K800 FIT
This presentation is the property of its rightful owner.
Sponsored Links
1 / 30

K800 FIT PowerPoint PPT Presentation


  • 106 Views
  • Uploaded on
  • Presentation posted in: General

K800 FIT. Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats. Terminals Features – Heater. Provides reliable operation in the coldest climates. Terminals Features – Receipt Printer. Thermal On Demand Receipts Customizable Header, Trailer, & Body (proprietary only).

Download Presentation

K800 FIT

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


K800 fit

K800 FIT

Fuel Island Terminal (Hybrid)


Terminals features identity formats

TerminalsFeatures – Identity Formats


Terminals features heater

TerminalsFeatures – Heater

Provides reliable operation in the coldest climates


Terminals features receipt printer

TerminalsFeatures – Receipt Printer

Thermal

On Demand Receipts

Customizable Header, Trailer,

& Body (proprietary only)

02/10/99 12:37 PM

CARD #1: 0300000000000001

CARD #2: 0300000000000002

TRANS #: 46

PRODUCT: UNLEADED

QUANTITY: 40.000

PR/UNIT:$ 1.290

TOTAL: $ 51.60

DRIVER: MR ED

ACCT.NAME: ACME TRUCKING

SITE I.D.: 1

MISC: 54785

ODOM: 22345

M.P.G. 4.7

PUMP #: 1 - 1

ACCOUNT#: 1000


K800 fit pct w fsc3000 hybrid

K800 FIT/PCT w/ FSC3000 (Hybrid)

Requires K800 FIT software 21.01H or up

All FSC3000s Sys2 requires

FSC software 21.01D/33.07 or up

Petro-Net is fixed at 9600

PCT is integrated with the FIT

(FIT 1 is PCT 1, FIT 4 is PCT 4, Etc.)

No Receipt Printer


K800 fit

Fuel Island Terminal (FIT) Features

Built-In Diagnostics

Simplified trouble-shooting

Up to 4 Terminals Supported

Each FIT controls up to 4 fueling points simultaneously

(Max. 16 fueling points)


K800 fit

K800 Fuel Island Terminal (FIT) Overview


K800 fit

FIT Power & Communication Wiring

OR

Outdoors

Indoors

FIT Power and Petro-Net Wires

Peripheral

Power Outlets

Circuit

Panel

Petro-Net Junction Box

Petro-Net can be wired as Star or daisy chain


K800 fit

FIT Pump & Pulser Conduit & Wiring

Existing Conduit

New Conduit

Pumps

Pumps

Pump Junction Box

Outdoors

Pump Power and Pulser Wires

Indoors

Circuit

Panel

Wiring Trough


Fsc3000 controller features and benefits

FSC3000 ControllerFeatures and Benefits

Compatible with System2 components

System2 FITs, PCTs

Configurable with Windows-based software

Command-Line Programming

Store up to 2000 transactions


Fsc3000 controller capabilities

FSC3000 ControllerCapabilities

Downloadable Firmware & Option Upgrades

Optional Built-in Dial-in Modem

Standard Built-in Ethernet

Office journal printer for transaction backup

Support Wireless Communications to Terminals


Fsc3000 controller local proprietary record features

FSC3000 ControllerLocal Proprietary Record Features

Single or Dual-Entry (Driver & Vehicle)

Account Grouping

Restrictions – Product, Quantity, Allocations, Reasonability

Personal Identification Number (PIN)

Supports over 60,000 Records (9999 accounts)

Odometer Tracking

Additional Programmable Prompts

Alphanumeric, verified


Fsc3000 controller network capability

FSC3000 ControllerNetwork Capability

Dial-out to up to 8 different networks

Comdata

T-Chek

FleetOne

TCH

EFS

Paymentech

Credit Cards

Wright Express

Voyager

Fuelman

CFN

NBS

Dual-Host Authorization

Registered Bank Card


Fsc3000 controller reporting features

FSC3000 ControllerReporting Features

PUMP #1

TOTALS: 512.5

TOTALIZER: 512.5

PUMP #2

TOTALS: 1154.0

TOTALIZER: 1154.0

PUMP #3

TOTALS: 1158.7

TOTALIZER: 1158.7

PREMIUM QTY: 11748.0 GALLON

UNLEADED QTY: 10900.0 GALLON

REGULAR QTY: 10000.0 GALLON

MRKD FUEL QTY: 11748.0 GALLON

#1 DIESEL QTY: 10900.0 GALLON

#2 DIESEL QTY: 10000.0 GALLON

GASOHOL QTY: 11748.0 GALLON

ALCOHOL QTY: 10900.0 GALLON

Pump an Product total reports

Declining Inventory Report

Midnight Totals

TANK #1 PREMIUM QUANTITY: 11748.0 LOW LEVEL: 2000.0

TANK #2 UNLEADED QUANTITY: 10900.0 LOW LEVEL: 2000.0

TANK #3 REGULAR QUANTITY: 10000.0 LOW LEVEL: 2000.0

TANK #4 MRKD FUEL QUANTITY: 11748.0 LOW LEVEL: 2000.0

TANK #5 #1 DIESEL QUANTITY: 10900.0 LOW LEVEL: 2000.0

TANK #6 #2 DIESEL QUANTITY: 10000.0 LOW LEVEL: 2000.0

TANK #7 GASOHOL QUANTITY: 11748.0 LOW LEVEL: 2000.0

TANK #8 ALCOHOL QUANTITY: 10900.0 LOW LEVEL: 2000.0


Artware windows base configuration tool

ARTWare Windows-base configuration tool

Simplifies Configuration

Off-line or On-line

Global database for common site parameters

Separate databases for different customers


Terminals features

TerminalsFeatures

With the ART system the customer can choose one of our 3 terminals to meet the his needs.

K800 Hybrid FIT

Fuel Island Terminal

C/OPT

Commercial Outdoor Payment Terminal

FIT500

Fuel Island Terminal


Terminals features1

TerminalsFeatures

Support for up to 8 terminals.

Pump Restriction to specific terminals


Pump control features

Pump ControlFeatures

The FSC3000 is capable of controlling up to 32 fueling points. The system can control both mechanical and electronic pumps or a combination of them.

Note:

With electronic pumps there may a hardware limitation that may decrease the number of fueling points that can be controlled.


Pump control features1

Pump ControlFeatures

Time-Outs

Handle, First Pulse, Missing Pulse (MPD), Total Fueling

Configurable Pulse per unit

Pump Sentry

Product Restrictions

Hose restrictions on multi-product dispensers

when using DPC or UPC option is used


Pump control methods

Pump ControlMethods

Mechanical Pump Control by Pump Control Module (PCM)

or K800 Hybrid Integrated Pump Control

Note: Pump Control Terminal (PCT) no longer sold with new systems still exist in large numbers

Electronic Pump Control by Universal Pump Control (UPC)

using manufacture’s console or pump controller

Electronic Pump Control by Direct Pump Control (DPC)

Controlling pumps directly


Art system functional overview

ART SystemFunctional Overview

1) Driver inserts his card

2) System prompts for additional information (PIN #, Mileage, etc.)

3) Driver selects his pump #

4) Driver begins fueling his vehicle

5) When finished driver reinserts his card and gets receipt.


K800 fit

FSC3000

Fuel Site Controller

Specifications / Components

LEDs, Switch &

Jumper Settings

Power & Peripheral

Connections

Installation

Cold Start Procedure


K800 fit

FSC3000

Front/Back View


K800 fit

FSC3000

Inside View

Warning: This contains high voltage inside the unit and should be unplugged when servicing


K800 fit

DPC

Direct Pump Control

With the ART system you are now able to control

electronic pumps without having the additional hardware required with a UPC.


Dpc electronic pump control

DPC - Electronic Pump Control

Supports the following Brands

Gilbarco, Tokheim, Wayne

32 Fueling Points (may be hardware limitations)

Directly interfaces to pump distribution boxes


Dpc gilbarco

DPCGilbarco


Dpc tokheim

DPCTokheim


Dpc wayne

DPCWayne