1 / 11

Recommendations to develop Gen. 2 CFD mesh for Spray G

This document provides recommendations for developing a second-generation CFD mesh for spray G, including specified geometry features and orientation convention. Additionally, it discusses the limitations of X-ray tomography measurements and compares the results to optical microscopy. Technical accomplishments and further analysis are also presented.

gabrielleg
Download Presentation

Recommendations to develop Gen. 2 CFD mesh for Spray G

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recommendations to develop Gen. 2 CFD mesh for Spray G Julien Manin Lyle Pickett

  2. List of features “Specified” geometry with “open” pintle/ball 6 10 8 • Inner hole inlet diameter after inlet radius 3 • Inner hole exit diameter before exit radius 4 • Inner hole inlet radius of curvature • Inner hole exit radius of curvature • Inner hole length • Inner hole drill angle relative to injector axis • Outer hole inlet diameter after inlet radius 9 • Outer hole exit diameter before exit radius 10 • Outer hole inlet reverse radius of curvature • Outer hole exit radius of curvature • Outer hole length 9 7 4 3 2 11 1 5

  3. Spray G orientation convention • We decided to use the SAE J2715 as guidelines for the orientation of the Spray G injector (Different from Spray A) • The hole numbering is done clockwise from the front view of the injector (facing the spray tip)

  4. X-ray tomography measurements • Two datasets have been obtained for injector 28 using x-ray tomography measurements: • ESRF – 1.325 µm resolution • Northstar imaging – 5.07 µm resolution – STL • Unfortunately, the data from the ESRF cannot be processed to extract detailed information about internal geometry

  5. Comparison to optical microscopy • Optical microscopy provides relatively accurate measurement of outlet equivalent diameter • But the measurements only consider the very exit of the orifice • Problematic when the orifice is cylindrical or inversely tapered • The optical microscopy measurements show larger quantities than the x-ray-derived STL data • X-ray tomography shows that the minimum hole diameter is slightly smaller than the value measured near the exit

  6. Inner hole mean shows a slight (3 um) divergence once “settled” inside hole to the exit.

  7. Technical Accomplishments Understanding sources of plume-to-plume dispersion and plume-to-plume interaction (Spray G) • Top plumes appear to penetrate more quickly, at least initially • In agreement with atmospheric patternation and imaging performed at Delphi for the same injector (#28) Ambient 15 bar 9 kg/m3 5.8 bar 3.5 kg/m3 Front-View Mie-scatter Spray G

  8. Hole size accounts for some variance between plumes optical microscopy of inner hole • x-ray min. • commercial x-ray tomography • optical

  9. Not much change in outer hole to justify a change from spec.

  10. Further analysis • The radius of curvature at the entrance and exit of the flow orifice is paramount to the flow • The ESRF data reject the specifications in that respect • The Northstar STL is definitely under-resolved to accurately describe these parameters R80 • The Northstar data can be used to extract hole drill angle information • Angles roughly vary from 34 to 39o(specification is 37o) • At the same time, the angle values are highly uncertain because of the short orifice length

  11. Geometry recommendations

More Related