Week #7 Data Acquisition System, Part (A)

Week #7 Data Acquisition System, Part (A). ENG3640 Microcomputer Interfacing. Topics. Data Acquisition Systems Digital-to-Analog Converters Analog-to-Digital Converters MCU12 ADC Signal Conditioning. Resources. Huang, Chapter 12, Sections

elmo
Download Presentation

Week #7 Data Acquisition System, Part (A)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Week #7 Data Acquisition System, Part (A) ENG3640 Microcomputer Interfacing

  2. Topics • Data Acquisition Systems • Digital-to-Analog Converters • Analog-to-Digital Converters • MCU12 ADC • Signal Conditioning ENG3640 Fall 2012

  3. Resources • Huang, Chapter 12, Sections • 12.1 Data Acquisition Systems • 12.2 Basics of A/D Conversion • 12.3 The HCS12 A/D Converter • 12.6 – 12.8 Sensors ENG3640 Fall 2012

  4. Port AD Analog to Digital 1-KB SRAM 4-KB EEPROM 68HC812A4 Block Diagram CPU12 Interrupts Port T Timer Module I/O Ports I/O Ports ENG3640 Fall 2012

  5. Data Acquisition System • The purpose of any data acquisition system is to acquire analog signals and present them to the MCU in a form that can be manipulated. • The main components of any general data acquisition system consists of the following: • Transducers (sensors) • Analog Multiplexer • Signal Conditioning (Amplification, Filtering, ..) • Sample and Hold Circuit • Analog to Digital Converter • Microcomputer System • Digital to Analog Converter • Actuator ENG3640 Fall 2012

  6. Data Acquisition Components • Transducers (sensors) convert variable processes such as pressure, temperature into electrical signals such as voltage or current. • Signal conditioning: • Isolation & buffering: protection from dangerous voltages (i.e. interfacing an MCU to a 110V or 220V) • Amplification: Need full scale signal for conversion (transducers usually provide very small signals millivolts) • Bandwidth limiting: Low pass filter to limit range (noise) • Sample and Hold: used to keep signals constant while converting an analog signal to digital • A/D and D/A are interfaces to the MCU to the outside world • Actuators: interfaces to activate motors, switches, e.t.c ENG3640 Fall 2012

  7. Signal Paths of a DAS Signal Conditioning Humidity Analog Mux Real World Measurand Temp Transducer (sensors) Pressure …… A/D Conv D/A Conv Sample and Hold Circuit MCU Actuator ENG3640 Fall 2012

  8. Signal Conditioning: Op-Amps Inverting Non-inverting • Operational Amplifiers are electronic devices used to amplify signals, filters, signal conditioning, e.t.c. • It consists of three terminals (two inputs, one output) • OP-AMPs require dc power to operate (+VCC, -Vcc) • OPERATION: OP-AMPS are designed to sense the difference between the voltage signals applied to its two input terminals (V2 – V1) , multiply this by a number A , and cause the resulting voltage A (V2 – V1) to appear at output terminal 3. ENG3640 Fall 2012

  9. Operational Amplifiers: Rules for Analysis +12V +12V Inverting Non-inverting -12V -12V Voltage ranges are bounded by supply voltage i.e +/- 12V Input currents are zero because input impedance is large (infinite input impedance for ideal op-amp) Positive feedback or no feedback drives output to saturation (i.e. +12V and -12V) A Virtual short circuit exists between the two input terminals (i.e. whatever voltage is at terminal 2 will automatically appear at terminal 1) due to infinite gain A. ENG3640 Fall 2012

  10. Inverting OPAMP ENG3640 Fall 2012

  11. Analysis of Inverting OPAMP ENG3640 Fall 2012

  12. Inverting Adder According to virtual ground rule, voltage at inverting and non-inverting inputs are 0. According to Ohm’s law: i1 = V1/R1, i2 = V2/R2, … All these currents sum together to produce the current i; that is i = i1 + i2 + i3 (will be forced to flow through Rf) The output voltage V0 = 0 – iRf = -iRf ENG3640 Fall 2012

  13. Binary Weighted DAC The binary weighted DAC is the simplest converter. This DAC creates currents that are proportional to the weight of each code bit. The inverting OP AMP can produce an output voltage which is linear combination of several input voltages. ENG3640 Fall 2012

  14. Binary Weighted DAC • By using input resistors which scale by a factor of 2, a summing Op Amp can produce an output which follows a binary pattern. ENG3640 Fall 2012

  15. Binary Weighted DAC • By using switches on the input resistors, a summing Op Amp can produce an output which is a binary number (representing which switches are closed) times a reference voltage. Conversion Factor ENG3640 Fall 2012

  16. Binary Weighted DAC • CF = - (RF/R0)VB is called the conversion factor or quantum interval. • The quantum Interval is defined as the change in output signal for a unit change of input code, 0000, 0001, 0010 • The largest voltage that can be produced by an n-bit binary DAC is Vmax = (2n-1)CF • NOTE: CF will be set to the maximum allowable value which is limited by the maximum output of the OP-AMP (VOM) • The largest conversion factor is calculated as CFMAX = (VOM)/(2n-1) ENG3640 Fall 2012

  17. Binary Weighted DAC: Example • A 4-bit binary weighted DAC has values of RF = 10K, R0=360K • What is the value of R1, R2, R3 • Calculate (a) the conversion factor when VB = -8V (b) and the maximum output of the system. • Solution: • R0 = 2R1 = 4R2 = 8R3, So R1 = 180K, R2 = 90K, R3 = 45K • CF = (-RF x VB)/R0 = -(10)(-8)/360 = 0.222 • Maximum output of this system emax = (2N-1) x CF = 15 x 0.222 = 3.33V ENG3640 Fall 2012

  18. A-to-D Conversion Samples in the Time Domain • When an analog signal is to be represented by a digital code  the range of analog signal is divided into levels (quantization levels)  Pulse Code Modulation (PCM) • Using level numbers to represent analog signals leads to Inaccuracy  Quantization Error (shaded region) • Sampling theory states that if samples are taken of an analog signal, the original analog signal can be recovered if  fs > 2B ENG3640 Fall 2012

  19. A Simple A/D Converter • Components: (a) Counter (b) D/A (c) Comparator (d) Latch • The counter counts from 0 to 2n-1 • The counter drives the input of the D/A converter • The output of the D/A is compared to the input voltage vin • When the output of the comparator switches logic this means that the generated voltage of D/A passed the input voltage. • The comparator then latches the counter output to the latch. • Problem with Slope A/D?  it takes 2n clock cycles for conversion ENG3640 Fall 2012

  20. Recall: Staircase A/D Converter • Problem with Slope A/D  it takes 2nclock cycles for conversion • Can we do better! ENG3640 Fall 2012

  21. Tracking Converter • Is an improved version of the staircase ADC • If VA increases over previously converted value the counter will count up • If VA decreases over previously converted value the counter will count down • Conversion time is Not Constant ENG3640 Fall 2012

  22. Successive Approximation A/D • Is based on intelligent trial-and-error method • When start signal is asserted the controller instructs the sequencer to • Place a `1’ in MSB position of Register. • All other bits remain at `0’ level • A comparator compares two voltage values on its two inputs. • If guess is low then the next MSB is set to `1’ • If guess is high then that bit is set to `0’ and the next MSB is set to `1’ • Requires N clock periods for N-bit converter. ENG3640 Fall 2012

  23. Successive-Approximation Example • 6-bit A/D with range 0V – 5V • Step Size = 5/26 = 0.078 ENG3640 Fall 2012

  24. Successive-Approximation Example • 4.16 – 4.141 = 0.019 • Error is smaller than ½ LSB Digital output is 110101 ENG3640 Fall 2012

  25. Successive Approximation A/D • A Successive Approximation A/D can give the wrong output if the voltage changes during a conversion • A Track/Hold or Sample/Hold circuit is needed to hold the input voltage constant during conversion. ENG3640 Fall 2012

  26. Sample and Hold Circuit • Circuit  Capacitor & Switch • It works by charging the capacitor to the input voltage, then disconnecting the capacitor from the input voltage during conversion. ENG3640 Fall 2012

  27. Concepts and Terminology • Analog signals have a ratio-metric range • These range from a low value to a high value • 0V to 5V • -2.5V to 12.5V • 4mA to 20mA • Binary Code representation for Analog (0V to 5V) • 0V  $00 • 5V  $FF • 2.5V  $80 (middle of analog range) • If the analog range starts from a nonzero minimum value it is usually represented by an “offset binary code” • e.g. -2.5 V - +12.5V, then -2.5 == $00 ENG3640 Fall 2012

  28. Concepts and Terminology • Definitions :Assume an analog signal ranges from 0V-5V, and number of bits used in A/D converter is 3 • Offset Minimum Analog Value  0V • Span  Max to Min Analog Value  5V-0V = 5V • Step Size, Quantum Interval  Span/2n • Resolution  Refers to the number of bits in ADC and also to smallest analog change corresponding to a change in a bit in the digital number. • Conversion: • Analog Number = (Digital Number x Step Size) + Offset • Digital Number = (Analog Number – Offset)/Step Size • Dynamic Range (DR) = (Range or Span)/Resolution = 2n The dynamic range determines the required word size of an ADC. ENG3640 Fall 2012

  29. Example • A 6-bit DAC has an analog output range of -2.5 to 5.0V. Calculate the analog output when input is 010101 (i.e. decimal 21) • Solution: • Offset = -2.5 • Span = 5 – (-2.5) = 7.5V • Step Size = 7.5V/26 = 10/64 = 0.1172V • Analog Output = (digital number x step size) + offset = (21 x 0.1172) – 2.5V = -0.039V ENG3640 Fall 2012

  30. Example • A temperature sensor has a measurement range of -10 to 140C. The output range is -2.5 to +5mv. It has a resolution of 0.5C. • Determine the # of bits in ADC? • What is the reading of the ADC when the output of the sensor is -1.0 mv? • Solution: • Span = 140 – (-10) = 150 C (or) 5 – (-2.5mv) = 7.5mv • Dynamic Range = 150 C / 0.5C = 300 DR = 300 = 2n  n = log2 (300) = 8.22  9 bits • Step Size = Span /2n = 7.5mv/(29) = 0.01464 • Digital Number = (Analog Number – Offset)/Step Size = (-1.0mv – (-2.5mv))/0.01464 = (102)10 = (001100110)2 ENG3640 Fall 2012

  31. CPU12 ADC Subsystem: Features • The CPU12 has no DAC! • Features of the ADC module include: • Eight multiplexed input channels • ADC based on successive approximation • 8-bit Resolution • Single or continuous conversion • Conversion complete flag with CPU interrupt request. • Selectable ATD clock ENG3640 Fall 2009 ENG3640 Fall 2012 31

  32. CPU12 A/D • The HC12 has a sample/hold amplifier built in. • The Successive Approximation A/D converter has speeds up to several million samples per second. • VRH is the highest voltage the A/D converter can handle • VRL is the lowest voltage the A/D converter can handle ENG3640 Fall 2012

  33. CPU12 A/D Channel 0 Analog Multiplexer The HC12 uses an analog multiplexer to allow eight input pins to connect to the A/D converter ENG3640 Fall 2012

  34. CPU12 A/D: Control and Status Registers ENG3640 Fall 2012

  35. CPU12 A/D: Control Registers • ADPU  1: Powers up the A/D ( if ADPU  0, then AD Port General Purpose). Stabilization Period! • SCAN: Perform one conversion or continuous • MULT: Conversion of sequential channels or single channel ADPU SCAN MULT ENG3640 Fall 2012

  36. CPU12 A/D: Channels ENG3640 Fall 2012

  37. CPU12 A/D: ATDCTL2 • Could either use Polling or Interrupt Driven I/O • If ASCIE  1, then interrupt requests are enabled. • The ASCIF interrupt FLAG is set = 1, when conversion sequence is complete. ASCIE ASCIF ENG3640 Fall 2012

  38. CPU12 A/D: ATDCTL4 Conversion Time = Initial Sample Time + Transfer Time + Final Sample time + Resolution Time SMP1 SMP0 PRS4 PRS3 PRS2 PRS1 PRS0 ENG3640 Fall 2012

  39. CPU12 A/D: ATDCTL5 • The S8CM bit in ATDCTL5 is used to select conversion sequences of either 8 or 4 conversions. • If set to  0, then 4 conversion sequences are selected and remember that the result is stored in ADRH2 and not ADRH6 if CC=1, CB=1, CA =0 (0110) AN6 ADRxH2 S8CM ENG3640 Fall 2012

  40. CPU12 A/D: Status Registers • SCF (Sequence Complete Flag) • In single conversion sequence mode, SCF set at end of conversion • In continuous conversion mode, SCF is set at end of first conversion • CCF0-CCF7 (Conversion Complete Flags) • Each ATD channel has a CCF flag which is set at the end of the conversion on that channel. • CCF flag can be cleared by reading STATUS REGISTER #1 and then reading the result register of that channel. SCF CCF7 CCF0 ENG3640 Fall 2012

  41. CPU12 A/D: LAB ENG3640 Fall 2012

  42. Using the ATD to Measure Signal ; -------------------------------------------------------------------- ; Main Program ;--------------------------------------------------------------------- ORG $7000 ; 16K on board RAM MAIN: BSR INIT ; branch to init ATC BSR CONVERT ; Branch to conversion DONE: BRA DONE ; Branch to Self ;----------------------------------------------------------------------- ; Subroutine INIT ;----------------------------------------------------------------------- INIT: LDAA #$80 ; Power up ATC STAA ATDCTL2 ; ATD Flags clear normally & Disable Interrupt BSR DELAY ; Delay (100 us) LDAA #$00 ; Select continue conversion in BGND Mode STAA ATDCTL3 ; Ignore FREEZE in ATDCTL3 LDAA #$01 ; Select Final sample time = 2 A/D clocks STAA ATDCTL4 ; Prescaler = Div by 4 RTS ENG3640 Fall 2012

  43. Using the ATD to Measure Signal ;----------------------------------------------------------------------- ; Subroutine DELAY 100 us ;----------------------------------------------------------------------- ; Delay required for ATD converter to stabilize (100 usec) DELAY: LDAA #$C8 ; Load Acc with “100 usec delay value” DECA ; Decrement ACC BNE DELAY ; Branch if not equal to Zero RTS ; Return from subroutine ENG3640 Fall 2012

  44. Using the ATD to Measure Signal ; -------------------------------------------------------------------- ; Subroutine Convert ; set-up ATC, make single conversion and store result to a memory location ; Configure and start A/D conversion ; Analog Input Signal: on Port AD6 ; Convert: using single channel, non-continuous ; The result will be located in ADR2H ;--------------------------------------------------------------------- CONVERT LDAA #$06 ; Initialize ATD  SCAN = 0, MULT=0, ; ; S8CM = 0, PAD6, Write clears Flag STAA ATDCTL5 ; 4 Conversions on a Single Conversion ; sequence WTCONV: BRCLR ATDSTATH,#$80,WTCONV; Wait for Sequence Complete Flag LDD ADR2H ; Loads Conversion result (ADR2H) ; into Accumulator RTS ; Return from Subroutine ENG3640 Fall 2012

  45. Summary • Data acquisition systems consists of several components (i) sensors (ii) signal conditioning, (iii) Analog to Digital Converters, (iv) MCU, (v) Digital to Analog converters. • Engineers must justify the usage of each component in the path and consider (i) Cost, (ii) error • Operational Amplifiers are at the heart of Signal conditioning circuits, ADCs, DACs and therefore analysis of these circuits is very important. • Determining the # of bits required by ADC or DAC is important and knowing the sampling frequency is also as important to recover the original signal. • There are several types of ADCs available (next topic) ENG3640 Fall 2012

  46. Extra Slides ENG3640 Fall 2012

  47. Example • Given an analog signal with range -5V to +5V and an 8-bit ADC • Determine: Offset, Span, Step Size, %Resolution • Solution: • Offset = -5V • Span = 5 – (-5) = 10V • Step Size = 10V/28 = 10/256 = 39.1mv • % Resolution = 0.391% ENG3640 Fall 2012