1 / 55

Column Chromatography

Column Chromatography. Nina Salamah, MSc., Apt. Kromatografi Kolom Sederhana. Bergerak / aliran karena gaya grafitasi ↓ Pemilihan fase diam + fase gerak ↓ Kepolaran ↓ Pita-pita kromatogram ↓ Terbentuk fraksi-fraksi ↓ Dianalisis dengan KLT / KK↓. Pengisian Kolom.

deleonm
Download Presentation

Column Chromatography

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Column Chromatography Nina Salamah, MSc., Apt

  2. Kromatografi Kolom Sederhana Bergerak / aliran karena gaya grafitasi ↓ Pemilihan fase diam + fase gerak ↓ Kepolaran ↓ Pita-pita kromatogram ↓ Terbentuk fraksi-fraksi ↓ Dianalisis dengan KLT / KK↓

  3. Pengisian Kolom • pengisian kolom homogen • fase diam ukuran sama • fase diam bentuk homogen • bebas gelembung udara Fase diam Pasir Kapas / glass wool Tehnis : fase diam + pelarut → bubur (f. gerak)

  4. Klasifikasi Sistem Kromatografi

  5. LIQUID COLUMN CHROMATOGRAPHY A sample mixture is passed through a column packed with solid particles which may or may not be coated with another liquid. With the proper solvents, packing conditions, some components in the sample will travel the column more slowly than others resulting in the desired separation.

  6. Principles of Separation on a column

  7. Principles of Separation

  8. Principles of Separation

  9. Principles of Separation

  10. Principles of Separation

  11. Principles of Separation

  12. Principles of Separation

  13. Pemisahan pada Kromatografi Kolom

  14. Aliran fase gerak pada kolom Gravitasi Pressure/tekanan Vacum pompa

  15. How does reverse phase chromatography compare to normal phase chromatography ?

  16. Normal Phase Column Chromatography … • The stationary phase is POLAR • The more polar component interacts more strongly with the stationary phase • The more polar component moves more slowly. • The non-polar component moves more rapidly.

  17. Reverse Phase Chromatography… Silica is alkylated with long chain hydrocarbon groups, using 18 carbons long. This is usually referred to as C-18 silica.

  18. Reverse Phase Column Chromatography…. • The stationary phase (column packing) is nowNON-POLAR • Non-polar compounds will move more slowly because they are attracted to the column packing. • The more polar component moves more quickly down the column. • Polar solvents, such as water and methanol are used in reverse phase chromatography • Used mainly in columns, such as HPLC

  19. Diagram of Simple Liquid Column Chromatography

  20. FOUR BASIC LIQUID CHROMATOGRAPHY The 4 basic liquid chromatography modes are named according to the mechanism involved:  1. Liquid/Solid Chromatography (adsorption chromatography) A. Normal Phase LSC B. Reverse Phase LSC  2. Liquid/Liquid Chromatography (partition chromatography) A. Normal Phase LLC B. Reverse Phase LLC  3. Ion Exchange Chromatography  4. Gel Permeation Chromatography (exclusion chromatography)

  21. Types of Chromatography

  22. LIQUID SOLID CHROMATOGRAPHY Normal phase LS Reverse phase LS d- d+ Si - O - H 30 m Silica Gel The separation mechanism in LSC is based on the competition of the components of the mixture sample for the active sites on an absorbent such as Silica Gel.

  23. LIQUID SOLID CHROMATOGRAPHY OH HEXANE Si - OH OH OH CH CH 3 3 C-CH CH - C 3 3 CH 3 CH 3 CH 3

  24. WATER-SOLUBLE VITAMINS

  25. WATER-SOLUBLE VITAMINS

  26. NCCH CH OCH CH CN(Normal) 3 2 2 2 CH (CH ) CH (Reverse) 3 2 16 3 LIQUID-LIQUID CHROMATOGRAPHY ODPN (oxydipropionylnitrile) Normal Phase LLC Reverse Phase LLC The stationary solid surface is coated with a 2nd liquid (the Stationary Phase) which is immiscible in the solvent (Mobile) phase. Partitioning of the sample between 2 phases delays or retains some components more than others to effect separation.

  27. - + SO Na 3 ION-EXCHANGE CHROMATOGRAPHY Separation in Ion-exchange Chromatography is based on the competition of different ionic compounds of the sample for the active sites on the ion-exchange resin (column-packing).

  28. Types of Ion Exchange Resins

  29. Chromatography • Conditions associated with each kind of chromatography • Ion exchange chromatography • Organic cation exchange resins involve crosslinked polystyrene containing either SO3- or COO- functional groups with an associated cation • Organic anion exchange resin involve • crosslinked polystyrene containing NH3+ • functional groups with an associated anion The affinity of dissolved ions for the resin varies with the ion and the composition of the solution

  30. nRzSO3–H+ + Mn+ (RzSO3)nM + nH+ • nRzCO2–H+ + Mn+ (RzCO2)nM + nH+ • nRzNR3+OH-+ An- (RzNR3)nA + nOH-

  31. MECHANISM OF ION-EXCHANGE CHROMATOGRAPHY OF AMINO ACIDS pH2 - + + SO Na H N 3 3 COOH Ion-exchange Resin + - H N SO 3 3 - COO pH4.5 + Na

  32. Chromatography of Amino Acids

  33. Some Applications of Ion Exchange Chromatography • Purifications a mixed bed cation-anion exchanger remove salts (ex CaCl2) from water by exchanging them for H2O :Deionization of water • Concentrations The concentration of trace elements in seawater. • Analytical Separations Separations of metal ions and amino acid or halide ions

  34. SIZE EXCLUTION CHROMATOGRAPHY Gel-Permeation Chromatography is a mechanical sorting of molecules based on the size of the molecules in solution. Small molecules are able to permeate more pores and are, therefore, retained longer than large molecules.

  35. SIZE EXCLUTION CHROMATOGRAPHY • Molecules that can penetrate the gel particles are separated based on size and shape. Others pass straight through the column. • Gel filtration chromatography : mobile phase is water. • Gel permeation chromatography : mobile phase is an organic solvent. • Sephadex is popular molecular-sieve material 4 the separation of proteins.

  36. SOLVENTS Polar Solvents Water > Methanol > Acetonitrile > Ethanol > Oxydipropionitrile Non-polar Solvents N-Decane > N-Hexane > N-Pentane > Cyclohexane

  37. Kekuatan elusi pelarut pada silika dan polaritas pelarut

  38. Schematic of a chromatogram

  39. PARAMETER PEMISAHAN DALAM KROMATOGRAFI KOLOM 1. KAPASITAS Kapasitas menggambarkan kemampuan fase diam dalam menahan analit. Jika waktu tambat lama, berarti kapasitasnya besar. 2. SELEKTIVITAS Selektivitas menggambarkan kemampuan fase diam untuk dapat memisahkan suatu campuran senyawa. Semakin besar nilai , campuran senyawa semakin terpisah. 3. RESOLUSI Resolusi menggambarkan kemampuan kolom dalam memisahkan campuran senyawa 4. JUMLAH PLATE TEORITIS Jml pelat teoritis N, dalam kolom dapat diketahui dari hasil kromatogram. 5. TINGGI PLATE TEORITIS = H HETP = High Equivalent to A Teoritical Plate Adl : ukuran yang menunjukkan ruang yg ditempati oleh setiap pelat teoritis.panjang kolom

  40. HETP = L/N L = PANJANG KOLOM

  41. Adjusted Retention Time tr = retention time tm = min. time for unretained mobile phase to travel through column In GC tm is the time CH4 takes to travel through the column Relative Retention Capacity Factor

  42. Resolution

  43. Nilai R yg baik > 1,5. Jika R = 1 masih tjd tumpang tindih di antara kedua puncak  2% Untuk memperbaiki R : 1. memperbesar  tR = t2 – t1 kolom diperpanjang jumlah fase diam diperbesar manipulasi faktor pemisahan pengoptimalan suhu pilih f.d dan f.g yang cocok 2. Memperkecil lebar puncak, W pilih ukuran fase diam kecil (halus) dan pengisian dalam kolom diperbaiki (seragam dan kompak. Kecepatan alir fase gerak optimum Kurangi dead space dalam kolom Kurangi jumlah sampel Diameter kolom diperkecil.

  44. Resolution w = peak width at the baseline between tangents drawn to the steepest parts of the peak w1/2 = measured at ½ the peak height

  45. A peak with a retention time of 407 s has a width at the base of 13 s. A neighboring peak is eluted at 424 s with a width of 16 s. Find the resolution for these two components.

  46. Chromatography • Chromatographic column theory of packed columns • The effect of column efficiency and column selectivity on resolution Poor resolution because of poor column efficiency Good resolution because of good column efficiency, although column selectivity is not great Good resolution because of good column selectivity, although column efficiency is poor Poor resolution because of poor column selectivity, although column efficiency is good

  47. Theories ofElution Chromatography some zone broadening zone separation

  48. Plate height: constant of proportionality between the variance (s2)of the band and the distance traveled (x) Smaller plate height = narrow peaks = better separations Plate height (H) Number of plates (N)

More Related