1 / 23

Superconducting Generators for Large Wind Turbines

Superconducting Generators for Large Wind Turbines. markus.mueller@ed.ac.uko.keysan@ed.ac.uk Institute for Energy Systems The University of Edinburgh. Markus Mueller – Ozan Keysan. 24/11/2011. Wind Turbines: Constantly Growing. European Wind Energy Association. Offshore Wind Turbines.

dionne
Download Presentation

Superconducting Generators for Large Wind Turbines

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Superconducting Generators for Large Wind Turbines markus.mueller@ed.ac.uko.keysan@ed.ac.uk Institute for Energy Systems The University of Edinburgh Markus Mueller – Ozan Keysan 24/11/2011

  2. Wind Turbines: Constantly Growing European Wind Energy Association

  3. Offshore Wind Turbines In 2020, 85% of offshore wind turbine installations will be larger than 5 MW BARD 5MW Global Offshore Wind Energy Markets and Strategies,2009

  4. Wind Turbines: Constantly Growing • How big? • UpWind Project: A 20 MW Wind Turbine is Feasible www.upwind.eu

  5. Limiting Factors for Large Wind Turbines • Nacelle Mass • Overall Reliability www.upwind.eu

  6. Reliability of Wind Turbines ~1MW, 1500 onshore turbines Hahn, B., & Durstewitz, M. (2007). Wind Energy-Reliability of Wind Turbines.

  7. Three Stage Gearbox + DFIG • PROS • Low power electronics cost • Mature technology • Off-the-shelf components • CONS • Gearbox cost & mass • Less Efficient • Gearbox failures RePower 6 MW, 12 rpm http://www.repower.de/en/wind-power-solutions/wind-turbines/6m

  8. Direct Drive: PMG • PROS • Minimum Moving Parts • High Efficiency • CONS • Large Diameter • High Cost TheSwitch 3.8 MW, 21 rpm 6.5 m diameter 81 tonnes

  9. Direct Drive: EESG • PROS • Easier to manufacture • Reduced cost • Controllable field • CONS • Increased Mass • Brushes on rotor Enercon 6 MW, 13 rpm 10 m diameter 220 tonnes www.enercon.de

  10. Single Stage Gearbox + PMG • PROS • Reduced magnet cost • Reduced generator mass • High efficiency • CONS • Reduced reliability(?) • Gearbox Cost & Mass WinWind 3MW Multibrid Areva 5MW www.winwind.com www.areva-wind.com

  11. Direct-Drive Solutions Enercon 4.5 MW, 13 rpm 220 tonnes Harakosan 1.5MW,18 rpm,47 tonnes All data available at goo.gl/ZZivv (*) D. Bang et.al. “Review of Generator Systems for Direct-Drive Wind Turbines,” 2008,

  12. Direct-Drive Solutions All data available at goo.gl/ZZivv (*) D. Bang et.al. “Review of Generator Systems for Direct-Drive Wind Turbines,” 2008,

  13. Power Applications • Fault Current Limiter • Quick response • Reduced volume • Cheaper to operate • Transmission Lines • High efficiency • 10 times more power from the same conduit area Courtesy of AMSC, InnoPower Superconductor

  14. Power Applications : Electrical Machines • Converteam (ALSTOM): 5 MW HTS (Smaller than the 2.5 MW Load Motor) • Siemens: 400 kW Courtesy of Siemens, Converteam (ALSTOM)

  15. Power Applications : Electrical Machines 75% More Power 40% Lighter 36.5 MW, 120 rpm Ship Propulsion Motor Designed by AMSC for U.S. Navy Courtesy of AMSC

  16. Reliability? Issues with Superconducting Generators SeaTitan AMSC, 10 MW, 10 rpm Direct-drive superconducting generator • Cooling System • Cryogenic Couplers • Electric Brushes • Transient torques on SC • AC losses on SC wire

  17. Advantages of the Concept • Stationary SC Coil • No Cryogenic Coupler • No Brushes • No Transient Torque on SC • Simplified Cooling, Isolation • DC Field • No AC losses • Maximized Current

  18. Transverse Flux HTSG • Easy to build • Modular Rotor • Stationary SC coil • Single SC winding • Minimal SC wire length • Simple cooling • No torque on SC

  19. 3D FEA Verification

  20. Main Specifications

  21. Linear Prototype • Easy to build • Modular Rotor • Stationary SC coil • Single SC winding • Minimal SC wire length • Simple cooling • No torque on SC

  22. Next Stage- Large Diameter Generator • Power density further increased • Two independent machines • Self-supporting structure • Easy to maintain SC

  23. Publications • "A Homopolar HTSG Topology for Large Direct-Drive Wind Turbines", Keysan O., and Mueller M., 2011. IEEE Transactions on Applied Superconductivity, 21(5), 3523 - 3531. doi:10.1109/TASC.2011.2159005. • "Superconducting Generators for Renewable Energy Applications", Keysan O., and Mueller M., 2011, IET Renewable Power Generation Conference, Edinburgh. • "A Transverse Flux High-Temperature Superconducting Generator Topology for Large Direct Drive Wind Turbines", Keysan O., and Mueller M., 2011. Superconductivity Centennial Conference, 2011, Den Haag, The Netherlands.

More Related