst maintaining stability. • Advanced temperature compensation logic • It automatically increases the detector’s sensitivity under high temperature conditions, especially where the background temperature ranges from approx. 35 -37 degree C (95 - 98 degree F), close to that of the human body.

  5. Repetitive sensitivity Trigger level Trigger level Time Wave pattern from human body Wave pattern from swaying vegetation Vegetation sway analysis logicMonitors temperature change of the ground heated by daytime sunlight to prevent false alarms Wave pattern from vegetations and human body The temperature between the surface of bare ground and grass are uneven. Thus creating a distinctive wave change. HX monitors wave changes at all times and then automatically cancels the signal caused by swaying grass when it determines the increase of the distinctive wave change. Repetitive = 繰り返しの/反復的な

  6. Ideal detection area settingBy creating ideal detection patterns for specific applications, HX prevents the false and missed alarms • adjustable detection length • To limit the detection distance, apply the masking seal on the lens inside as in the figure. • spot area flexible masking • To limit the detection range, apply the area masking seal to the part you want to hide on the lens inside. Configure the area in such a way to avoid having anything cut across the area.

  7. Easy installation • Wiring space • Flexible adjustment (bracket) Under construction

  8. 180° angle adjustable bracket / hoodAppropriate installation achieves high quality performance Bracket: Using the bracket makes it possible to adjust 90°to the left and right. By achieving the accurate installation, false and missed alarms can be drastically reduced. Hood: This hood prevents the direct sun light getting into the lens. Also it maintains the detection ability by preventing the rain and frost covering the lens surface.