1 / 21

RAV MAMAD (RM)

RAV MAMAD (RM). A Universal Modular (Assemble & Dismantle) Indoor Protection System. info@defensetechs.com www.defensetechs.com. Registered Patent. The Present Situation & Problem

dex
Download Presentation

RAV MAMAD (RM)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RAV MAMAD (RM) A Universal Modular (Assemble & Dismantle) Indoor Protection System. info@defensetechs.comwww.defensetechs.com

  2. Registered Patent The Present Situation & Problem There is a ballistic threat of high-trajectory weapons aimed towards 1/3 of the Israeli CIVILIAN population (north and south). The present ALERT time does provide enough time for the citizens to reach a protected shelter. Building a “Protected Room” (MAMAD) is not practical in many of the apartments and houses. info@defensetechs.comwww.defensetechs.com

  3. Registered Patent A concrete ceiling structure hit by a rocket info@defensetechs.comwww.defensetechs.com

  4. A tiled roof and a Ravitz ceiling house hit by a rocket. info@defensetechs.comwww.defensetechs.com

  5. The Solution An indoor protection system created by a metal protective layer, installed and adjusted to the ceiling and wall of a pre-chosen room (or space). A defense room plan (ceiling + wall) info@defensetechs.comwww.defensetechs.com

  6. The standard RM withstands a direct hit of a “Quassam II” light missile and the “Katyusha” 122mm and 120mm Mortar. The protection level can be upgraded according to the threat defined by an additional layer and without the need to dismantle the base. info@defensetechs.comwww.defensetechs.com

  7. The Protective System The ceiling and “threatened” walls inside the pre-chosen room are covered with constructive steel panels, combined to create a protective layer against shrapnel and shock waves. The panels are manually inserted and installed upon supportive hidden columns in the corners of the room. By this action, it is not required to reinforce the complete structure of the house / apartment, as the weight is diverted to the floor and at its strongest points. info@defensetechs.comwww.defensetechs.com

  8. The Protective System Combining the panels, creates a strong but flexible (to a limit) continuous surface, enabling it to resist and block the explosion effects. info@defensetechs.comwww.defensetechs.com

  9. Protected room by “Rav mamad” Protection element Plaster cover Supporting Steel columns info@defensetechs.comwww.defensetechs.com

  10. Protected room by “rav mamad” Protection element A wall protection option info@defensetechs.comwww.defensetechs.com

  11. IMPS SIMULATIONS info@defensetechs.comwww.defensetechs.com

  12. IMPS SIMULATIONS 1.Original Condition info@defensetechs.comwww.defensetechs.com

  13. IMPS SIMULATIONS 2. Wall Protection info@defensetechs.comwww.defensetechs.com

  14. IMPS SIMULATIONS 3. IMPS Ceiling Supporting Stem info@defensetechs.comwww.defensetechs.com

  15. IMPS SIMULATIONS 5. IMPS Ceiling info@defensetechs.comwww.defensetechs.com

  16. IMPS SIMULATIONS 5. Paneling Walls & Columns With Chemistry info@defensetechs.comwww.defensetechs.com

  17. IMPS SIMULATIONS 6. Complete IMPS- Inside View info@defensetechs.comwww.defensetechs.com

  18. Advantages • Creates a possibility to form a protected zone in “unqualified” for reinforcement (construction) structures. • Modular, suitable for any room in any structure. • License free • Quick installation ( 1 day for protection, 1 day for finishes). • Upgrading ability (threat related). • Cost Effective info@defensetechs.comwww.defensetechs.com

  19. From the report made for the test of durability of protection layers for indoor room and spaces towards direct rocket hit. “...on January 8th, 2007 a test was conducted for checking the durability of IMPS – indoor modular protection system, towards a direct rocket hit…” “…the test was done at the Rosh HaAyin Quarries for the Mifram co. by Tamar co. and supervised by YY (Yaacov Yerushalmi) info@defensetechs.comwww.defensetechs.com

  20. “… the test included 2 static operational demolitions of rocket simulator containers. 1. 5Kg TNT upon 8cm thick concrete surface. 2. 7.5Kg TNT upon 20CM cement blocks “… the 2 explosions results showed success for the IMPS as the system did not collapse, did not tear and no fragments or shrapnel penetrated beyond the info@defensetechs.comwww.defensetechs.com

  21. Protection of commercial facility info@defensetechs.comwww.defensetechs.com

More Related