1 / 23

SP600: General Overview & Update

SP600: General Overview & Update. THE NEW BENCHMARK OF DRIVE VALUE. SP600: Overview. Product Highlights: Horsepower Ratings: 0.5 to 200 HP 0.5 - 10 HP, 240V 0.5 - 50 HP, 480V 0.5 - 20 HP, 600V Graphical ICON based LCD keypad Local keypad is removable Remote keypad rated NEMA 4/12

dayo
Download Presentation

SP600: General Overview & Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SP600: General Overview & Update THE NEW BENCHMARK OF DRIVE VALUE

  2. SP600: Overview • Product Highlights: • Horsepower Ratings: 0.5 to 200 HP • 0.5 - 10 HP, 240V • 0.5 - 50 HP, 480V • 0.5 - 20 HP, 600V • Graphical ICON based LCD keypad • Local keypad is removable • Remote keypad rated NEMA 4/12 • Built-in dynamic braking transistor circuit • On-drive mounting of low-energy braking resistors ( 0.5 to 20 HP only ) • Remote resistors for higher duty cycles • Distinct Enclosure Packages: • NEMA 1 Wall or Machine Mount • Through cabinet Flange Mount • NEMA 4X/12 • Bookshelf …… NEW! Frame B ( 3 to 5 HP ) Frame 3 ( 30 - 50 HP )

  3. SP600: Packaging • Flange Mounted Enclosures: • Convert from NEMA 1 to IP20 by removing top ventilation cover • Expose the heatsink out the rear of the cabinet for external heat dissipation. • Reduce cabinet size • Reduce cost of cabinet cooling • IP20 conversion allows operation at ambient cabinet temperature of 50°C • Mounting hardware and gasket included with every flange mount unit. • Heatsinks are painted with corrosion protective paint for survivability in harsh environments. • Only a $40.00 List premium over standard wall mount models. SP600 : B-Frame ( 3 to 5 HP )

  4. SP600: Packaging • NEMA 4X / 12 ( IP66 ) • Stand-alone Drives & Modified Standard Drives • Washdown Enclosures • Dust-tight Enclosures • Provides contamination-FREE operation • Stand-alone • LCD OIM on NEMA 4X/12 models will be embedded into the drive’s cover as an assembly to assure wash-down integrity is maintained throughout the products life • Modified Standard • Integral fused disconnect switch and full functioning LCD OIM • INDUSTRIES • Food • Beverage • Chemical • Aggregate • Wastewater • Water Treatment

  5. SP600: Packaging • NEMA 1 Bookshelf ( IP30 ) • Stand-Alone Drives • Ratings from 20 to 50 HP • Wall or Panel mounted installation • Common hardware and software options as NEMA style SP600 • Built-in IGBT circuit for braking • Unique Features: • Cassette for I/O connections • Mix & Match I/O for custom application needs • I/O expansion • Zero Stacking saves space in panel mounted applications

  6. SP600: Performance • Sensorless Vector Control • Standard configuration, Out-of-the-box! • Good Low Speed Torque Production • Good Constant Torque and Constant Hp performance • Note that in the case of a 5Hp SP600 and a standard XE motor, how well the 3 second overload limit of 150% breaks over sharply. • In this example the Drive has an 8.0 Amp continuous rating and the motor has a 6.4 Amp Nameplate. • 3 Methods of Motor Tuning • Calculation based on motor data • Static tune by current injection • Dynamic tune by running motor

  7. SP600: Performance • V/Hz & SVC Operation • Common Overload Ratings • 110% OL for 60 seconds • 150% OL for 3 seconds • 400% OL scaling for over-sizing the drive while maintaining appropriate drive & motor protection • Select V/Hz for: • Centrifugal Fans & Pumps • Multiple motors / single drive • Punch Presses • Select SVC for: • Positive Displacement Pumps • Unit Conveyors, one drive / motor • Extruders • Mixers Torque production is maintained in SVC operation at speed settings of 0.5 Hertz down to 0.0 Hertz. The limitation of 0.5 Hertz indicated in the graph above is to identify the lowest level of speed operation where predictable speed control and regulation can be expected.

  8. SP600: Performance • Target Industries: • Aggregate & Mining • Food Processing • Petrochemical • Plastic Processing • Water Treatment • Pollution Control • Target Applications: • Conveyors & Hoists • Fan & Pump installations with PI • Batch, Flow & Pressure regulation • Mixers & Extruders

  9. SP600: Braking • Dynamic (Snubber) Braking • Low-Energy Snubber Resistor kit mounts cleanly on the back of the drive’s heatsink • Does not affect depth dimension • Wires cleanly to DC Bus terminals with grommet to seal rear entrance • Ideal for; • fast stops ( low duty cycles ) • correction of speed overshoot • absorbing small line transients • DC Bus terminals also allow connections for larger, externally mounted resistors where higher duty-cycles or inertia’s are involved.

  10. SP600: Local OIM • Local LCD OIM • Operator Interface Modules • The LCD OIM can be purchased as a loose item or factory installed on certain models • World’s first ICON based drive interface • Start-up, Parameters, Control Source Select, Diagnostics, Memory, Display, Network & Password • Intuitive Parameter Grouping into 3 access levels: ( Basic is the default ) • Basic Access ( 30 parameters ) • Standard Access ( 60 parameters ) • Advanced Access ( 300+ parameters ) • Function Keys with both: • Pre-configured use in parameter setup • Customer configurable for operation

  11. SP600: Remote OIM • Remote LCD OIM • Operator Interface Modules • All of the same functionality as the Local OIM • When remote mounted, the Function Keys save users and OEM’s the cost and labor associated to pushbuttons and switches. • When used as an Operator Control for • Start / Stop & Jog Operation • Preset Speeds • Accel & Decel 2 selection • Drive / Machine / Process display • Speed in RPM, Ft/Min, Units / Hr • Load in Amps, Torque, Watts

  12. SP600: LCD OIM - Local & Remote models Operating Status Direction Indication Alarm Status Password Status Product Identification Speed Reference Source F-Key Operation F-Key Operation ICON Driven Main Menu and Identifier

  13. Configurable Function Keys Enter Key MOP Speed Control & Vertical Scroll Keys Forward / Reverse Operation Escape / Program Horizontal Scroll Keys Jog Operation Start Operation Stop Key & Fault Reset SP600: LCD OIM - Local & Remote models

  14. SP600: LCD OIM - Local & Remote models Display Icon allows operators to configure the OIM for language, monitoring, function keys and other considerations. Memory Icon allows operators to load and save different parameter sets into the OIM and, subse- quently, into the drive; or to restore factory-set defaults. Device Select Icon allows opera- tors to identify and select the drive or peripheral device from which to obtain data. Password Icon provides protec- tion against modification of any writeable parameter by an un- authorized user and select parameter access levels. Start Up Icon provides access to Quick Start utility that allows for Fast, easy set-up involving only Seven parameter groups. Parameter Icon provides quick Access to drive and peripheral- Component parameters. Control Source Icon allows Control and reference selection. Diagnostics Icon provides infor- mation on faults and alarms. Icons provide users an intuitive interface as well as a logical method of grouping access to drive functions and operations.

  15. SP600: LCD OIM • User Friendly Monitor Functions • Up to 3 Monitor Values can be displayed at one time during operation for simple viewing of process performance • Both Text and Unit Scaling are “user definable” for ultimate flexibility • Configure numerical values as well as text from Hertz to any value that can be related to motor operating speed, such as; • Gallons / Hr • Feet / Sec • Bagels / Min

  16. PowerMatched Motors LCD OIM LED OIM Serial Converter Cable PC Software Communication Cards mount inside SP600: Versatility

  17. SP600: Connections

  18. Control I/O SP600: Overview • Terminal Connections • 6 Digital Inputs ( sink or source) • 2 Form C Relay Outputs • 2 Analog Inputs • 0-10 V, 10 bit resolution • ± 10V bi-directional • 4-20 mA • 1 Analog Output • 0-10V, 10 bit resolution Input & Motor Power Terminals Frame 3 : 30 - 50 HP

  19. SP600: Connections • Network Connections • Common footprint modules • Easy installation • Networks include: • DeviceNet, ControlNet, EtherNet, Profibus, Interbus, RS485 and much, much more…...

  20. SP600: PC Configuration • Windows Explorer look and feel • Left side tree view • Right side parameter list • HTML help • Parameter Upload / Download • Configure parameter settings • Monitor I/O activity • Compare files • Monitor multiple drives when they’re on a Communication Network • DPI based • ControlNet, DeviceNet, Profibus, Interbus and many more • Supported PC Operating Systems • Windows 95/98/2000/NT

  21. SP600: Training Tools Our SP600 Drive simulator will help salespeople, distributors and users get a feel for the drive right on their PC! Each RDMM has 5 demos in his possession to perform regional training!

  22. SP600: Competitor Snapshot

  23. SP600: 0.5 to 50HP, and 75 HP by 2003

More Related