GPHL Respirator Training. LaTonya Clay, Ph.D. Training Coordinator. Objectives. Define respirator Discuss National Institute for Occupational Safety and Health (NIOSH) requirements Describe N95 and other respirator types Review respirator procedures Seal Check Donning/Doffing

druce
Download Presentation

GPHL Respirator Training

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GPHL Respirator Training LaTonya Clay, Ph.D. Training Coordinator

  2. Objectives • Define respirator • Discuss National Institute for Occupational Safety and Health (NIOSH) requirements • Describe N95 and other respirator types • Review respirator procedures • Seal Check • Donning/Doffing • Describe storage requirements • Discuss Medical Clearance and Fit Testing requirements

  3. Respirators • Personal protective device worn on the face that covers at least the nose and mouth • Reduces the risk of inhaling hazardous airborne particles, including dust and infectious agents, gases, or vapors • Considered the last line of defense in the occupational hierarchy of controls • Recommended when engineering controls are not feasible or sufficient to control the hazard • Protect the user either by filtering contaminated ambient air or by providing a clean source of air.

  4. NIOSH • National Institute for Occupational Safety and Health • Federal agency responsible for conducting research and making recommendations to prevent workplace injuries and illnesses. • Helps to assure safe and healthy working conditions • National Personal Protective Technology Laboratory (NPPTL) is the division of NIOSH responsible for respirator certification. • NIOSH-approved respirators are marked with the manufacturer’s name, the part number, the type of protection (for ex., N95) and the acronym, NIOSH.

  5. N95 Respirator-NIOSH Requirements

  6. N95 Respirators • Used to protect against infectious aerosols produced when working with microorganisms, such as Rabies virus and Mycobacterium tuberculosis • Do not provide protection from chemicals, gases or vapors. Other respirator types are required for protection against chemical vapors. • The “N” designation indicates that the respirator is not resistant to oil. • Other respirator types may begin with an “R” or “P” • R95 respirators: Filter 95% of airborne particles and are somewhat resistant to oil • P95 respirators: Filter 95% of airborne particles and are strongly resistant to oil

  7. N95 Respirators • Primary respirator type used at Georgia Public Health Laboratory • Filter 95% of airborne particles that are 0.3 microns in size • N95 Respirator Assigned Protection Factor (APF) = 10 • An APF of 10 means that type of respirator (if used properly) can be safely used in an atmosphere that has a hazardous concentration of up to 10 times the Permissible Exposure Limit (PEL) for that hazard. • Powered Air Purifying Respirators (PAPRs) APF= 1000 • Provide a significantly higher level of protection as compared to disposable, tight-fitting N95 respirators

  8. Surgical Masks • Can not replace a NIOSH-approved respirator • Only prevent the release of infectious aerosols from the individual, while N95 respirators filter aerosols prior to inhalation by the individual.

  9. Respirator Donning and Doffing • Don: to put on • Doff: to remove or take off

  10. General Donning Procedure • When putting on a respirator (donning), complete the following: • Ensure that the respirator is the same manufacturer, model, and size on which you were fit tested. • Note: Review model and size information on your fit test form to ensure that it is consistent with your respirator. • Review the appropriate manufacturer’s instructions specific to the respirator model in use to ensure that you are properly trained on donning the respirator. • Inspect the respirator for damage prior to each use. • Follow the manufacturer’s instructions for putting on the respirator and performing the seal check procedure.

  11. Donning Procedure Example3M 1860 Respirator • Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang freely below your hand. • Position the respirator under your chin with the nosepiece up. Pull the top strap over your head resting it high at the top back of your head. Pull the bottom strap over your head and position it around the neck below the ears. • Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose by pushing inward while moving your fingertips down both sides of the nosepiece. • Perform a user Seal Check prior to each use.

  12. Seal Check Procedure Example3M 1860 Respirator • Check the respirator-to-face seal by placing both hands completely over the respirator and exhaling slowly for ~10 seconds. Repeat above step and inhale for ~10 seconds instead of exhaling. • Be careful not to disturb the position of the respirator. • If air leaks around the nose, readjust the nosepiece as described in the third step of the 3M 1860 Donning Procedure. If air leaks around the respirator edges, work the straps back along the sides of your head. • If you can not achieve a proper seal, try repeating this procedure with a new respirator. After additional attempts, do not enter the isolation or treatment area. • Notify your supervisor.

  13. Doffing Procedure Example3M 1860 Respirator • In order to remove an N95 respirator, complete the following steps: • With gloved hands, cup the respirator in hand to maintain its position on face. Keep in mind that the contaminated area is across the front of the respirator. • Pull the bottom strap over head. • While holding the respirator in position, pull top strap over head and remove the respirator. Note: This procedure is specific to the 3M 1860 model of N95 respirators. Review and follow the manufacturer’s instructions for the respirator model in use in your area.

  14. Other respirator types • PAPR (Powered Air Purifying Respirator) is a loose-fitting respirator • Use is required if employee has facial hair that interferes with the respirator-to-face seal • Perform Seal and Damage Check prior to each use. • PAPR is equipped with breathing tube, chargeable battery, filter and filter gasket that must be inspected prior to each use. • Don/Doff, cleaning, maintenance, and storage must be performed according to manufacturer’s instructions. Reminder: Complete review of the PAPR powerpoint training.

  15. Half-Face Respirator • Type of protection depends upon cartridge type • Charcoal cartridge protects against chemical vapors (Note: N95 respirators do not have this capability.) • Establish a cleaning and storage schedule according to manufacturer’s instructions.

  16. Respirator Storage • Store in clean areas only—not in contaminated areas. • Use plastic containers and/or ziploc bags to protect against... • Contamination and dust • Excessive temperatures and moisture • Deformation • Damage

  17. Medical Clearance • Prior to respirator fit testing • OSHA requirement • Employees with asthma are to use PAPRs or loose-fitting respirators instead of tight-fitting respirators • Complete GPHL Proof of Medical Clearance Form Note: Medical clearance is at employee’s expense • Indicate on the aforementioned form if you waive this clearance

  18. Respirator Fit Testing • Respirator training and fit testing are both required annually and before initial use of respirator • Must be repeated if the user experiences significant changes in physical conditions, such as weight loss or gain, and surgery or injury to face

  19. Respirator Assessment • Access and complete the Respirator Exam: • After you have reviewed the PAPR training powerpoint in SABA • By closing the training window(s) and clicking on the Respirator Exam link • Respirator Fit Testing is coordinated by GPHL Safety Officer. Fit Testing: Quantitative, On-Site -or- Qualitative, Off-Site Contact: LaTonya Clay, Ph.D. Email: laclay@dhr.state.ga.us

More Related