Status of development on silicon telescope for nanodosimetry
Sponsored Links
This presentation is the property of its rightful owner.
1 / 22

Status of Development on Silicon Telescope For Nanodosimetry PowerPoint PPT Presentation


  • 52 Views
  • Uploaded on
  • Presentation posted in: General

Status of Development on Silicon Telescope For Nanodosimetry. Santa Cruz Institute For Particle Physics University of California, Santa Cruz. Definition of Work. Mechanical Integration: ASIC’s on MCM’s Connector on MCM SSD’s and MCM’s Modules in Vessel Electronic Integration:

Download Presentation

Status of Development on Silicon Telescope For Nanodosimetry

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Status of Development on Silicon Telescope For Nanodosimetry

Santa Cruz Institute For Particle Physics

University of California, Santa Cruz


Definition of Work

  • Mechanical Integration:

    • ASIC’s on MCM’s

    • Connector on MCM

    • SSD’s and MCM’s

    • Modules in Vessel

  • Electronic Integration:

    • Layout of MCM

    • Link Between Module and SSD

    • Link Between Module and DAQ

      • Cables and Connectors


Components of Telescope


Components of Telescope


Module Frame


Module Overview

.8

2.7

PCB

10cm

9.1

6.4


Components of Telescope


GLAST Tracker


Wire Bonding


One Detector


LLU MCM

2560 mil

6.5 cm

1375 mil

3.5 cm


Components of Telescope


Cable

Vessel/DAQ

Front Board

Back Board


Minimizing Errors

  • Mechanical errors

    • Spatial conflict

    • Out-gassing

    • Pressure(explosion/implosion)

  • Data errors

    • Use Identical DAQ

    • Test MCM with charge injection


Minimizing Errors

  • Avoid Mechanical errors

    • Spatial conflict

    • Out-gassing

    • Pressure(explosion/implosion)

      • How big do ventilation holes need to be?

  • Avoid hardware errors

    • Use Identical DAQ

    • Test MCM with charge injection


= Air Hole


Minimizing Errors

  • Calibration/ Readout Errors

    • Patrick will discuss this subject


Schedule


Schedule


Schedule


  • Login