1 / 43

Foam Firefighting

Foam Firefighting. Section IV Foam Application and Operations. Objectives. Discuss the principals and considerations for fighting Class A fires. Dispel myths surrounding Class A foam Discuss Class A Foam for structural fire attack.

flynn
Download Presentation

Foam Firefighting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Foam Firefighting Section IV Foam Application and Operations Colleton County Fire-Rescue Training Division

  2. Objectives • Discuss the principals and considerations for fighting Class A fires. • Dispel myths surrounding Class A foam • Discuss Class A Foam for structural fire attack. • Discuss the effectiveness of Class A foam for exposure protection. Colleton County Fire-Rescue Training Division

  3. Objectives • Discuss Class A foam’s benefits during overhaul. • Define the principals of Class B fire attack. • Discuss the techniques of Class B foam application. Colleton County Fire-Rescue Training Division

  4. Objectives • Discuss considerations for after foam is applied • Discuss the strategies for exposure protection for Class B fire incidents. • Discuss water supply considerations. Colleton County Fire-Rescue Training Division

  5. Principals and Considerations for Fighting Class A Fires • Class A foam is biodegradable when used in small ratios of .01-1.0%. • Considerations should still be made to keep runoff out of sewers lakes and streams. • Use proper PPE when handling concentrates. Colleton County Fire-Rescue Training Division

  6. Principals and Considerations for Fighting Class A Fires • Clean PPE thoroughly if it has been soaked in concentrates. • Have backup lines in operation when high energy foam systems are in use. • Foam proportioning ratios can be tailored to suit the job. Colleton County Fire-Rescue Training Division

  7. Class A Foam Common Myth Some people have promoted the theory that 200 of a foam solution aspirated to a 10:1 expansion ration actually gives you the fire protection capability of 2,000 gallons of water. False Colleton County Fire-Rescue Training Division

  8. Class A Foam Myth Dispelled • Class A foam only makes water more efficient at soaking into the fuel and absorbing heat. • Less water is required to extinguish a fire than if plain water is used. • It does not create more water!!! Colleton County Fire-Rescue Training Division

  9. Class A Foam Common Myth Foam lines may be flowed at lower application rates or from smaller hose lines than those of plain water. False Colleton County Fire-Rescue Training Division

  10. Class A Foam Myth Dispelled • There is no reputable scientific data to prove this point. • Shorter discharge times results in less water being used. • It is recommended that foam solution flow rates and hose sizes be the same as the generally accepted flow rates and hose sizes for plain water. Colleton County Fire-Rescue Training Division

  11. Class A Foam and Structural Fire Attack • Most effective on interior fire attacks. • Must be applied directly to the burning material to be most effective. • Helps maintain visibility due to less steam conversion. Colleton County Fire-Rescue Training Division

  12. Class A Foam and Structural Fire Attack • When using Class A foam for an interior attack use with either a direct or combination attack. • Reduces time a fire stream needs to be applied. Colleton County Fire-Rescue Training Division

  13. Class A Foam and Structural Fire Attack • Fog nozzles should be used on low energy foam lines. • Fog or smoothbore nozzles may be used with CAFS systems. Colleton County Fire-Rescue Training Division

  14. Class A Foam and Structural Fire Attack • CAFS fire streams are well suited for exterior fire attacks. • The extended reach assures that the foam is being delivered deep into the structure. • The fire can be knocked down quickly from a window or a doorway. Colleton County Fire-Rescue Training Division

  15. Class A Foam and exposure Protection • Excellent for protecting exposures. • Insulating properties protect unburned areas. • Type 2 or Type 3 foam is recommended Colleton County Fire-Rescue Training Division

  16. Class A Foam Overhaul Operations • Class A foam exhibits some of it’s greatest benefits during overhaul operations. • Applied in the same fashion as water with standard nozzles and techniques. Colleton County Fire-Rescue Training Division

  17. Class A Foam Overhaul Operations • Drastically reduces the amount of water used. • Limited runoff • Less water damage Colleton County Fire-Rescue Training Division

  18. Class A Foam Overhaul Operations • Thermal blocking occurs when concealed hot spots contain enough heat to turn small amounts of penetrating water into steam. Colleton County Fire-Rescue Training Division

  19. Class A Foam Overhaul Operations • The use of foam helps defeat the phenomenon of thermal blocking by enabling more water to penetrate deeper and speed the cooling process. Colleton County Fire-Rescue Training Division

  20. Principals of Class B Fire Attack. • Size of the fire • Type of fuel • Required application rate • Amount of foam concentrate needed and available • Ability to deliver and sustain the required foam rate Colleton County Fire-Rescue Training Division

  21. Size of the Fire • Almost always involve the entire surface of an exposed fuel. • May remain that size throughout the duration of the incident. • Coincidently the size of the fire is fairly constant throughout the incident. Colleton County Fire-Rescue Training Division

  22. Size of the Fire Determining the size of the fire in a circular enclosure in square feet. Area = 3.14 X Radius² Determining the size of the fire in a square or rectangular enclosure in square feet. Area = Length X Width Colleton County Fire-Rescue Training Division

  23. Size of the Fire If the Fire Involves a Spill Area • Determine the maximum length and width of the spill and multiply by those numbers Colleton County Fire-Rescue Training Division

  24. Type of Fuel • Hydrocarbon • Polar Solvent • Toxic or Non Toxic • Water Reactive Colleton County Fire-Rescue Training Division

  25. Application Rate Sq ft (X) 0.1 for Hydrocarbons = Application Rate in GPM Sq ft (X) 0.2 for Polar Solvents = Application Rate in GPM Colleton County Fire-Rescue Training Division

  26. Amount of Foam Concentrate Application Rate (In GPM) X Discharge time (15 min) X Proportioning Rate (.03 or .06) = Concentrate Required Colleton County Fire-Rescue Training Division

  27. Ability to Deliver and Sustain the Required Foam Rate • Have enough foam on hand • Have enough water • GPM (X) 15 min (–) Concentrate Required = Water Required • Have the proper equipment to flow the required application rate. Colleton County Fire-Rescue Training Division

  28. Techniques of Class B Foam Application. • Air Aspirated Foam • Non Air Aspirated Colleton County Fire-Rescue Training Division

  29. Air Aspirated Foam Advantages • Foam is longer lasting. • Longer drainage time. • Highest quality. Colleton County Fire-Rescue Training Division

  30. Air Aspirated Foam Disadvantages • Short Reach • Affected by wind conditions • Nozzles can be bulky and may be single purpose. Colleton County Fire-Rescue Training Division

  31. Non Air Aspirated Foam Advantages • Can be applied through any standard fog nozzle. • Greater reach and penetrating power • Faster knockdown in lab tests. Colleton County Fire-Rescue Training Division

  32. Non Air Aspirated Foam Disadvantages • Will not form as thick of a blanket. • Requires more frequent re-application. Colleton County Fire-Rescue Training Division

  33. Manual Application Techniques • Roll On Method (roll foam onto leading edge of spill or fire and roll foam toward the back). • Bank Down Method (hit an elevated object above the spill or fire). • Rain Down Method (foam is sprayed above and is rained down on spill or fire). Colleton County Fire-Rescue Training Division

  34. Exposure Protection • Not different from structural fire exposure protection. • Judgmental decision based on the situation. Colleton County Fire-Rescue Training Division

  35. After Foam is Applied • Protect your foam blanket at all costs. • Insure that no smoking or other sources of ignition around the blanket. • Insure that blanket is not broken, walked or driven through. • Insure that your hoses are not part of the spill. Colleton County Fire-Rescue Training Division

  36. Situations to Consider Exposure Protection • A large fire that cannot be immediately extinguished. • Employing a nonintervention strategy. • Extremely sensitive structures. (fuel tanks, etc) • Structures in the vicinity showing the effects of exposure to the fire. Colleton County Fire-Rescue Training Division

  37. Factors That Determine the Danger of an Exposure • Amount and intensity of the original fire. • Proximity of the exposure to the fire. • Wind and weather conditions. • Composition of the exterior of the exposure. Colleton County Fire-Rescue Training Division

  38. Water Supply Considerations • Foam operations usually require significant amounts of water. • Have the required water available before beginning foam operations. • Rule of thumb is 1 gallon per min for every 10 sq ft. Colleton County Fire-Rescue Training Division

  39. Water Supply Considerations Questions to ask • What is my water requirements? • What is my water supply available? • Does access to the scene inhibit my ability to deliver the required flow? Colleton County Fire-Rescue Training Division

  40. Summary • Principals and considerations for fighting Class A and Class B fires vary. • There are may myths myths surrounding Class A foam • Class A Foam is an effective tactic for structural fire attack, exposure protection and overhaul. • Techniques of Class B foam application vary with the prescribed application and take in account many considerations . Colleton County Fire-Rescue Training Division

  41. Summary • What are the considerations after Class B foam is applied? • Exposure protection for Class B fire incidents are integral to an effective incident management strategy. • Water supply considerations for Class B Foam operations. Colleton County Fire-Rescue Training Division

  42. Questions??? Colleton County Fire-Rescue Training Division

  43. Acknowledgements • IFSTA Principals of Foam Firefighting 1st Edition, 1996 • Dominic Colletti, Class A Foam-Best Practice for Structural Firefighters, 1998 • Various Web Sources • Task Force Tips • Elkhart Brass Manufacturing • Operations Chief David A Greene Colleton County Fire-Rescue Training Division