An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. P2 Power Solutions Diesel Generator Primer © P2Power Solutions Pvt. Ltd

  2. Diesel Generator – Working Principle ALTERNATOR DIESEL ENGINE LOAD electrical mechanical chemical © P2Power Solutions Pvt. Ltd

  3. Diesel Generator – Fuel Consumption Pattern efficiency increases with DG size maximum efficiency @ >70% loading © P2Power Solutions Pvt. Ltd

  4. Diesel Generator – Operating Guidelines • Ensure steady load conditions • Minimize load fluctuations • Ensure balanced loading • Minimize load harmonic distortions • Ensure optimum loading (>70%) • Ensure air at generator intake is cold and dust free • Ensure fuel oil storage, handling and preparation as per manufacturers' guidelines • Calibrate fuel injection pumps frequently © P2Power Solutions Pvt. Ltd

  5. Diesel Generator – Load Characteristics Power Factor • Increased current demand • Increased winding losses • Underutilization of capacity: increased capital expenditure, lower efficiency. Load unbalance • Unbalanced output voltages • Heating in alternator windings • Underutilization of capacity Non Linear loads • Overstressing of generators • Distorted voltage profile • Heating in alternator windings • Underutilization of capacity © P2Power Solutions Pvt. Ltd

  6. Case Study I Power Factor Improvement on DG DG Specifications: 3 phase, 415V, 50Hz, 500kVA. Operation: 6000 hours/yr © P2Power Solutions Pvt. Ltd

  7. Case Study II Parallel Operation of DG sets © P2Power Solutions Pvt. Ltd

  8. PF Correction – Benefits KW loading should be within limits at all times © P2Power Solutions Pvt. Ltd

  9. PF Correction – Capability Curve Red: Critical Zone © P2Power Solutions Pvt. Ltd

  10. PF Correction – Traditional Solutions Potentially damage D.G © P2Power Solutions Pvt. Ltd

  11. Active Power Conditioner – Technology © P2Power Solutions Pvt. Ltd

  12. Active Power Conditioner – Technology D.G active Load reactive + harmonic APC © P2Power Solutions Pvt. Ltd

  13. Active Power Conditioner – Technology © P2Power Solutions Pvt. Ltd

  14. © P2Power Solutions Pvt. Ltd

  15. Thanks! © P2Power Solutions Pvt. Ltd