An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SPETTROSCOPIA LASER

  2. SPETTROSCOPIA DI ASSORBIMENTO • Assorbimento diretto con laser modulabili laser a diodo laser a coloranti Ti-zaffiro (675-1100 nm) • Sorgenti laser a frequenza fissa Laser Stark Laser Zeeman • Tecniche di assorbimento specializzate

  3. SORGENTI LASER MODULABILI LASER A DIODO ’ - ” R(J”)

  4. SF6 LASER A DIODO SORGENTE CONVENZIONALE

  5. Spettroscopia in cavità ring-down

  6. SORGENTI A FREQUENZA FISSA LASER STARK : molecole polari LASER ZEEMAN (di RISONANZA MAGNETICA) : radicali

  7. LASER STARK FNO transizione 101 vibrazionale 1 stiramento N-F rotore quasi simmetrico ∆J = -1 ∆K = 0 J’’ = 8 K’’ = 7 ∆M = ± 1 polarizzazione perpendicolare Perché le linee hanno questa forma ?

  8. La forma delle linee dipende dal fatto che per aumentare la sensibilità si opera modulando il campo elettrico con rivelazione sensibile alla fase. A segnale crescente un aumento di V produce un aumento del segnale e viceversa: modulazione e segnale sono in fase. A segnale decrescente modulazione e segnale sono fuori fase.

  9. Capacità di misurare frequenze di transizione con la precisione di parti per milione (essenzialmente estendendo i risultati tipici della spettroscopia a microonde nella regione del lontano IR). • Capacità di osservare linee spettrali troppo deboli da essere rivelate con altre tecniche. • Capacità di misurare linee con alta risoluzione spettrale. • Capacità di osservare transizioni usando alcune differenti emissioni laser IR e lontano IR. • Selettività – poiché LMR è limitato alle molecole a guscio aperto, molecole specie a guscio chiuso, che possono essere presenti in concentrazione maggiore, non sono rivelate.

  10. TECNICHE DI ASSORBIMENTO SPECIALIZZATE • Fluorescenza indotta dal laser (LIF) • Ionizzazione multifotonica amplificata dalla risonanza (REMPI) • Spettroscopia optoacustica o fotoacustica (incremento locale di T  onda di pressione) • Effetto lente termico (gradiente termico  variazione dell’indice di rifrazione)

  11. LIF Fluorescenza indotta dal laser Segnale quantitativo: ILIF = ILaser N1 B12Φ Sensibilità: la popolazione dello stato fondamentale fluttua all’inizio la popolazione dello stato che fluoresce è 0 Selettività: risonanza non solo sull’assorbimento, ma anche sulla fluorescenza Problema:Φ 1

  12. REMPI Resonance Enhanced MultiPhoton Ionization Selettività: risonanza Spettroscopia di massa per rivelare lo ione Spettroscopia fotoelettronica per rivelare l’elettrone

  13. M+ M* M 1+1’ REMPI 2+1 REMPI 1+1 REMPI

  14. OTTICA NON LINEARE  = 0 + E + E2 + E3 +…  polarizzabilità  prima iperpolarizzabilità  seconda iperpolarizzabilità P = (1) E + (2) E2 + (3) E3 + … = PL + PNL (1) suscettività al primo ordine (2) suscettività al secondo ordine

  15. DIAGRAMMI DI FEYNMAN ASSORBIMENTO ED EMISSIONE DI 1 FOTONE DIFFUSIONE ELASTICA (RAYLEIGH) DIFFUSIONE ANELASTICA (RAMAN)

  16. ASSORBIMENTO DI 2 FOTONI RADDOPPIO DELLA FREQUENZA

  17. 532 nm 1064 nm 1064 nm RADDOPPIO DELLA FREQUENZA O GENERAZIONE DELLA SECONDA ARMONICA EFFICIENZA 10-12 - 10-5

  18. 532 nm 1064 nm 1064 nm • LiNbO3 Niobato di Litio • KTP = KTiOPO4 Fosfato di potassio titanile • LBO = LiB3O5 Triborato di litio • BBO = b BaB2O4 beta borato di Bario

  19. Dipolo indotto in un campo elettrico Risultato Radiazione intensa in un materiale ottico nonlineare porta ad un raddoppio della frequenza. 1064 nm  532 nm

  20. Tenendo conto della simmetria tra gli ultimi 2 indici ci si riduce da 27 a 18 elementi In presenza di un centro di inversione b = 0

  21. Leggi di conservazione per i fotoni in ottica non lineare L’Energia deve essere conservata: Il Momento deve essere conservato: k = ω/v = ωn/c Sfortunatamente, può non corrispondere ad un’onda a frequenza 0 Il soddisfare queste due relazioni simultaneamente è detto "phase-matching."

  22. SPETTROSCOPIE RAMAN • COORSconventional old-fashioned Raman spectroscopy • Raman risonante • iper Raman20 i • Raman stimolato0  nI • SRG SRLStimulated Raman gain (loss) • Raman inverso • CARS CSRSCoherent anti-Stokes Raman spectroscopy s = 21 - 2 • HORSES HORAS Higher order Stokes effect scattering

  23. 1 LASER RAMAN

  24. RAMAN RISONANTE

  25. RAYLEIGH • RAMAN • RAMAN PRE-RISONANTE • RAMAN RISONANTE • FLUORESCENZA

  26. COMPLESSO PROTEICO CONTENENTE CLOROFILLA a + β CAROTENE RAMAN 407 nm RAMAN RISONANTE 488 nm

  27. DIFFUSIONE RAMAN RISONANTE E FLUORESCENZA 514.5 nm 752 nm Fluorescenza

  28. VANTAGGI • Intensità fino a 104 > Raman ordinario • Intensità elevata anche a concentrazioni basse • Spettro Raman semplificato • Selezione di una molecola entro il campione SVANTAGGI • Necessità di un laser modulabile • Fluorescenza

  29. Surface enhanced Ramanscattering (SERS) • Tecnica in cui la diffusione Raman viene amplificata quando le molecole sono assorbite su superfici metalliche rugose. • Il fattore di amplificazione può essere 1014-1015, permettendo la rivelazione anche di singole molecole. • Regole di selezione diverse in seguito al cambiamento di simmetria causato dall’assorbimento Raman SERS

  30. IPER - RAMAN RAMAN 0  i IPER-RAMAN 2 0  i

  31. Stato Virtuale hv' hv' hv hv hv hv Stato fondamentale IR (1-fotone) Raman (2 fotoni) Iper-Raman (3 fotoni) β: Iperpolarizzabilità μ: Momento di dipolo α: Polarizzabilità

  32. Regole di selezione: Tutti i modi IR attivi sono anche iper-Raman attivi. Alcuni modi silenti sia in IR che in Raman sono iper-Raman attivi. IR x, y, z Raman xx, xy, …, zz Iper Raman xxx, xxy, …, zzz iper Raman = IR  Raman

  33. Benzene: spettro vibrazionale completo

  34. C2H6 IPER - RAMAN IPER-RAYLEIGH assente

  35. Iper - Raman VANTAGGI Osservazione di transizioni silenti in IR e RAMAN Determinazione di  SVANTAGGI Segnale molto debole

  36. RAMAN STIMOLATO • Si osserva al di sopra di una data intensità del fascio incidente e nella direzione del fascio • Ha circa la stessa intensità del fascio incidente • Si osservano frequenze 0  n i

  37. Raman stimolato : STOKES 0 - n i v = 1 v = 0

  38. Raman stimolato : ANTISTOKES 0 + n i Geometria e conservazione della fase

  39. CONSERVAZIONE DELLA FASE

  40. Raman stimolato • Generazione di radiazione laser a frequenze minori e maggiori • Intensità elevata • Determinazione della vita media di stati vibrazionalmente eccitati PROBLEMA : si possono studiare solo le transizioni Raman più intense

  41. 2 LASER RAMAN INVERSO RAMAN RAMAN INVERSO

  42. Campione illuminato simultaneamente da 2 fasci coincidenti di una sorgente continua e di un impulso gigante 0 energia è assorbita dal continuo a 0±vib ed energia è emessa a 0

  43. SPETTROSCOPIA DI ASSORBIMENTO RAMAN (perdita o guadagno) Se il fascio pompa è abbastanza intenso, un fascio coerente e diretto lungo il fascio pompa è emesso dal campione quando hs = hl - hv

  44. Questa tecnica si basa sull’aumento risonante dell’accoppiamento del campo della pompa lcon il campo della sonda s quando la differenza delle frequenze dei due campi si avvicina ad una transizione del materiale l - i Questo accoppiamento causa un guadagno del fascio sonda o una perdita del fascio pompa Questa tecnica si basa sull’aumento risonante dell’accoppiamento del campo della pompa lcon il campo della sonda s quando la differenza delle frequenze dei due campi si avvicina ad una transizione del materiale l - i Questo accoppiamento causa un guadagno del fascio sonda o una perdita del fascio pompa

  45. CARS Coherent AntiStokes Raman Scattering

  46. Lo stato della materia è invariato nel processo, quindi non c'è trasferimento di energia e momento tra radiazione e materia. 3 = 2 1- 2 k3 = 2 k1- k2 Il fascio è quindi monocromatico e direzionale.

  47. La spettroscopia CARS usa la suscettività al terzo ordine (3)ed è una delle spettroscopie in cui si ha mescolamento di 4 onde. • L’eccitazione è data da 2 laser di frequenza 1 e 2 che coincidono spazialmente e temporalmente nel campione e producono un fascio coerente, altamente collimato di frequenza 3 = 2 1- 2 • Sperimentalmente: 1 costante, 2 varia • Quando 1- 2 = vib si osserva un fascio coerente e collimato alla frequenza 3 = 1 + vib • La radiazione Raman emerge come un fascio laser invece di essere diffusa in 3 dimensioni  aumenta la sensibilità rispetto al Raman normale