Calculele orientate de distributie pentru CET Sud, Bucuresti

Calculele orientate de distributie pentru CET Sud, Bucuresti. Twinning Project RO 2006 / IB / EN / 08 “Implementation and enforcement of the environmental acquis focussed on environmental noise - Phase II”. Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 1 – 34. Surse de masurare.

donoma
Download Presentation

Calculele orientate de distributie pentru CET Sud, Bucuresti

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calculele orientate de distributie pentru CET Sud, Bucuresti Twinning Project RO 2006 / IB / EN / 08 “Implementation and enforcement of the environmental acquis focussed on environmental noise - Phase II” Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 1 – 34

  2. Surse de masurare Masuratori efectuate joi, 10 aprilie 2008 Au fost inventariate: 9 surse de zgomot tip punct 5 orificii de iesire deasupra acoperisului 2 motoare pentru hote de absorbtie (date initiale 4)7 surse de zgomot tip suprafata 2 turnuri de racire (date initiale 3) hala motoarelor acoperis hala motoarelor suprafata ferestrelor hala motoarelor perete exterior hala motoarelor aerisirea din acoperis In modelul de calcul au fost introduse in total 16 surse de zgomot. Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 2

  3. Locatia CET Sud (extras planul orasului Bucuresti) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 3

  4. Locatia CET Sud (imagine Google Earth) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 4

  5. Locatia CET Sud (imagine Google Earth) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 5

  6. Harta zgomot industrial Bucuresti noapte (extras) 55 – 60 dB (A) 60 – 65 dB (A) 65 – 70 dB (A) 70 – 75 dB (A) 75 – 80 dB (A) 80 – 85 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 6

  7. Harta zgomot industrial Bucuresti (extras) 55 – 60 dB (A) 60 – 65 dB (A) 65 – 70 dB (A) 70 – 75 dB (A) 75 – 80 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 7 80 – 85 dB (A)

  8. Surse de zgomot Tip punct 1 LW = 124 dB (A) Tip suprafata 3 LI = 89,1 dB (A) Scara, in spatele peretelui Izolare medie a peretelui R´W = 25 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 8

  9. Surse de zgomot Tip punct 1 LW = 124 dB (A) Tip suprafata 3 LI = 89,1 dB (A) Scara, in spatele peretelui Izolare medie a peretelui R´W = 25 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 9

  10. Surse de zgomot Tip punct 3 Tip punct 2 Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 10

  11. Surse de zgomot Tip punct 2 Orificiu de evacuare deasupra acoperisului (diametru 80 cm) LW = 115 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 11

  12. Surse de zgomot Tip punct 3 Orificiu de evacuare deasupra acoperisului (diametru 30 cm) LW = 94 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 12

  13. Surse de zgomot Tip punct 4 Aorificiu deasupra acoperisului (diametru 60 cm) LW = 91 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 13

  14. Surse de zgomot Tip punct 5 Orificu evacuare deasupra peretelui (diametru 60 cm) LW = 100 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 14

  15. Surse de zgomot Tip punct 6 motor 1 – hota (masurat la 6 m distanta) LW = 119 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 15

  16. Surse de zgomot Tip punct 7 motor 2 - 4 – hota (masurat la 6 m distanta) LW = 110 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 16

  17. Surse de zgomot Tip suprafata 2 si turn de racire 1 si 2 LW“= 86 dB (A) m2 Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 17

  18. Surse de zgomot Tip suprafata 3 Turn de racire 3 LW“= 86 dB (A) m2 (suprafata libera, 2,5 m inaltime) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 18

  19. Surse de zgomot Tip suprafata 3 Turn de racire 3 LW“= 86 dB (A) m2 (suprafata libera, 4,5 m inaltime) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 19

  20. Surse de zgomot Tip suprafata 1 Hala motoarelor acoperis Nivel mediu interior Li = 89 dB (A) Izolare medie a acoperisului R´W = 25 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 20

  21. Surse de zgomot Tip suprafata 1 si 2 Hala motoarelor – acoperis si ferestre Nivel mediu interior Li = 89 dB (A) Iyolare medie acoperis R´W = 25 dB (A) Izolare medie fereastra R´W = 20 dB (A) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 21

  22. Surse de zgomot Tip suprafata 5 Hala motoarelor acoperis (suprafata libera) Tip suprafata (masurat la deschidere) LW“= 81 dB (A) m2 Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 22

  23. Calcul de distributie a zgomotului - Plot IO 3 IO 2 EMP 2 EMP 1 Limita intreprinderii IO 1 – Hotel Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 23

  24. Calcul de distributie a zgomotului - Plot Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 24

  25. Concluzii – Rezultate CET - Sud Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 25

  26. Lista de prioritati – IO 1 Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 26

  27. Lista de prioritati – IO 2 Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 27

  28. Lista de prioritati – IO 3 Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 28

  29. Obiective plan de actiune zgomot industrial Propuneri Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 29

  30. Obiective plan de actiune zgomot industrial Masuri pe termen scurt pentru CET-uri: Masuratori orientative Reducere a zgomotului la cele 2 pana la 3surse cele mai puternice de zgomot Contingentarea suprafetelor (planificare) Propunere Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 30

  31. Obiective plan de actiune zgomot industrial Masuri pe termen scurt pentru CET Sud: Masuratori orientative (efectuate) Reducerea zgomotului la cele 2 pana la 3 cele mai puternice surse de zgomot - amortizoarele de zgomot PSQU 1 si 2- incapsularea hotei 1 (reducere > 5 dB(A) Consideratii contingentarea suprafetelor Propuneri Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 31

  32. Obiective plan de actiune zgomot industrial Masuri pe termen mediu pentru CET Sud: Reducerea zgomotului la urmatoarele surse - amortizoarele de zgomot PSQU. 3 pana la 5- incapsularea hotelor 2 pana la 4- perete fonoabsorbant in zona orificiilor hotelor Ulterior elaborarea unei expertize tehnice speciale de zgomot (daca este cazul) Crearea bazei legale necesare Propunere Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 32

  33. Alte prezentari Observatii suplimentare referitoare la C.E.T GROZAVESTI; Bucuresti Posibilitati de reducere a zgomotului Exemple de contingentare a suprafetelor Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 33

  34. Observatii la foliile 4 si 5 Nivel de evaluare prea ridicat in zona rezidentiala; Contradictie cu valoarea la gard din legislatia romana- 65 / 65 dB(A) la granita intreprinderii (introdus 65 / 65 dB(A)/m2 , adica Lr,den = 76 dB(A)la gard); Suprafata totala se introduce cu valoare uniforma, nici o diferentiere: consecinta – contingentarea suprafetelor. (planurile de imisie a zgomotului) Dr. Richard Neuhofer / TÜV NORD Umweltschutz / T 34