1 / 31

Medical physics & LPNR

Medical physics & LPNR. Université Mohammed V-Agdal Faculté des Sciences, Rabat. N uclear P hysics L aboratory, R abat (LPNR) , Faculty of Sciences. Created during the sixties of last century Main equipment: Neutron generator, 14 MeV/ SAMES T-400 (1970)

coonm
Download Presentation

Medical physics & LPNR

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Medical physics & LPNR Université Mohammed V-Agdal Faculté des Sciences, Rabat Valencia, 18 -19 november 2010

  2. Nuclear Physics Laboratory, Rabat (LPNR) , Faculty of Sciences • Created during the sixties of last century • Main equipment: • Neutron generator, 14 MeV/ SAMES T-400 (1970) • a, b, g and X spectrometers . Valencia, 18 -19 november 2010

  3. Education at LPNR • Teaching nuclear physics at the undergraduate and graduate courses of university, • Diversification of courses, • Contribution to the development of higher education/ national needs, • Formation through research : • 10 CEA Nuclear Physics, • 1 DESA / Physics and Technology of Radiation • 1 Specialized Master / Medical Physics; • 45 doctorates thesis and • 17 state thesis Valencia, 18 -19 november 2010

  4. Research at LPNR • Main topics (above 40 years) : • Nuclear techniques / applications : • 14 MeV Neutron Activation Analysis, • Cross section measurements (Interaction Nuclear) , • Qualitative or quantitative analysis of samples (industry, geological, biological, archéological …), • Fast neutrons dosimetry, • Natural radioactivity measurements (datation, qualitative / quantitative analyse, ..) Valencia, 18 -19 november 2010

  5. Research at LPNR • Reactor Physics : • Neutron (transport) simulation (anomalies reactors, • High energy physics : • ATLAS collaboration : presampler, test beams, TOP physics • Neutron diffraction analysis :applied to magnetic exchange path in transition elements phosphates • Medical physique: Valencia, 18 -19 november 2010

  6. Medical physics • Why? Request of INO’s radiotherapy department • DESA Radiation Physics and Technology - 2004/2006 • 2 projects DESA 2006 : quality control of radiotherapy treatment apparatus / INO • Professional Master : Medical Physics - 2007/2009 Valencia, 18 -19 november 2010

  7. Medical Physics Professional Master : Medical Physics   • 27 laureates (24 students + professionals medical physicists). • Projects / six months training / hospital : • Radiotherapy departments (19), nuclear medicine departments (7) et radiology department (1) • In Morocco : CHU University hospital centers (Casablanca, Rabat) : 19 projects • Abroad : Argentina: 1, Belgium : 1, Canada: 1 et France: 5  Valencia, 18 -19 november 2010

  8. Professional Master : Medical Physics • Projects of subjects : • Quality assurance • Quality control of treatment or diagnostic apparatus, • Improvement or development of independent programs for dosimetry treatment calculations, • Development and calibration of detection systems (semi-conductor diodes, gafchromiques films, ..), • optimisation of dose patient during medical tests, • Workers radioprotection in a hospital Valencia, 18 -19 november 2010

  9. Validation of a double calculation program with wedge (filtre en coin) [F.Z. Erradi] Wedge Accelerator head Dynamic wedge produced by blade’s movement Wedge moderates isodoses Valencia, 18 -19 november 2010

  10. Validation of a double calculation program with wedge [F.Z. Erradi] • Wedge transmission factor : STT: Segmented Treatment Table, fraction totale du nombre d’unités moniteurs à délivrer en fonction de la position de la mâchoire mobile GSTT: Golden Segmented Treatment Table Y : position de la mâchoire en mouvement θ : angle du filtre en coin Yc : position du centre géométrique du champ ouvert. Ys : position de la mâchoire stationnaire Valencia, 18 -19 november 2010

  11. Validation of a double calculation program with wedge [F.Z. Erradi]  Comparison of wedge transmission factors determined by different methods for X6 energy • EDW factors : measured, ionisation chamber value (same dimension for filtered field or not) for a same monitor unit and a reference depth • Mesureappareil : measured with ionisation chambrer • Calculéclipse: calculated by apparatus code. • Calculmanuel: calculated with theoretical formula Wedge angle Beam dimensions Wedge angle Beam dimensions Valencia, 18 -19 november 2010

  12. Validation of a double calculation program with wedge [F.Z. Erradi] • Validation on water tank • X23 MV energy, 10 cm depth without wedge • X23 MV energy, EDW=15° X et Y : dimension field Valencia, 18 -19 november 2010

  13. Validation of a double calculation program with wedge [F.Z. Erradi] • Validation on patient • Validation performed for the treatment of prostate without wedge Valencia, 18 -19 november 2010

  14. Validation of a double calculation program with wedge [F.Z. Erradi] • Comparative study between independent code and treatment planning system calculations for some medical treatments with wedge Ant : Champs antérieur. Post : Champs postérieur. OAG : Oblique antérieur gauche OPD : Oblique postérieur droit. Lat d : latéral droit. Lat g : latéral gauche Valencia, 18 -19 november 2010

  15. Treatment of hyperthyroidism by iodine 131 [H.Saikouk] • Hyperthyroidism is an increase in thyroid hormones secretion • Aim : Optimizing the dose of iodine administered to patients by applying the simplified method for Marinelli calculating dose M: Thyroid weight F24h: thyroid uptake of iodine after 24 hours Valencia, 18 -19 november 2010

  16. Treatment of hyperthyroidism by iodine 131 [H. Saikouk] • Thyroid mass is determined by ultrasonography. The thyroid is geometrically approximated to two ellipsoids (cm3 ) a: thyroid length b: thyroid width c: thyroid thickness Valencia, 18 -19 november 2010

  17. Traitement de l’hyperthyroïdie par l’iode 131 [H.Saikouk] • Radioprotection • Elaboration d’une fiche informative en langues arabe et française pour les patients traités par I-131 Valencia, 18 -19 november 2010

  18. Treatment of hyperthyroidism by iodine 131 [H. Saikouk] Introduction of two distinctive badges for patients treated with iodine 131 for hyperthyroidism (100 mCi) and those who are in the service for scanning with iodine (3 mCi) • balayage post iratherapieréalisé après 5 joursd’hospitalisation des patients traités pour un cancer de la thyroïde , et inoculation d’uneactivité de 100 mCi, • balayage à l'iode, réalisétrois jour après ingestion d’uneactivité de 3mCi, examen de contrôle après traitementd’unehyperthyroidie. Valencia, 18 -19 november 2010

  19. Currently • Thesis : • 4 radiotherapy (1 brachytherapy) • 2 nuclear medicine • 1 radiology • Subjects : • Quality assurance quality: quality control of treatment or diagnostic apparatus, dosimetry measurements and calculations, medical imaging • Tools : • modelling, simulation, Monte Carlo method, codes (MCNP, Géant4, Gate, EGSnrc code system /BEAMnrc code/DOSXYZnrc/BEAMnrc user codes), experiments Valencia, 18 -19 november 2010

  20. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] Aim : • Monte Carlo simulation of 6MV/18 MV photon beams of INO’s Elekta Precise accelerator • Comparison of measured and calculated dose distributions Experimental measurements • Photon dosimetry performed by diode (PTW 30010) /active volume 0.6 cm³/ 7.1 mm cavity diameter/computer controlled scanning system (OmniPro). • Water tank (Wellhöfer) / 50x50x50 cm³. • Central axis depth-dose and lateral dose profiles / 10x10 cm² field • Uncertainty of measurement less than 2%. Valencia, 18 -19 november 2010

  21. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] Monte Carlo simulation : • BEAMnrc code based on the EGSnrc Monte Carlo system. BEAMnrc  modelling of radiotherapy external beam treatment units  used to build the accelerator • Simulated head model : • target, primary collimator, flattening filter, ion chamber, backscatter plate, mirror, multi-leaf collimator MLC, Jaws in X and Y directions and Mylar screen. • PEGS4 data cross sections of components • the flattening filters different for 6 MV and 18 MV • Accurate data of accelerator provided by Elekta Company, Crawley, United Kingdom. Valencia, 18 -19 november 2010

  22. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] Valencia, 18 -19 november 2010

  23. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] Results 1. Photon spectra • BEAMDP (BEAM Data Processor) used to analyze the phase-space of electron and photon beams generated using BEAMnrc. • Photon spectra calculated with of 0.1 MeV wide bin for 10x10 cm² field. Photon spectral distribution for 6 MV beam : number of photons per MeV per incident electron Valencia, 18 -19 november 2010

  24. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] 2. Depth dose curves and lateral dose profiles • Mean energy : 6 MeV • FWHM of the radial intensity distribution : 1mm. • The gamma index was used for distribution dose comparison with Dmax= 1 % and Zmax= 2 mm. Comparison of the calculated and measured depth dose curves for 6MV photon beam and 10x10 cm². The depth dose curves are normalized to the maximum dose. Valencia, 18 -19 november 2010

  25. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] Comparison of the calculated and measured lateral dose profile for 6MV photon beam /10x10 cm² field. The lateral dose profiles are normalized to the maximum dose. Valencia, 18 -19 november 2010

  26. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] Comparison of average energy of 6 MV and 18 MV photon beams with other works Valencia, 18 -19 november 2010

  27. Monte Carlo calculation of beam quality correction factors of clinical electron dosimetry [H.Nassar] Next steps : • Dosimetric evaluation of the models with a large field on the basis of experimental measurements and calculated dose distribution. • Establishing of a Monte Carlo models for electrons beams • Verification of the electron models with comparing the measured and calculated dose distributions. Valencia, 18 -19 november 2010

  28. Evaluation of some features of the gamma camera using the software GATE [H.Saikouk] • In the previous presentation, Rabat october 2010: • Description of the simulation components • The geometry of SPECThead • The procedure of the validation by an experience in the Nuclear Medicine department of Ibn Sina Hospital in Rabat Valencia, 18 -19 november 2010

  29. Evaluation of some features of the gamma camera using the software GATE [H.Saikouk] Modifications introduced in the simulation • Add aluminium wrap (in red) contouring the crystal  taking into account attenuation of gamma rays in the alumina • dimensions: 59.1x0.36x44.5 cm3 • Add the perspex part to take into account the photomultipliers and the electronics card • Dimensions: 59.1x6x44.5 cm3 Valencia, 18 -19 november 2010

  30. Evaluation of some features of the gamma camera using the software GATE [H.Saikouk] • Adding the real dimensions of the phantom and considering the source to be a point source • Radius : 1.5 cm • Height: 3.9 cm Valencia, 18 -19 november 2010

  31. Evaluation of some features of the gamma camera using the software GATE [H.Saikouk] Preliminary result • The sensitivity: calculated in counts/second/MBq • It’s value: 73 kcounts.s-1.MBq-1 Corresponds to 22.3% Next steps • Measuring the spatial resolution • Validating the simulation by a real experience • Simulating the gamma camera in tomographic mode and validation • Image reconstruction in the gamma camera Valencia, 18 -19 november 2010

More Related