Gs2060 tl260gs product technical training
This presentation is the property of its rightful owner.
Sponsored Links
1 / 42

GS2060/TL260GS Product Technical Training PowerPoint PPT Presentation


  • 111 Views
  • Uploaded on
  • Presentation posted in: General

GS2060/TL260GS Product Technical Training. GS2060/TL260GS – Product Overview. GS2060. GS2060 GSM/GPRS Wireless Alarm Communicator. Overview: The GS2065 provides primary or backup GSM/GPRS communication for Power Series PC1864/1832/1616 control panels. Specifications:

Download Presentation

GS2060/TL260GS Product Technical Training

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Gs2060 tl260gs product technical training

GS2060/TL260GS Product Technical Training

2-Way Wireless Security Suite


Gs2060 tl260gs product overview

GS2060/TL260GS– Product Overview

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

GS2060

GS2060 GSM/GPRS Wireless Alarm Communicator

Overview:

The GS2065 provides primary or backup GSM/GPRS communication for Power Series PC1864/1832/1616 control panels

  • Specifications:

    • Dimensions : 3.937"x5.875"x0.625"

    • (100mmx150mmx15mm)

    • Weight : 310 g

    • Antenna Gain : 2db

    • Input Voltage : 11.1 to 12.6 V (from the Panel Bell output)

    • Current Draw : 65 mA at 12V (400 mA

    • during the GSM transmission)

    • Operating Environment : 5 º C to 40º C

  • (40º F to 104º F)

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

GS2060

GS2060 GSM/GPRS Wireless Alarm Communicator

  • Features:

    • Back up and primary GSM/GPRS alarm communication

    • Panel remote uploading/downloading support via GSM/GPRS

    • Individual Periodic Test Transmission via GSM/GPRS

    • Supervision heartbeats via GSM/GPRS

    • 128-bit AES encryption over GSM/GPRS

    • Full event reporting

    • SIA format

    • PC-Link connection

    • SIM card included

    • Signal strength and trouble display

    • Activating and initializing through Connect 24

    • Quad-Band: 850 MHz, 1900 MHz, 900 MHz

    • and 1800 MHz

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

GS2060

Compatible Control Panel & Cabinet

Control panel: Power Series PC1864/1832/1616 version 4.1 and higher

Cabinet: PC5003C and PC4050C

Compatible Receivers:

Sur-Gard System I Receiver: version 1.10 and higher

Sur-Gard System II Receiver: version 2.00 and higher

Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver)

Product Model and Accessories:

GS2060GS-USA: For US market with AT&T SIM card

GS2060GS-CDN: For Canada market with Roger SIM card

GS-15ANTQ: Antenna Extension Kits with 15 feet cable

GS-25ANTQ: Antenna Extension Kits with 25 feet cable

GS-50ANTQ: Antenna Extension Kits with 50 feet cable

GS2060 GSM/GPRS Wireless Alarm Communicator

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

TL260GS

TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator

Overview:

The TL260GS is an Internet and GSM/GPRS Dual-Path alarm communication for Power Series PC1864/1832/1616 control panels

  • Specifications:

    • Dimensions : 3.937"x5.875"x0.625"

    • (100mmx150mmx18mm)

    • Weight : 320 g

    • Antenna Gain : 2db

    • Input Voltage : 11.1 to 12.6 V (from the Panel Bell output)

    • Current Draw : 100 mA at 12V (400 mA

    • during the GSM transmission)

    • Operating Environment : 5 º C to 40º C

  • (40º F to 104º F)

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

TL260GS

TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator

  • Features:

    • Fully redundant Internet and GSM/GPRS dual-path alarm communication

    • Integrated call routing

    • Panel remote uploading/downloading support via GSM/GPRS and Internet

    • Individual Periodic Test Transmission via GSM/GPRS and Internet

    • Supervision heartbeats via GSM/GPRS and Internet

    • 128-bit AES encryption via GSM/GPRS and Internet

    • Full event reporting

    • SIA format

    • PC-Link connection

    • SIM card included

    • Signal strength and trouble display

    • Activating and initializing through Connect 24

    • Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

TL260GS

Compatible Control Panel:

Control panel: Power Series PC1864/1832/1616 version 4.1 and higher

Cabinet: PC5003C and PC4050C

Compatible Receivers:

Sur-Gard System I Receiver: version 1.10 and higher

Sur-Gard System II Receiver: version 2.00 and higher

Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver)

Product Model and Accessories:

TL260GS-USA: For US market with AT&T SIM card

TL260GS-CDN: For Canada market with Roger SIM card

GS-15ANTQ: Antenna Extension Kits with 15 feet cable

GS-25ANTQ: Antenna Extension Kits with 25 feet cable

GS-50ANTQ: Antenna Extension Kits with 50 feet cable

TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

UL Approval List

GS2060 GSM/GPRS Wireless Alarm Communicator

TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator

  • UL Commercial Burglary

  • Listed as a primary communication channel (heartbeats must be enabled)

  • Listed as a back-up in conjunction with the POTS (daily test transmission)

  • Used as Dual Signaling Line Communication System (redundancy must be enabled)

  • Used as Standard Line Security and Encrypted Line Security System (heartbeats

  • and encryption must be enabled)

  • UL Residential Burglary and Fire

  • Listed as a primary communication channel (monthly test transmission)

  • Listed as a back-up in conjunction with the DACT (monthly test transmission)

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

ULC Approval List

GS2060 GSM/GPRS Wireless Alarm Communicator

TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator

  • ULC Commercial Burglary and Fire

  • Listed as a passive communication module with Security Level P1, P2 and P3 (redundancy must be enabled)

  • Listed as a active communication module with Security Level A1-A4 (heartbeats and encryption must be enabled)

  • ULC Residential Burglary and Fire

  • Listed as a primary communication channel (daily test transmission)

  • Listed as a back-up in conjunction with the DACT (daily test transmission)

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

UL/ULC Listed Installation – Commercial

Supervisory/Test Transmission Requirements

NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations.

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

UL/ULC Listed Installation – Residential

Supervisory/Test Transmission – Requirements

NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations.

2-Way Wireless Security Suite


Gs2060 tl260gs installation and programming

GS2060/TL260GS– Installation and programming

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GS Installation

  • BEFORE YOU BEGIN

  • Have the following ready before installation:

    • PC1864/1832/1616 Control panel with backup battery

    • Battery connection harness

    • PK5500 keypad with battery

    • Screwdriver

  • Prior to installing a GS2060 and TL260GS, contact your monitoring station to determine if it is a master reseller or visit www.connect24.com and become an authorized dealer. In both instances, you will acquire a Profile Number, Installer ID Number and an Installer Password.

  • Please NOTE:

  • You need to activate the SIM card and initialize the communicator (step 1) 24 HOURS BEFORE INSTALLATION.

  • All options of the communicator only could be programmed through Connect 24

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GS Installation

Summary of Installation Steps

Step 1 – Initialize an account via Connect 24 Website (www.connect24.com)

Step 2 – Install and wire the communicator to the control panel (on-site)

Step 3 – Load the programming and test for best signal strength location

Step 4 – Program communication options on the control panel via keypad

Step 5 – Test communication

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 1 – Initialize an account via Connect 24 Website (www.connect24.com)

  • Login to Connect 24 website by using Installer ID and Password to initialize an account

    • Select Profile Number

    • Select Product Model

    • Enter SIM card number

    • Enter DNIS number (if necessary)

    • Enter Account Code

    • Select GPRS Periodic Test Transmission Interval (if necessary)

    • Select Supervisory Type (if necessary)

    • Enable DHCP (if necessary)

    • Enter IP Address (TL260GS only when the installation is static IP)

    • Enter Subnet Mask Address (TL260GS only when the installation is static IP)

    • Enter Gateway Address (TL260GS only when the installation is static IP)

    • Select Ethernet Periodic Test Transmission Interval (if necessary)

    • Select Rate Plan

    • Confirm information and submit activation application

    • NOTE: You still can remotely change these options later via Connect 24 website.

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GS Installation

Step 1 – 1

Select Profile Number

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

Step 1 – 2

Select Module Number

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

Step 1 – 3

Enter SIM Number

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 1 – 4

  • Enter DNIS number

  • Enter Account Code

  • Select Supervisory Type

  • Enable DHCP (if necessary)

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 1 – 5

  • Enter IP Address (TL260GS only)

  • Enter Subnet Mask Address (TL260GS only)

  • Enter Gateway Address (TL260GS only)

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 1 – 6

  • Select Plan Rate

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 2 – 1 Install and wire the communicator to the control panel (on-site)

    • Assemble the communicator with mounting bracket

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 2 – 2 Install and wire the communicator to the control panel (on-site)

    • Insert the communicator into the cabinet and assemble the antenna

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 2 – 3 Install and wire the communicator to the control panel (on-site)

    • Wire the communicator to control panel

  • NOTE: See details in product manual for PC1864/1832/1616 control panel

  • PCLINK Cable Connector

  • Control panel: Red wire is on the right and black is on the left

  • Communicator: Must be reversed (Black wire is on the right and red wire is on the left)

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GS Installation

Step 3 – Load the programming and test for best signal strength location

Ensure the SIM card is inserted

Power up the control panel

The communicator will be programmed by loading the pre-programmed configuration from Connect 24 automatically

Check Green LEDs. You must achieve full or medium signal strength. See details in product manual.

If signal strength is poor, must relocate the control panel or use an external extension antenna kits

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

GS2060/TL260GSInstallation

Installation

  • Step 4 – Program communication options on the control panel via keypad

    • GS2060/TL260GS with PC1864/1832/1616 control panel

      • o Sections [301], [302], [303]: Program Communication Path

        • • DCAA - Internal (Ethernet 1, Ethernet 2, GPRS 1,

        • GPRS 2)

    • o Section [350] : Program Communication Format (Communicator)

      • • (If Option [301] (above) is set to DCAA, Option [350] must be

      • set to SIA, sub-option 5)

    • o Sections [351] to [376] : Program Call Direction

    • o Section [382] : Enable T-LINK Interface (Option [5])

    • o Section [167] : Enable Communication Wait For ACK (Set to 60 seconds)

    • o Section [401] : Enable DLS Session Through GPRS or Ethernet (Option [1])

2-Way Wireless Security Suite


Gs2060 tl260gs product technical training

Installation

GS2060/TL260GSInstallation

  • Step 5 – Test communication

    • 1. Disconnect incoming phone line from TIP and RING on the control panel

    • 2. Verify that LED 2 is on, this indicate that the unit is active

    • 3. Create an alarm transmission

    • 4. Verify alarm transmission by calling monitoring station

    • 5. Re-connect the phone line, if necessary

  • For back-up communication applications, perform steps 1 to 5

  • For primary communication applications, perform steps 3 and 4 only

  • 2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    LED Display

    Installation

    • Trouble Status LED (Yellow – first one from the left)

    • Please see details about the trouble shooting on page 17 in product manual

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    LED Display

    Installation

    • Network Connection Status LED (Red – second one from the left)

    • LED OFF

      • No network connection issue present

    • LED ON

      • Physical Ethernet cable is not connected

      • DHCP configuration fails

      • Fails to get an IP address from the GPRS network

      • GPRS connections has been reset

    • LED blinks quickly once

      • Ethernet transmitting

    • LDE blinks quickly twice

      • Ethernet receiving

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    LED Display

    Installation

    • Signal Strength LED 2 (Green – third one from the left)

    • Signal Strength LED 1 (Green – fourth one from the left)

    • Green LED 2 blinks quickly once

      • GPRS transmitting

    • Green LED 2 blinks quickly twice

      • GPRS receiving

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Keypad Trouble Display

    Installation

    • Trouble Condition

      • General System Trouble

    • Panel Event Buffer Description

      • T-Link Network Fault/Restore includes

        • SIM Lock Trouble

        • GSM Trouble

        • Ethernet Trouble

        • Connect 24 Configuration Trouble

      • T-Link Receiver Trouble/Restore includes

        • Receiver Not Available Trouble

        • Receiver Supervison Trouble

        • FTC Trouble

      • T-Link Comm. Fault/Restore includes

        • Panel Absent Trouble

    2-Way Wireless Security Suite


    Gs2060 tl260gs applications

    GS2060/TL260GS– Applications

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    GS/IP Call Routing (Internal)

    • Communicator Controlled Call Routing

      • – Backup (dual-path)

    • – Redundant (dual-path)

    • Required Programming

      • Panel Sections [301], [302] and [305]

        • • Any of them could be programmed as DCAA

        • DCAA (default): Ethernet 1 → Ethernet 2 → GRPS 1 → GPRS 2

  • Communicator Sections [005]

    • Option [4] - Primary and backup path

    • [ON]: GPRS path primary, Ethernet path backup

    • [OFF]: Ethernet path primary, GPRS path backup

    • Option [5] - Redundant between GPRS path and Ethernet path

    • [OFF]: Disable redundancy

  • [ON]: Enable redundancy

  • NOTE: “Primary and Backup Path” and “Redundant Communication” options need to be configured during the initialization of the account via Connect 24.

  • 2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    GS/IP Call Routing (Internal)

    Backup Mode 1: Ethernet Primary, 4 Receivers

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    GS/IP Call Routing (Internal)

    Backup Mode 2: Ethernet Primary, 2 Receivers

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    GS/IP Call Routing (Internal)

    Backup Mode 3: GPRS Primary, 4 Receivers

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    GS/IP Call Routing (Internal)

    Backup Mode 4: GPRS Primary, 2 Receivers

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    GS/IP Call Routing (Internal)

    Redundant Mode: 4 Receivers

    – (Redundancy between GSM/GPRS path and Ethernet/Internet path)

    NOTE: The application requires 4 different SG receivers or SG-DLR3 IP line cards

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    Other Applications

    • Periodic Test transmission

      • Individual periodic test via GPRS and Ethernet

      • Daily, Weekly and Monthly Interval

      • Configured during the initialization of the account via Connect 24

    • Encryption

      • 128 Bit AES Encryption

      • Turned on by central monitoring station Sur-Gard receiver

      • Encrypted communications enabled after next event sent to the receiver

      • NOTE: Enabling this feature will require more data usage.

    • Read-only Options from Keypad

      • Read all the options of the communicator from LCD keypad

      • Control panel option [851]

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    Other Applications

    • Power Save Mode

      • Extend the battery duration when an AC power loss on control panel

      • Ethernet functionality turned off until a new event need to be transmitted

      • Network Connections LED: OFF

      • Incoming DLS connection will not be possible

    • Hardware Default

      • Reset the programming options to the factory setting (default values)

      • NOTE: Please see details in product manual

    • Software Update

      • Update the firmware through DLS IV locally via PCLINK

      • Update the firmware through DLS IV remotely via Ethernet/Internet (TL260GS only)

    2-Way Wireless Security Suite


    Gs2060 tl260gs product technical training

    Applications

    SIA Report Code

    Event SIA Data CodeSIA Address Field

    Panel Absent Trouble ET001

    Panel Absent Trouble RestoreER001

    Radio Activation RestoreRS001

    Ethernet 1 Test Transmission RP001

    GPRS 1 Test Transmission RP003

    GPRS 2 Test TransmissionRP004

    FTC Restore YK001

    Example: Nri0 ET001

    N= New Event

    ri0=Partition/Area identifier

    ET= Panel Absent Restore

    001=Zone 001

    NOTE: GPRS 2 Test Transmission will only be sent when two different APNs are programmed.

    2-Way Wireless Security Suite


  • Login