Maryland Transportation Authority Police Training Facility. Schematic Design Presentation December 13, 2007 Leah Clark. Overview. Location: Hawkins Point, Baltimore, Maryland Size: • 42,100 square feet • 2 stories above grade Project Team:

Download Presentation

Maryland Transportation Authority Police Training Facility

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Maryland transportation authority police training facility

Maryland Transportation Authority Police Training Facility

Schematic Design Presentation

December 13, 2007

Leah Clark


Overview

Overview

Location: Hawkins Point, Baltimore, Maryland

Size:

• 42,100 square feet

• 2 stories above grade

Project Team:

• Owner: Maryland Transportation Authority • Mechanical and Electrical: Johnson, Mirmiran, & Thompson

• Architectural: Rubeling & Associates• Civil and Structural: Carroll Engineering, Inc.• Construction Manager: To be determined by competitive bid among prequalified biddersContractor: To be determined (by bid among prequalified contractors)


First floor

First Floor

Front Façade

Physical Training Gym

Classroom ‘A’

Firing Range Area


Second floor

Second Floor


Sections

Sections

Classroom ‘A’

Firing Range Area

Front Façade

Physical Training Gymnasium


Sections1

Sections

Classroom ‘A’

Firing Range Area

Front Façade

Physical Training Gymnasium


Classroom a

Classroom ‘A’

Design Criteria

Light Distribution of Task Plane

Uniformity on task plane

Peripheral Emphasis

Control and Flexibility

Variety of tasks

Multiple switching options

Illuminance Levels (to perform task)


Classroom a1

Classroom ‘A’

Whiteboard

Lighting

Under-cabinet

Lighting

Zone 1

Suspended Direct-Indirect

Lighting

Whiteboard

Zone 2

Zone 3

Zone 4

Zone 5

Projection Screen

TV


Classroom a2

Classroom ‘A’


Range area

Range Area

Design Criteria

Control and Flexibility

Pseudo-realistic training environments

Multiple lighting systems

Control system with preset lighting scenes

Illuminance Levels

Vertical face of the targets

Interior Conditions – 50 fc

Exterior Conditions – 10 fc

Horizontal illuminance in the shooting lines

Interior Conditions – 20 fc

Exterior Conditions – 1 fc

Direct Glare

Lower cutoff angles for fixtures


Range area1

Range Area

Dimmable Recessed Compact Fluorescent

Lighting

High Pressure Sodium Fixtures to simulate exterior night lighting scene

Red LED Lighting to signal when firing lane is in use


Range area2

Range Area

Dimmable Recessed Compact Fluorescent

Lighting

Linear Fluorescent Lighting to simulate normal interior conditions

Red LED Lighting to signal when firing lane is in use


Range area3

Range Area

Shooting Targets

Floor Recessed Fixtures illuminate vertical face of targets


Physical training gymnasium

Physical Training Gymnasium

Design Criteria

Control and Flexibility

Allow fixtures to be

Multiple lighting systems

Control system

Illuminance Levels

Highlight Exposed Structure

Uplight ceiling joists


Physical training gymnasium1

Physical Training Gymnasium


Physical training gymnasium2

Physical Training Gymnasium


Front facade

Front Facade

Design Criteria

Sense of Direction

Higher light levels at entrance

Points of interest

 Precast logos

Light Pollution / Trespass

Modeling of Faces and Objects

Safety and security

Security cameras

Light Distribution on Surfaces

Hierarchy of light


Front facade1

Front Facade

Building Identification

MdTA Police Logo

MdTA Logo

Standing Seam Metal Awning

Main Entrance


Front facade2

Front Facade


Thank you