1 / 5

Transformer oil manufacturer in Indiia

Here we are defining an article to introduce how transformer oil is manufactured. A huge aspect shielded oil in which winding of wide power transformer are periodically consumed to produce high-dieletric strength , high insulation resistance, high critical movement, exception from moisture, and freedom from decomposition.<br><br>To know more information visit http://powerlinkoil.com/transformer-oil/<br><br>

gomes
Download Presentation

Transformer oil manufacturer in Indiia

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Transformer oil Manufactured Here we are defining an article to introduce how transformer oil is manufactured. A huge aspect shielded oil in which winding of wide power transformer are periodically consumed to produce high-dieletric strength , high insulation resistance, high critical movement, exception from moisture, and freedom from decomposition. The manufacturing process of Transformer oil cover below lited activities.  Coil Winding  Core Assembly  Core-Coil Assembly  Tank-up  Transformer Tank  Painting and Finishing source: Transformer oil

  2. Core Winding is of two types: 1. High Voltage Coils: High Voltage Coil are the component of Transformer. Generally round insulated wire either of Copper (Cu) or Aluminium (Al) is used as basic raw material. The coils are made in Number of Layers. The starting and ending leads of each coil are terminated on either side of the coil. 2. Low Voltage Coil: Low Voltage Coil are also component of Transformer. Core Assembly  It is in the pattern of thin sheets & cut to size as per design.  Nothing is performed to increase the magnetic path.  The lamination are put through toughen process.  The entire gathering is done on a frame commonly known as core channel. source: Automotive oil

  3. Coil-Core Assembly The constituent yield in the coil winding and core assembly stage are then captured into core- coil assembly stage. The core assembly is from side to side settled with the foot plate moving emotionally the ground. The top bond of the core is detached. The limbs of the core are firmly protected with cotton tap and varsed. Cylinder is manufactured out of insulating particle board or wood product is enveloped on all the three limbs. Low Voltage Coil is deposited on the insulated core limbs. Insulating block of detailed thickness and number are located both at the top and bottom of the Low Voltage Coil. Cylinder built out of folded paper with oil canel are provided over Low Voltage Cil. High Voltage Coils are located over the cylinder. Goap between each unit of High Voltage Coils inclusive top and bottom clearance is maintained with the help of oil particle board, as per the the design. The top chain is refresh. Top core frame consist of core bolts and tie rod are fixed in position. Primary and secoindary winding are established as per the needs. Phase boundary between High Voltage phases are located as per needs. Connections to the tapping switcy are provided if required. Finally, the component is placed in the oven. source: Industrial oil

  4. Tank Up The core-coil mass and tank equipped by the fabrication department are tank-up stage. The conduct is: The core-coil cluster is take? out of the ove? a?d the ?Megger test?,?i.e., a? i?stru?e?t that ge?erates a high voltage i? order to test resista?ce of i?sulatio?? is carried out. Only if the megger value is as per the specification, the mass may be taken for tank-up. The tanks, given by fabrication department are brought up to tank-up department which is duly painted. Proper fittings like drain valves, high voltage and low voltage cylinder, conservator, oil level pointer are equipped in the tank. Connections of primary and secondary to the terminal cylinder are made. source: Coolants

  5. Transformer tank We have ability to maunfacturer transformer tanks. All tanks are made up of huge quality steel. Painting The entire process includes two steps:  Cleaning  Painting Finishing Proper fittings and all accessories as per customer requirements are checked. source: Defense Grade Products

More Related