2704 v6 0 software june 2003
This presentation is the property of its rightful owner.
Sponsored Links
1 / 8

2704 V6.0 software - June 2003 PowerPoint PPT Presentation


  • 44 Views
  • Uploaded on
  • Presentation posted in: General

2704 V6.0 software - June 2003. Hardware compatibility New micro-board required New Features Boiler TDS functions Programmer enhancements Other little things to make life easier. Boiler TDS. What is Boiler TDS?

Download Presentation

2704 V6.0 software - June 2003

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


2704 v6 0 software june 2003

2704 V6.0 software - June 2003

  • Hardware compatibility

    • New micro-board required

  • New Features

    • Boiler TDS functions

    • Programmer enhancements

    • Other little things to make life easier


Boiler tds

Boiler TDS

  • What is Boiler TDS?

    • TDS (total dissolved solids) is the measurement of particles in a fluid. For example water in a steam boiler.

  • Why do we need to control it?

    • High TDS causes foaming on the surface of the water. This reduces boiler efficiency and contaminates the steam system.

Steam

Steam

TDS Probe

Continuous Blowdown

Water

Feedwater

Bottom Blowdown


2704 tds functions

2704 TDS Functions

  • TDS Measurement

    • TDS is derived from conductivity measurement in S/cm

    • New conductivity input module, order code TD

  • TDS Control

    • Continuous control

      • Temperature compensated TDS reading in PPM or [email protected]

      • Probe deterioration alarm

      • Reduced probe scale build up

      • Simple calibration functions

    • Timed bottom blowdown

      • Uses real time clock to initiate blowdown

      • Can be networked in multiple boiler installations

      • Complies with PM60 - UK standard concerning multiple boiler installations


2704 programmer

Profile 2

Profile 1

Profile 3

2704 Programmer

  • Ability to run Asynchronous Profiles

    • Up to 3 setpoint profiles

    • Each profile has its own timebase

    • 20 stored programs per profile

    • 16 Digital outputs per profile

    • Option “A” in Loops/Program field

  • Program Run Groups

    • Ability to store 20 groups

    • Common Run, Hold & Reset

  • Advanced Editing

    • Insertion/deletion of segments

    • Copy/paste of programs

  • Custom naming of digital events

  • Increase to 60 Synchronous Programs


Synchronous programmer

Loop 1

Loop 2

Loop 3

Synchronous Programmer

Run

Programmer

PSP1

PSP2

Hold

PSP3

Reset

Digital events x 16


Asynchronous programmer

Loop 1

Loop 2

Loop 3

PSP1 Profile x 20

PSP3 Profile x 20

PSP2 Profile x 20

Run

Program Groups

x 20

Hold

Reset

Asynchronous Programmer

Run

Hold

Reset

Digital events x 16

Run

Hold

Reset

Digital events x 16

Run

Hold

Reset

Digital events x 16


Other little things

Other Little Things

  • Patch Wiring

    • Any parameter can now be ‘soft’ wired

    • Available in Toolkit level 1

  • 32 Analogue operators in Toolkit level 2

  • 50 User values

    • 10 in standard 2704

    • 30 in Toolkit level 1

    • 50 in Toolkit level 2

  • New multiple input block

    • 6 inputs - average, max, min or sum of inputs

      • Can be used as 6 input OR or AND gate

    • 3 blocks in 2704

      • 1 in Toolkit level 1

      • 3 in Toolkit Level 2


Other little things continued

Other Little Things - Continued

  • 100 User text strings

  • 100 Master communications parameters

    • 16 Slave devices

  • Option for Local SP Ramp servo to WSP

  • Additional EI-Bisync parameters


  • Login