1 / 28

Mpcs la lte ho parameters trial

Mpcs la lte ho parameters trial. Overview. A study on the effect of handover parameters on the network performance will be done in a trial cluster (part of Cerritos)

Download Presentation

Mpcs la lte ho parameters trial

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Mpcs lalte ho parameters trial

  2. Overview • A study on the effect of handover parameters on the network performance will be done in a trial cluster (part of Cerritos) • The parameter change to be implemented as an iterative process with each drive and the results to be compared to analyze the effect of the parameters • Following parameters to be changed A3offset; hysteresisA3; filtercoefficientEutranRsrp; sMeasure; timetotriggerA3

  3. Review: LTE HO • Evaluates if one or more intra frequency cell is better than current serving cell • UE receives measurement configuration in RRC Connection Reconfiguration • No measurement list sent to UE (UE search for all 504 physical cell id and reports the cell(s) fulfilling the event criteria). • UE Event Trigger controlled by: – Filtering (How much averaging is done before event evaluation) – Offset (How much better in dB) – Time to trigger (For how long)

  4. Main Trigger Parameters • sMeasure = 0 { -140..-44, 0 } [dBm] Controlling if the UE is required to perform measurements. Disabled if set to “0” (used only RSRP is the trigger) • a3offset = 30 { -150..150 } [0.1 dB] Offset value for EventA3, added to serving cell • hysteresisA3 = 10 { 0..150 } [0.1 dB] Hysteresis value for eventA3, added to neighbor cell • timeToTriggerA3 = 40 { 0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640, 1024, 1280, 2560, 5120 } [ms] Time after Event A3 is fulfilled when UE starts to send Measurement reports • triggerQuantityA3 = RSRP [RSRP,RSRQ] The quantity that triggers the event • cellIndividualOffsetEUtran Offset value specific to a neighbor relation

  5. Handover Filtering • To avoid that the measurement reporting is triggered by fast fading, the measurement configuration contains filter coefficient for the UE to use • filterCoefficientEUtraRsrp = 9{ 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19 } Filter coefficient for RSRP measurements • filterCoefficientEUtraRsrq = 11{ 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 13, 15, 17, 19 } Filter coefficient for RSRQ measurements

  6. Event A3: A neighbour cell(b) becomes offset better than serving cell(a)

  7. Drive Info

  8. Trial Cluster – Drive Route

  9. Baseline Test Cases

  10. Baseline Test Cases (contd) • Baseline2 drive demonstrated the highest number of handovers and the smallest delta in RSRP/RSRQ.

  11. Baseline Test Cases (contd) • Baseline drive demonstrated the best SINR performance.

  12. A3offset Test Cases

  13. A3offset Test Cases (contd) • There was a clear decrease in the number of handovers and an increase in the RSRP/RSRQ delta as went from a3offset=0 to a3offset=40. • This is expected as the sum of hysteresisA3 and a3offset increases. Notice, as expected, Delta RSRP ~ hysteresisA3+a3offset.

  14. A3offset Test Cases (contd) • Baseline (smallest offset) demonstrated the best SINR performance.

  15. HysteresisA3 Test Cases

  16. HysteresisA3 Test Cases (contd) • There was a clear decrease in the number of handovers and an increase in the RSRP/RSRQ delta as went from hysteresisA3=20 to hysteresisA3=80. • This is expected as the sum of hysteresisA3 and a3offset increases. Notice, as expected, Delta RSRP ~ hysteresisA3+a3offset.

  17. HysteresisA3 Test Cases (contd) • hysteresisA3=20 (smallest hysteresis) demonstrated the best SINR performance.

  18. TimeToTriggerA3 Test Cases

  19. TimeToTriggerA3 Test Cases (contd) • Number of handovers decreased and RSRP/RSRQ delta increased with the increasing timeToTrigger. This is as expected.

  20. TimeToTriggerA3 Test Cases (contd) • timeToTriggerA3=0 and Baseline(40) demonstrated the best SINR performance.

  21. FilterCoefficientEutraRSRP Test Cases

  22. FilterCoefficientEutraRSRP Test Cases (contd) • Number of handovers decreased and RSRP/RSRQ delta increased with the increasing filterCoefficientEUtraRsrp. • This is as expected as the number of measurement samples analyzed for each handover increases.

  23. FilterCoefficientEutraRSRP Test Cases (contd) • Baseline gave the best SINR performance.

  24. sMeasure test cases

  25. sMeasure test cases (contd) • No apparent trend was observed between these drives.

  26. sMeasure test cases (contd) • The effect of sMeasure parameter on the network is inconclusive in regards to the performed drives.

  27. Summary • Tested parameters for the most part resulted in the expected behavior: • Number of Handover events. • RSRP/RSRQ delta upon Handover. • Pre-handover SINR performance. • Part of the unexpected behavior can be attributed to the variation in drive test setup between some of the drives. • The effect of sMeasure parameter on the network is inconclusive at this point. It will be further analyzed during the testing on DAS nodes. • Current Baseline is pretty suitable to the network at this early stage of operation. It is recommended that optimization, when performed, be performed on a case by case basis.

  28. THANK YOU