Single Loop Analogue addressable fire control Panel

Single Loop Analogue addressable fire control Panel. Single Loop Fire Control Panel. 1 Loop not expandable Panel. Certified according to EN54-4 ed EN54-2 by IMQ. Up to 240 devices on the Loop. LCD Graphic display. Navigation keys . System status leds.

deanna
Download Presentation

Single Loop Analogue addressable fire control Panel

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Single Loop Analogue addressable fire control Panel

  2. Single LoopFire Control Panel • 1 Loop not expandable Panel • Certified according to EN54-4 ed EN54-2 by IMQ • Up to 240 devices on the Loop • LCD Graphic display • Navigation keys • System status leds • 1 Extinguish channel optional card (certified according EN 12094-1) • Low Cost

  3. Single LoopFire Control Panel • New generation technology, software selectable protocol • Up to 240 devices on the Loop • Self addressing feature • Up to 2000 m loop length • Open Line or Loop selectable • Loopdiagnosticfeature (detectors contaminationlevel, Loopsignalquality, real time value) • Eachdeviceequiped with a short circuit Isolator

  4. Single LoopFire Control Panel • 30 Zones • 1,4 A Switching Power supply • Thermal compensated battery charger • Batterysupervision (efficiencycheck)

  5. Single LoopFire Control Panel • RS232 port for UP/Downloading • Self restorable fuses protect outputs and battery • Battery disconnection in case of deep discharge • 24V Output for external devices feed • Supervised Dialer Output • 1 A Supervised Alarm Output • 1 Supervised + 1 dry contact fault output • RS485 BUS for up to 4 repeater connection. On each repeater event view and scroll, reset silence etc.

  6. Single LoopFire Control Panel Using the LCD Graphic display the start up and all the requestedprogramming can be easilydone from the front panel

  7. Single LoopFire Control Panel Using PC Software a clearindication of Loopdevices which report the exact connection sequenceisavailable With a double click device’sparameters can be accessed

  8. Single LoopFire Control Panel Real Time monitor of eachdevice state isavailablewhere a wide range of information are reported

  9. Single LoopFire Control Panel Up to 8 timerswith yearlyprogramming are available

  10. Single LoopFire Control Panel Logicequationdefinable by installer to fulfilleachinstallationrequirement

  11. Single LoopFire Control Panel SMARTLetLoose/ONE • Optional Card for single channel extinguish system management

  12. Single LoopFire Control Panel • CPD EN12094-1 Approved

  13. Single LoopFire Control Panel • 1 supervised input for manual release • 1 supervised input for stop release • 1 supervised input for pressure switch for baloon supervision and release confirm • 1 supervised output for Pre Extinguish signalling • 1 supervised output for released signalling

  14. Single LoopFire Control Panel • SmartLight/G : Up to 240 loop devices, 30 Zones • SmartLight/S : up to 64 loop devices, 16 zones • SmartLetLoose/ONE : single channel gas extinguish management card