1 / 12

Columbia U Comp-X General Atomics INEL Johns Hopkins U LANL LLNL Lodestar MIT Nova Photonics NYU

Direct Measurement of MHD-induced Fast-ion Redistribution in Space and Energy by NPA Vertical Scanning. Columbia U Comp-X General Atomics INEL Johns Hopkins U LANL LLNL Lodestar MIT Nova Photonics NYU ORNL PPPL PSI SNL UC Davis UC Irvine UCLA UCSD U Maryland U New Mexico

gali
Download Presentation

Columbia U Comp-X General Atomics INEL Johns Hopkins U LANL LLNL Lodestar MIT Nova Photonics NYU

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Direct Measurement of MHD-induced Fast-ion Redistribution in Space and Energy by NPA Vertical Scanning Columbia U Comp-X General Atomics INEL Johns Hopkins U LANL LLNL Lodestar MIT Nova Photonics NYU ORNL PPPL PSI SNL UC Davis UC Irvine UCLA UCSD U Maryland U New Mexico U Rochester U Washington U Wisconsin Culham Sci Ctr Hiroshima U HIST Kyushu Tokai U Niigata U Tsukuba U U Tokyo JAERI Ioffe Inst TRINITI KBSI KAIST ENEA, Frascati CEA, Cadarache IPP, Jülich IPP, Garching U Quebec S. S. Medley XP707 Review PPPL, February 8, 2007

  2. The Neutral Particle Analyzer (NPA) on NSTX ScansVertically Over a Wide Range of Angles on a Shot-to-Shot Basis The elevation minor radius at the intersection of the NPA sightline with a given neutral beam line depends on the NPA horizontal tangency radius.

  3. TRANSP Anomalous Fast Ion Diffusion (AFID) Can Simultaneously Match Sn(t), Snpa(t) and fnpa(E) • In TRANSP, AFID can be specified in space, time and fast-ion energy. ne(au)

  4. NPA Vertical Scan Can Measure MHD-induced Spatial Redistribution of Energetic Ions Without AFID With AFID •TRANSP simulation (119768M22) of NPA vertical scan without anomalous fast ion diffusion (left) and with core-weighted anomalous fast ion diffusion (right). •At E > E/2, on-axis ions are depleted and redistributed outward by ~ 20 cm.

  5. Target Discharge Characteristics (Part I: MHD Aactivity with f < 200 kHz) •Long pulse H-mode (t ~ 1 s) with A, B, C @ 90 keV. •Stable outer gap ~ 5-10 cm early in discharge and ne(r) ‘flattop’ after t ~ 0.5 s. •Wide range of reproducible *AE and MHD activity with a quiescent period ~ 100 ms. •Strong depletion of the NPA energetic ion spectrum down to E/3.

  6. Target Discharge Characteristics (Part II: MHD Activity with f > 200 kHz) •Long pulse H-mode (t ~ 1 s) with A, B, C @ 90 keV. •Stable outer gap ~ 5-10 cm early in discharge and ne(r) ‘flattop’ after t ~ 0.5 s. •Quiescent phase for f < 200 kHz at t > 0.7 s with continuing activity at f > 200 kHz. •Strong depletion of the NPA energetic ion spectrum down to E/3.

  7. XP Scan Details √ Exploit expanded diagnostic coverage - sFLIP (image capture for full t ~ 1 s discharges) - multi-color USXR (profile inversion for mode location) - faster NPA data acquisition (t ~ 0.1 ms) - ssNPA (simultaneous 4-chord mid-plane profile) √NPA vertical scanning requires removal of the Lithium Pellet Injector

  8. Scope Waveforms: 117449

  9. Scope Waveforms: 119768

  10. Scope Waveforms: 119613

  11. Scope Waveforms: 120001

  12. Scope Waveforms: 119992