1 / 26

HCV window phase infections: Closing the window on HCV

HCV window phase infections: Closing the window on HCV. Philip William Tuke. A comparison of two combined Ag / Ab assays with QRT-PCR. Closing the window on HCV. HCV alone comprises the Hepacivirus genus, a member of the Flavivirus family SS +ve RNA virus in a protein core

clark
Download Presentation

HCV window phase infections: Closing the window on HCV

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HCV window phase infections:Closing the window on HCV Philip William Tuke A comparison of two combined Ag / Ab assays with QRT-PCR

  2. Closing the window on HCV • HCV alone comprises the Hepacivirus genus, a member of the Flavivirus family • SS +ve RNA virus in a protein core • Important human pathogen infecting ~3% of the world population1 • >5 million people infected in Europe2 • Prevalence of HCV infection in UK 0.4% England3 1.0% Scotland4 • Blood donor seropositivity .041% new donors, .0016% repeat donors5

  3. Closing the window on HCV

  4. Closing the window on HCV • HCV potential major cause of post transfusion hepatitis • Incidence initially dramatically reduced by Ab screening • Subsequently further reduced by NAT • Window period = time to detection • Ab window 51 days

  5. Closing the window on HCV • NAT and / or Ag testing can be undertaken to close this window • Testing of donations by NAT may not be feasible or economic

  6. Closing the window on HCV Samples • Plasma from HCV viraemic Ab neg “window phase” donors • Panel 1: 40 HCV NAT positive plasma samples from 17 US donors (11) • Panel 2: 94 plasma samples from US donors • Panel 3: 8 /10 NAT positive plasmas from 12,000,000 UK blood donors ’99-’03

  7. Closing the window on HCV RT-PCR • HCV detected by LightCycler (NTMRL) or quantified by TaqMan (UCLH) • Genotyped by sequencing 5’ ncr and in-silico determination of RFLP sites and line probe binding sites

  8. Closing the window on HCV Serology • Samples confirmed Ab neg by Ortho-HCV v 3.0 • Bio-Rad and Murex combined Ag-Ab assays performed per manufacturer’s instructions • NOD = OD/cut off (NOD ≥ 1 +ve except BioRad for Panel 3 where modified criterion of 0.5 used)

  9. Closing the window on HCV • Results • 142 plasmas 112 (79%) HCV RNA + ve • Wide range of viral loads (14 - 64,800,000 IU/ml) • 36 detected by Bio-Rad (32%) • 56 detected by Murex (50%) • 45 plasmas with viral load > 1,000,000 IU/ml • Bio-Rad 35 +ve (78%) • Murex 44+ve (98%)

  10. Closing the window on HCV • Detection limits interpolatedfrom Panel 1 • Murex 200,000 IU/ml • BioRad 4,000,000 IU/ml • Bio-Rad failed to detect all genotype 3a in Panels 1 & 2 although 2 donations viraemia >4,000,000 IU/ml

  11. Closing the window on HCV

  12. Closing the window on HCV

  13. Closing the window on HCV Distribution of viral loads Panel 2

  14. Closing the window on HCV • Viral loads similar in all 3 panels • No stat sig diffs. • 2 US Panels1 and 2, regarded as single pop • Viral loads of genotypes • (1a, 1b, 2 and 3a) in this US pop similar, • no sig diff between them (Figure 2).

  15. Closing the window on HCV

  16. Closing the window on HCV

  17. Closing the window on HCV • Greater sensitivity of Murex for each genotype (Figure 2) • Murex detected ~50% of genotypes 1a, 1b and 2 but 27% of genotype 3a • Bio-Rad detected ~40% of 1b and 2, 33% of 1a; failed to detect ANY genotype 3a • Failure to detect 3a indicated Abs used for Ag detection may have a genotypic bias

  18. Closing the window on HCV • UK 10 NAT window phase in 14,000,000 Ab neg • donations 1999-2003, total cost £60 million • Panel 3 = 8 available for serological testing • Bio-Rad detected 5/8 62.5% (NOD 0.5 +ve) • Murex detected 6/8 75% • Very high % of 3a 6/8 (75%) • UK prevalence data genotype 3a:- 37% 199921 • UK HCV National Register N=749 29% 200622 • Our departmental data similar 29.4%

  19. Closing the window on HCV • Prevalence 3a in IDUs 54% 23 and 43% 24 • 7 of the 10 UK NAT only +ves = genotype 3a , • 3 reported risk factor, 2 = IDU / partner of IDU • Possible majority of HCV window phase in blood donors 1999-2003 covertly linked to IDU • Since 2003 NAT only detection rate 0 in >6 million • European study of NAT testing within transfusion • setting critical of the financial benefits 9

  20. Closing the window on HCV • Cost benefit analysis not only consideration • Political implications of change from “best • practice” to more economic alternative needs • careful consideration • May be time to resist stampede towards “Gold • Standard” of NAT ultimate sensitivity • Perhaps window closing not just on HCV • infections but on NAT testing and a new era of • combined Ag Ab assays lies ahead

  21. Closing the window on HCV • Conclusions • Combined Ag Ab assays provide a useful improvement • on sole reliance on Ab testing • However, they remain less sensitive than PCR for • detecting viraemic donors • Combined assays may be genotype susceptible • Now is the time to consider combined assays as a • viable alternative to NAT testing

  22. Closing the window on HCV Acknowledgements: This work was funded by the NBS Organised jointly by Dr Roger Eglin Prof Richard Tedder The work at UCLH was performed by: Dr Philip W Tuke Dr Paul R Grant James Waite All testing at NTMRL NBS Colindale was supervised by Dr Alan Kitchen US samples were provided by Dr Cate Sims BPL

  23. Closing the window on HCV 1. World Health Organization. World Health Organization, Weekly Epidemiological Record 1997: 72: 65-72. 2. Trepo C, Pradat P. Hepatitis C virus infection in Western Europe. Journal of Hepatology 1999;80-3. 3. Department of Health. Hepatitis C. Action plan for England. Department of Health Report No.: 40180 . 2004. 4. Hutchinson SJ, Roy KM, Wadd S, Bird SM, Taylor A, Anderson E, Shaw L, Codere G, Goldberg DJ. Hepatitis C virus infection in Scotland: Epidemiological review and public health challenges. Scottish Medical Journal 2006;8-15. 5. Soldan K, Davison K, Dow B. Estimates of the frequency of HBV,HCV and HIV infectious donations entering the blood supply in the United Kingdom, 1996 to 2003. Eurosurveillance 10 (2) (2005) 17-19. 2005. 9. Pillonel J, Laperche S. Trends in risk of transfusion-transmitted viral infections (HIV, HCV, HBV) in France between 1992 and 2003 and impact of nucleic acid testing (NAT). Euro.Surveill 2005;5-8. 21.Harris KA, Gilham C, Mortimer PP, Teo CG. The most prevalent hepatitis C virus genotypes in England and Wales are 3a and 1a. Journal of Medical Virology 1999;127-31. 22.Harris HE, Eldridge KP, Harbour S, Alexander G, Teo CG, Ramsay ME. Does the clinical outcome of hepatitis C infection vary with the infecting hepatitis C virus type? J.Viral Hepat. 2007;213-20. 23.Buckton AJ, Ngui SL, Arnold C, Boast K, Kovacs J, Klapper PE, Patel B, Lbrahim I, Rangarajan S, Ramsay ME, Teo CG. Multitypic hepatitis C virus infection identified by real-time nucleotide sequencing of minority genotypes. Journal of Clinical Microbiology 2006;2779-84. 24.Mohsen AH. The epidemiology of hepatitis C in a UK health regional population of 5.12 million. Gut 2001;707-13.

  24. Closing the window on HCV Genotype viral load regression lines

  25. Closing the window on HCV Table 1 Panel 2 results UCLH Table 1 summarises characeristics of the various genotypes of samples which form Panel 2 in terms of the results obtained at UCLH for viral load and combined antigen antibody tests.

  26. Closing the window on HCV Table 2 Comparison of results for Panels 1, 2 and 3 Table 2 summarises characeristics of the three panels of samples in terms of viral loads and combined antigen antibody test reults. The data from the samples in panel 1 have been presented in three forms; * as a group of the total 40 plasmas, †as the results for individual donors where one positive plasma results in the donor being regarded as positive for that test, and ‡ as the result of the first sample tested on each of the 17 donors.

More Related