TB Analysis. Alessandra Borgia & Marina Artuso VELO Group Meeting, Friday April 3, 2009. Important Data Info. 20k evts First 2 channels of each channel removed ONLY considered: 1 cluster events => 1 cluster per sensor for Reference Tell1 ( ≡ low irradiated sensor)

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' TB Analysis' - finn


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Tb analysis

TB Analysis

Alessandra Borgia & Marina Artuso

VELO Group Meeting,

Friday

April 3, 2009


Important data info
Important Data Info

  • 20k evts

  • First 2 channels of each channel removed

  • ONLY considered:

    • 1 cluster events => 1 cluster per sensor for Reference Tell1 ( ≡ low irradiated sensor)

    • All cluster events for highly irradiated Tell1

  • Beam @ top –Sec 3– Tell1 8 High Irradiation

  • Beam @ bottom –Sec 0– Tell1 5 High Irradiation

  • Test Module –beam @ Sec 0– R Sensor only

Alessandra Borgia, SU Velo Meeting


Position of irradiation spots
Position of irradiation spots

Tell1 8

n-in-p

Tell1 5

n-in-n

Top

  • lars config

  • run over 20000 events

    Voltages:

  • 500V on each sensor

  • 300V on High irradiated and 500V on Low irradiated

Beam

High Irr

Low Irr

Bottom

Alessandra Borgia, SU Velo Meeting


Beam @ Top:

300 V

400 V

500 V

Tell1 8

1 Strip Clusters Only

Beam intensity ~ 200k/spill for 300 V

~ 100k/spill for 400 & 500 V

Alessandra Borgia, SU Velo Meeting


Beam @ Top:

300 V

500 V

400 V

Tell1 8

1 Strip Clusters on 5

2 Strip Clusters on 8

Beam intensity ~ 200k/spill for 300 V

~ 100k/spill for 400 & 500 V

Alessandra Borgia, SU Velo Meeting


Compare between: Test Module & Tell1 5 (Low Irr)

1 Strip Clusters, 1 Cluster per Sensor ADC Distribution

Tell1 8 / Test Module

Tell1 5 / Beam @ Top

Alessandra Borgia, SU Velo Meeting


Compare between: Test Module & Tell1 5 (Low Irr)

1 Cluster per Sensor ADC Distribution

Tell1 8 / Test Module

Tell1 5 / Beam @ Top / 1 Strip Clust on Tell1 5, 2 Strip Clust on Tell1 8

Alessandra Borgia, SU Velo Meeting


Compare between: Test Module & Tell1 8 (Low Irr)

1 Strip Clusters, 1 Cluster per Sensor ADC Distribution

Tell1 8 / Test Module

Tell1 8 / Beam @ Bottom

Alessandra Borgia, SU Velo Meeting


Compare between: Test Module & Tell1 8 (Low Irr)

1 Cluster per Sensor ADC Distribution

Tell1 8 / Test Module

Tell1 8 / Beam @ Top / 1 Strip Clust on Tell1 8, 2 Strip Clust on Tell1 5

Alessandra Borgia, SU Velo Meeting


Test Module Fits

LanGaus Fit

Landau Fit

  • MP = 22.58

  • Landau Width = 1.094

  • MP = 22.47

  • Landau Width = 1.482

Alessandra Borgia, SU Velo Meeting


Beam @ Top:

Tell1 5 / LanGaus Fit

Tell1 8 /LanGaus Fit

  • MP = 22.17

  • Landau Width = 1.013

  • MP = 15.3

  • Landau Width = 0.6033

Alessandra Borgia, SU Velo Meeting


Beam @ Top: Bad fits…how can I fix?

Tell1 5 / Landau +10 flat background

Tell1 8 / Landau +10 flat background

  • 0-60 range fit

  • 12-55 range fit

Alessandra Borgia, SU Velo Meeting


Beam @ Bottom:

Tell1 5 / Landau Fit

Tell1 8 /LanGaus Fit

  • MP = 14.99

  • Landau Width = 1.198

  • MP = 20.98

  • Landau Width = 0.646

Alessandra Borgia, SU Velo Meeting


Beam @ top
Beam @ Top:

100 to 300 um

Tell1 8 / Irr / 500V / ADC Distribution in different ranges

-100 to - 300 um

300 to 500 um

- 100 to +100 um

20k evts in file: RR-beam-top-larscfg-HV500-HV500-20080626-181912.mdf;

Intensity = 100 k/spill; ELOG msg: 206 & 203

Alessandra Borgia, SU Velo Meeting


Beam @ Top:

Tell1 8 / Irr / 500V / ADC Distribution in different ranges

100 to 300 um

-100 to - 300 um

300 to 500 um

- 100 to +100 um

50k evts in file: RR-beam-top-larscfg-HV500-HV500-20080626-181912.mdf;

Intensity = 100 k/spill; ELOG msg: 206 & 203

Alessandra Borgia, SU Velo Meeting


Beam @ bottom
Beam @ Bottom:

100 to 300 um

Tell1 5 / Irr / 500V / ADC Distribution in different ranges

-100 to - 300 um

300 to 500 um

- 100 to +100 um

20k evts in file: RR-beam-larscfg-HV500-HV500-20080625-150229.mdf;

Intensity = 150 k/spill; ELOG msg: 179 & 196

Alessandra Borgia, SU Velo Meeting


Beam @ Bottom:

Tell1 5 / Irr / 500V / ADC Distribution in different ranges

100 to 300 um

-100 to - 300 um

300 to 500 um

- 100 to +100 um

50k evts in file: RR-beam-larscfg-HV500-HV500-20080625-150229.mdf;

Intensity = 150 k/spill; ELOG msg: 179 & 196

Alessandra Borgia, SU Velo Meeting



Beam @ Top:“Fat” = unfocused beam

Tell1 5 / low irr / 1Strip 1Clust

Tell1 8 / high irr / 1Strip 1Clust

Alessandra Borgia, SU Velo Meeting


Beam @ Top:“Fat” = unfocused beam

Tell1 5 / low irr / 1Strip 1Clust

Tell1 8 / high irr / 2Strip 1Clust

Alessandra Borgia, SU Velo Meeting


Beam @ Top:focused vs unfocused

Tell1 5 / low irr / 1strip 1clust / focused

Tell1 5 / low irr / 1strip 1clust / UNfocused

Alessandra Borgia, SU Velo Meeting


Beam @ Top:focused vs unfocused

Tell1 5 / 1 Strip Clust on Tell1 5, 2 Strip Clust on Tell1 8 / focused

Tell1 5 / 1 Strip Clust on Tell1 5, 2 Strip Clust on Tell1 8 / UNfocused

Alessandra Borgia, SU Velo Meeting


Beam @ Top:focused vs unfocused

Tell1 8 / high irr / 1strip 1clust / focused

Tell1 8 / high irr / 1strip 1clust / UNfocused

Alessandra Borgia, SU Velo Meeting


Beam @ Top:focused vs unfocused

Tell1 8 / 1 Strip Clust on Tell1 5, 2Strip Clust on Tell1 5 / focused

Tell1 8 / 1 Strip Clust on Tell1 5, 2Strip Clust on Tell1 5 / focused

Alessandra Borgia, SU Velo Meeting


Data files used
Data files used

  • Test Module:

    • RPHI-beam-lars-cfg-HV100-HV100-20080624-080945.mdf

  • RR Beam @ Top:

    • RR-beam-top-larscfg-HV500-HV500-20080626-181912.mdf

  • RR Beam @ Bottom:

    • RR-beam-larscfg-HV500-HV500-20080625-150229.mdf

  • RR Beam @ Top – Unfocused:

    • RR-fatty-fat-fat-beam-top-HV500-HV500-20080627-160833.mdf

Alessandra Borgia, SU Velo Meeting