1 / 16

Abordagem ao exame

Abordagem ao exame. Pedro Silva. Curso de Tomografia Computorizada 04 de Fevereiro de 2012 . O que vamos abordar!. Posicionamento Limites Parâmetros Responsabilidades do técnico . TX. Limites de aquisição Modulação de dose . TX. T.T. O que queremos ver? Resolução espacial . T.T.

corina
Download Presentation

Abordagem ao exame

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Abordagem ao exame Pedro Silva Curso de Tomografia Computorizada 04 de Fevereiro de 2012

  2. O que vamos abordar! • Posicionamento • Limites • Parâmetros • Responsabilidades do técnico

  3. TX • Limites de aquisição • Modulação de dose

  4. TX

  5. T.T. • O que queremos ver? • Resolução espacial

  6. T.T. • FOV • Espessura de Corte • Sobreposição • Algoritmos

  7. TX pediátrico • Dose VS Exame conclusivo • Resolução temporal • Modulação de Dose • kV

  8. TX pediátrico

  9. CE urgência • Incremental • Helicoidal • Tempo de Aquisição • Dose

  10. CE urgência

  11. Pesc / TX / Abd / Pelv • Posicionamento • Aquisições • Injecções • Modulação de Dose

  12. Pescoço/tx/abd/pelv

  13. Jogo • 5 casos simples • 5 grupos • Jogo • Discussão

  14. Síntese conclusiva • Discussão do Jogo

  15. Bibliografia • ICRP - Internacional Commission on Radiological Protection; Managing patient dose in computed tomography. ICRP 87. Oxford. Pergamon.( 2000) • Mannudeep K. Kalra MD; Nausheen Naz MD; Stefania M.R. Rizzo MD and Michael A. Blake MRCPI; FRCR, FFR (RCSI); Computed Tomography Radiation DoseOptimization: Scanning Protocols and Clinical Applications of Automatic Exposure Control. Boston (2005) • European Guidelines on quality criteria for Computed Tomography. EUR 16262 (1999) • Nicholas Keat ;CT Scanner automatic exposure control systems, www.impactscan.org.(2005) • Lewis, Maria ; Principles and implementation of automatic exposure control systems in CT, www.impactscan.org.(2007) • Cynthia H. McCollough, PhD, Michael R. Bruesewitz, RT(R), James M. Kofler, Jr, PhD; CT Dose Reduction and Dose Management Tools: Overview of Available Options, RadioGraphics (2006) • M. A. Aweda and R. A. Arogundade; Patient dose reduction methods in computerized tomography procedures: A review, International Journal of Physical Sciences Vol. 2 (1), pp. 001-009, January ( 2007) • Elliot K. Fishman, MD, Cardiac CT:Where are we and where are we going?, www.appliedradiology.com (2006) • Tom H. Mulkens, MD, Patrick Bellinck, MD, Michel Baeyaert, MD, Dirk Ghysen, MD, Xavier Van Dijck, MD, Elvier Mussen, MD, Caroline Venstermans, MD. Jean-Luc Termote, MD; Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi–Detector Row CT Examinations: Clinical Evaluation, Radiology (2006) • Mannudeep K. Kalra, MD, DNB, Stefania Rizzo, MD, Michael M. Maher, MD,, FRCR, FFR (RCSI), Elkan F. Halpern, PhD, Thomas L. Toth, DSc, Jo-Anne O,Shepard, MD, Suzanne L. Aquino, MD; Chest CT Performed with Z-Axis Modulation: Scanning Protocol and Radiation Dose, Radiology ( 2005) • Stefania Rizzo1, Mannudeep Kalra, Bernhard Schmidt, Tejas Dalal, Christoph Suess, Thomas Flohr, Michael Blake, Sanjay Saini; Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CTof the Abdomen and Pelvis, AJR,( 2004) • www.gehealthcare.com

  16. www.redpick.ptformacao@redpick.pt Obrigado

More Related