Case study uv disinfection interference at big rapids wwtp
Download
1 / 24

Case Study UV Disinfection Interference at Big Rapids WWTP - PowerPoint PPT Presentation


  • 205 Views
  • Uploaded on

Case Study UV Disinfection Interference at Big Rapids WWTP. 83 rd Annual Conference Michigan Water Environment Association June 23, 2008. Jack D. Fraser City of Big Rapids. Jerald O. Thaler, P.E. Fishbeck, Thompson, Carr & Huber, Inc. AGENDA. Historical Background Source of Problem

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Case Study UV Disinfection Interference at Big Rapids WWTP' - elita


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Case study uv disinfection interference at big rapids wwtp l.jpg

Case StudyUV Disinfection Interferenceat Big Rapids WWTP

83rd Annual Conference

Michigan Water Environment Association

June 23, 2008

Jack D. Fraser City of Big Rapids

Jerald O. Thaler, P.E.

Fishbeck, Thompson, Carr & Huber, Inc.


Agenda l.jpg

AGENDA

  • Historical Background

  • Source of Problem

  • Control Mechanism

  • Summary and Questions



Slide4 l.jpg

2002

  • Nestle Waters North America opened major pumping and bottling facility in Stanwood, MI.

  • Produced Ice Mountain® and Pure Life® (“Splash”) fruit-flavored bottled waters.

  • Process wastes trucked offsite for disposal.


Slide5 l.jpg

2003-2005

  • Recurring fecal coliform violations led City to replace aging UV disinfection system.

  • Nestle Stanwood approached City to accept trucked process wastes at WWTP.

    • Standard policy not to accept trucked wastes.

    • Significant revenue potential (up to $25,000/month).

    • Characterization study indicated “clean” wastes.

  • City decided to accept wastes; construction of UV system began approximately the same time.


Slide6 l.jpg

2006

  • Fecal coliform violations continued, even after start-up of new UV system.

  • MDEQ initiated enforcement response action.

  • Aggressive investigations into cause:

    • Revisited basis of design for new system.

    • Collected daily transmittance data from WWTP effluent.

    • Collected color/odor observations and transmittance data from each Nestle Stanwood truckload.

    • Nestle Stanwood and Michael Goergen/Merit Laboratories evaluated chemicals potentially in waste.



Slide8 l.jpg

Suspected Culprit

  • Data suggested problem was potassium sorbate.

    • Widely used preservative in the food industry.

    • Additive in Splash fruit-flavored water.

    • Salt of sorbic acid (C5H7COOH), a natural organic compound with anti-microbial properties.


Potassium sorbate l.jpg
Potassium Sorbate

  • Absorbs UV, unlike turbidity that blocks UV.

    • Peak absorption at 255 nanometers (nm).

    • Peak output of standard UV disinfection lamp is 254 nm.

Germicidal Curve:



Slide11 l.jpg

Local Limit Options

  • Maximum Concentration

    • No data to correlate discharge concentration to interference

    • Testing issues (costs and turnaround time)

  • Minimum Transmittance

    • Much data to correlate discharge transmittance to interference

    • Straightforward testing

    • No experience or USEPA/MDEQ guidance on developing limit


General methodology for developing local limits l.jpg
General Methodologyfor Developing Local Limits

  • Maximum allowable headworks loading (MAHL).

  • Domestic/background loading (LBKGD).

  • Maximum allowable industrial loading (MAIL):

MAIL = MAHL*(1-Safety Factor) - LBKGD

  • Allocation of MAIL among industrial users.


Transmittance t l.jpg
Transmittance (T)

  • Definition:

    where: I = intensity of UV light leaving sample

    Io = intensity of UV light entering sample

  • Characteristics:

    • Not proportional to concentration

    • Not additive

    • Poorly adaptable to mathematical manipulation


Absorbance a l.jpg
Absorbance (A)

  • Related to T via Beer-Lambert Law:

    or

  • Characteristics:

    • Proportional to concentration

    • Additive

    • Highly adaptable to mathematical manipulation


Calculation procedure l.jpg
Calculation Procedure

  • Assume effluent absorbance (AEFF) consists of three additive components:

    • Correction for total suspended solids present

    • Domestic/background residual

    • Industrial user pass-through


Calculation procedure continued l.jpg
Calculation Procedure (continued)

  • Assume remain below maximum allowable effluent absorbance:

  • Use site-specific data to calibrate parameters.

  • Solve for AIU, then transpose to TIU:


Tss correction coefficient a tss l.jpg
TSS CorrectionCoefficient (ΔATSS)


Domestic background residual a bkgd l.jpg
Domestic/BackgroundResidual (ABKGD)


Removal of industrial user absorbance r iu l.jpg
Removal of Industrial User Absorbance (RIU)


Maximum allowable effluent absorbance a max l.jpg
Maximum AllowableEffluent Absorbance (AMAX)


Results l.jpg
Results

  • Solving for ASIU and transposing to TSIU:


Permit conditions l.jpg
Permit Conditions

  • Permit negotiations led to following:

    • No acceptance if TSSEFF>15 mg/L

    • Trucked waste volume up to 120,000 gal/day

  • Minimum transmittance limit set at 70%...


Summary l.jpg
Summary

  • Apparent “clean” waste caused interference.

  • If using UV disinfection, be alert out for food processors using potassium sorbate.

  • For local limit in T, best to work mathematics in A and then transpose.

  • Other lessons learned:

    • Do not always know what you will get, particularly with trucked waste.

    • If get into problem, maximize expertise by using all available resources.

    • Permit the discharger, not the transporter.