Pyrrole-hyaluronic acid conjugate for neural probe, stents, and sensor applications. Jae Y Lee and Christine E Schmidt June 19, 2009. Implantable electrodes. Loss of electrical sensitivity Increase in impedance Highly sensitive electrodes are required Nerve tissue reaction

ferris
Download Presentation

Pyrrole-hyaluronic acid conjugate for neural probe, stents, and sensor applications

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pyrrole-hyaluronic acid conjugate for neural probe, stents, and sensor applications Jae Y Lee and Christine E Schmidt June 19, 2009

  2. Implantable electrodes • Loss of electrical sensitivity • Increase in impedance • Highly sensitive electrodes are required • Nerve tissue reaction • - Acute and chronic responses • - Foreign body reaction • - Glial scar tissue formation Neural electrodes a) GFAP-stained (3 weeks) b) a) J Neural Eng 2007 Williams CJ et al. b) Biomaterials 2003 Cui X et al. . Technology and properties • Electrochemical deposition of HA on conductive materials • - Electrically conductive • - Cytocompatible • - Stable • - Hydrophilic • - Resistant to protein fouling and cell adhesion

  3. Electrochemical coating process Stable HA coating 0 – 1.0 V (vs SCE) Conductive substrate or electrode (e.g., ITO, PPy) HA coating solution

  4. Surface characterization • Immunostaining of HA using bHABP, followed by PE-streptavidin Bare ITO HA caoted ITO Border ITO HA-coated ITO • Water contact angle measurement Bare ITO HA-coated ITO

  5. Electrochemical Impedance Spectroscopy (EIS)  Electrical properties of uncoated and HA-coated ITO are the same

  6. In vitro astrocyte culture Immunostaining three days in culture Long-term culture Bare ITO HA-coated area 10 days 90 days Unmodified area HAase-treated HA-coated ITO • scale bars = 50 µm • GFAP (green), DAPI (blue), HA (red) • Images were taken at the same location for all time points. • Scale bars are 50 µm