Technical Description: High Altitude Analysis

Technical Description: High Altitude Analysis. COOLING ISSUES: Reference Document: ALMA memorandum n°203 and standard engineering thermal calculations;

Download Presentation

Technical Description: High Altitude Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Technical Description: High Altitude Analysis • COOLING ISSUES: • Reference Document: ALMA memorandum n°203 and standard engineering thermal calculations; • Data from suppliers of electrical and electronics equipment: derating of 5% every 1.000 m of altitude increments (derating of 25% at 5.000 m a.s.l.); • a value equal to 35% for the electrical equipments, continuously working at the nominal power, should be considered conservative; • For users such as the Feed Shutter or Stow Pins, no derating can be applied; • In any case, the power derating factor of 35% should be taken as the basis for the electrical dimensioning of the equipment working at the nominal power; • Different deratings can be applied with a dedicated duty-cycle calculation vs. thermal dissipation (when in air); • Exceptions to reduction factor are possible were the cooling of the equipment is made by refrigerating liquids. • ELECTRICAL INSULATION ISSUES: • Reference Document: IEC 60664; • Evaluation of the “pollution degree”; • Over-voltage categories identification; • Analysis on the electrical/electronic apparatuses w.r.t. they working voltages; • Corrective Factors for altitudes above 2000m

  2. The general effect of electrical and environmental factors on creepage distance and clearance: • pollution degree, • overvoltage category, • working voltage, • the previous factors cumulatively, • comparative tracking index (applies to creepage distance only), • altitude (applies to clearance distance only). • For elevations above 2000 m, the required clearance is increased by the following factors: to 3000 m, 1.14; from 3000 to 4000 m, 1.29; and from 4000 to 5000 m, 1.48

More Related