An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Performance Measurements ofLANs MANs and SuperJANET III This is PRELIMINARY • Baseline data for Grid development • Latency • Throughput / Bandwidth • Packet Jitter • Performance of 2 Mbit Managed Bandwidth Link • TCP/IP Stream performance July 2000PPNCG Meeting R. Hughes-Jones

  2. PC software 0.01 ms/byte Sun software 0.036 ms/byte Latency • Round trip times measured using Request-Response UDP frames • Latency as a function of frame size • Slope gives sum of individual data transfer rates end-to-end • Histograms of individual measurements • On LAN Latency histograms ~ 2 ms wide July 2000PPNCG Meeting R. Hughes-Jones

  3. Sigma ~12 ms Latency: Man-DL • ATM MAN • 7 routers ~0.8ms / router • Router+link 0.4 ms/byte • DL-Liv ~10 ms rtt - agreement July 2000PPNCG Meeting R. Hughes-Jones

  4. Latency: Man-IC • Sigma decreases with size 3.4 -> 1.7 ms • Packet loss falls 5 -> 1 % July 2000PPNCG Meeting R. Hughes-Jones

  5. Latency: Man-UCL • Slope 1.84 ms/byte • Sigma decreases with size 3.7 -> 1.7 ms • Packet loss falls 3 -> 1 % July 2000PPNCG Meeting R. Hughes-Jones

  6. DL slope 2.5 ms/byte cf min time slope 1.5 ms/byte Latency: Man-GLA • Sigma decreases with frame size 2.6 -> 2.3 ms • NO Packet loss July 2000PPNCG Meeting R. Hughes-Jones

  7. Latency: Man-RAL • Sigma 4.5 -> 6.7 ms • NO Packet loss July 2000PPNCG Meeting R. Hughes-Jones

  8. Latency: Man-RAL Managed BW • 5 routers ~0.8ms / router • Slope 6.5 ms/byte • A 2Mbit link uses 4 ms/byte • NO Packet loss • Sigma ~ 2.0 ms • Sigma 4.5 ->6.7 ms July 2000PPNCG Meeting R. Hughes-Jones

  9. Latency: Man-MC • Pink main campus router • Blue NNW – SuperJANET • Nice exponential - queuing July 2000PPNCG Meeting R. Hughes-Jones

  10. Zero stats OK done Send data frames at regular intervals ●●● ●●● Time to send Time to receive Get remote statistics Send statistics Bandwidth • Send a burst of UDP frames spaced at regular intervals • Vary the frame size and the frame transmit spacing • Record • The time to send and the time to receive the frames • The number received, the number lost, number out of order July 2000PPNCG Meeting R. Hughes-Jones

  11. Bandwidth: Man-DL • ATM MAN • 10 Mbit link into the ICFA PC • No frames lost when not queuing July 2000PPNCG Meeting R. Hughes-Jones

  12. Bandwidth: Man-IC • NNW – ATM WAN – London Man • 1-2% frame loss when not queuing for all frame sizes July 2000PPNCG Meeting R. Hughes-Jones

  13. Bandwidth: Man-UCL • NNW – ATM WAN – London Man • Suspect a 10 Mbit link at UCL • 1-2% frame loss when not queuing for all frame sizes • IC-UCL frame loss ~0.1% July 2000PPNCG Meeting R. Hughes-Jones

  14. Bandwidth: Man-GLA • NNW – ATM WAN – Glasgow • NO frame loss when not queuing • Similar behavior to Man-IC July 2000PPNCG Meeting R. Hughes-Jones

  15. Bandwidth: Man-RAL • PC Manc. – NNW – ATM WAN – LAN RAL Sun • Odd bursts of frame loss when not queuing • 24 Mbit link into RAL July 2000PPNCG Meeting R. Hughes-Jones

  16. Bandwidth: Man-RAL Managed BW • PC Manc. LAN – ATM PVC – RAL Sun • NO frame loss when not queuing • Suggests PVC iS CBR, given 1 cell every 75 July 2000PPNCG Meeting R. Hughes-Jones

  17. Packet Jitter • Same protocol as for the Throughput tests • Send frames at regular fixed time intervals • Measure the difference between consecutive frame arrivals using the Pentium cycle counter. July 2000PPNCG Meeting R. Hughes-Jones

  18. Packet Jitter: Man-MC PRELIMINARY !! • HEP – gw-metro • Major peaks 160 ms • Satellites  40 ms • ATM cell 2.74 ms ? • 1000 byte frames appear to arrive too quickly. July 2000PPNCG Meeting R. Hughes-Jones

  19. Packet Jitter: IC-UCL PRELIMINARY !! • 1000 ms frame spacing • Structure for 100 byte frames • Satellites at  40 ms • ATM cell 2.74 ms ? July 2000PPNCG Meeting R. Hughes-Jones