Flow Data. Sample data taken from Nov 3 to Nov 19. Inflow vs. outflow. Outflow consistently greater than inflow (for both sunny and rainy days with steady cell height) Instrument error or other unidentified input?. Recirculation. Abnormal F1. Surge. Normal F1. Problem of F1 reading.

Download Presentation

Flow Data

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Flow Data

  • Sample data taken from Nov 3 to Nov 19


Inflow vs. outflow

  • Outflow consistently greater than inflow (for both sunny and rainy days with steady cell height)

  • Instrument error or other unidentified input?


Recirculation

Abnormal F1

Surge

Normal F1

Problem of F1 reading


Magnetic meters


From F2 to F3 to M4

  • M4 should be less than F2 and F3


Discharge From Water Softer Building to LS4


Recirculation

Abnormal F1

Surge

Normal F1

F1 consistent with surge tank except during recycle. Backflow problem exists.


Expected Errors with open channel flow meters


Sampling Points

Effluent

LS-4

M-4

ST-1

ST-2

(To city)

AS-2

LS-1

F-1

AS-1

M-1

AS-4

LS-3

F-3

ACT-1

M-3

W-3

Wetland Cell

(W-1)

Wetland Cell

(W-2)

Recirculation

Biofield

ACT-2

LS-2

LS-2

M-2

F-2

FS

N

Not to scale

AS-3

Weather station

Lift station/Dosing Chamber

V notch weir Flow meter

Flume Flow meter

Automatic Sampling Station

Magnetic Flow meter

Flow splitter

Surge Tank


Wetland Performance


Wetland Performance

  • Continuing sample analysis

  • Samples taken from Surge Tank in Oct. & Nov.

  • Chlorine Test performed in October


Wetland Performance

  • Chlorine Test

    • Sample analyzed from AS-2

    • DPD Titrimetric test: positive results

  • Oxidizing agents (Chlorine or other products) may be present in waste stream

    • Found in antibacterial soaps, cleaning supplies

    • Possible cause for stress to plants


Upcoming Work

  • DPD Colorimetric test

    • Can determine quantity of oxidizing agent present

    • To be done at more sampling points

  • Are septic tanks working properly?

    • Biodegradation occuring, or

    • Settling system, oxidants bypass

    • DPD test will give insight