slide1
Download
Skip this Video
Download Presentation
MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway!

Loading in 2 Seconds...

play fullscreen
1 / 21

MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway! - PowerPoint PPT Presentation


  • 92 Views
  • Uploaded on

MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway!. www.corinex.com. Corinex Enterprise Products Powerline Networking (Common Power Meter) Powerline Networking (Individual Power Meters) Coaxial Networking Coax and Powerline Networking (Common Power Meter).

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' MDU Networking using CORINEX products including the new 600 Mbps Corinex MDU Gateway!' - ciro


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

MDU Networking using CORINEX productsincluding the new 600 Mbps Corinex MDU Gateway!

www.corinex.com

slide2
Corinex Enterprise Products
  • Powerline Networking (Common Power Meter)
  • Powerline Networking (Individual Power Meters)
  • Coaxial Networking
  • Coax and Powerline Networking (Common Power Meter)
mdu networking product family
MDU Networking – Product family
  • MDU Gateway creates a Powerline or Coaxial backbone
  • AV200 Enterprise Powerline
  • Ethernet Adapter CPE
  • AV200 Enterprise Powerline
  • Wall Mount CPE
  • AV200 Enterprise CableLAN CPE
  • 5+1 and 11+1 Phase Coupler (for bypassing Individual Meters)
  • Corinex High Pass and Mode Filters
  • Installation Training to teach hardware and software configuration

CorinexAV200

Enterprise Powerline

Ethernet Adapter

CorinexAV200

Enterprise Powerline

Wall Mount

Corinex 5+1

Phase Coupler

Corinex 11+1

Phase Coupler

Powerline networking components

CorinexMDU Gateway

Powerline and Coax

Corinex

Installation

Training

CorinexAV200

Enterprise

CableLAN Adapter

Corinex High

Pass Filter

Corinex Mode

Filters

Coaxial networking components

mdu gateway features

Corinex MDU Gateway

MDU Gateway - Features
  • 3 AV200 200 Mbps Powerline Modules
    • 3 * 200 Mbps = 600 Mbps
  • Coaxial or Powerline input/outputs
  • Modules act as a Master / Head End
  • 2-34 MHz operation, 2-30MHz in EU (mode 6)
  • Optional Frequency Band segmenting using:
    • 2-12 MHz (mode 1)
    • 13-23 MHz (mode 2)
    • 24-34 MHz (mode 3)
  • Optional Built in Filters to support Frequency Band segmenting
  • Up to 32 users (CPE) per Module / 96 users per MDU Gateway (Coax or Common Power Meter in building)

OR

  • Up to 11 electrical meters connected per Module / 33 per MDU Gateway (Individual Power Meters in building)
  • World’s ONLY enterprise MDU product!
  • World’s ONLY 600 Mbps product!
mdu gateway back panel and interfaces
MDU Gateway – Back Panel and Interfaces
  • Each Module has Coaxial and Powerline Input/Outputs
  • Within a single MDU Gateway a mix of Coax and Powerline input/outputs between modules is allowed
  • Example:
      • Module 1: Coax
      • Module 2: Powerline
      • Module 3: Powerline
      • or
      • Module 1: Coax
      • Module 2: Coax
      • Module 3: Powerline
      • or …
  • DO NOT use both Coax AND Powerline outputs on same module-interface

Module 1

Powerline

Input/Output

Module 2

Powerline

Input/Output

Module 3

Powerline

Input/Output

Power On/OFF

Module 1

Coax

Input/Output

Module 2

Coax

Input/Output

Module 3

Coax

Input/Output

Power

Connection

10/100 BaseT

slide6
Corinex Enterprise Products
  • Powerline Networking (Common Power Meter)
  • Powerline Networking (Individual Power Meters)
  • Coaxial Networking
  • Coax and Powerline Networking (Common Power Meter)
slide7

M.Power

Distrib.

Panel

Powerline Networking (Common Power Meter)

Electrical

Dist. Panel

  • Scenario 1:
  • (Hotels, Barracks, Residential)
  • 1 electrical phase per 2 floors
  • First 6 floors served by one transformer
  • Additional floors served by other transformer(s)
  • Same scenario for each phase serving different number of floors

6th Floor

5th Floor

Phase 3

4th Floor

3rd Floor

Phase 2

2nd Floor

Phase 1

Pre Deployment Situation

1st Floor

Main Power Meter

slide8

Optical Fiber

(or other broadband)

Power

Distribution

Panel

Power

Distrib.

Panel

Powerline Networking (Common Power Meter)

BROADBAND SIGNAL

INJECTED IN POWERLINES

Electrical

Dist. Panel

  • Scenario 1:
  • Pure Powerline Networking:
  • Powerline Backbone (bypass meter)
  • Powerline within floor
  • 1 module for each of 3 phases
  • Direct Connection (no coupler)
  • AV200 Powerline CPE in each apartment/flat served
  • Up to 32 users per phase
  • 3 frequency bands (Mode 1,2,3
  • for the 3 modules)

Mode 1

Phase 3

6th Floor

MDU Gateway

Module 1 = Mode 1

Module 2 = Mode 2

Module 3 = Mode 3

Mode 1

5th Floor

Mode 2

Phase 2

4th Floor

Plug MDU Gateway into each

electrical phase at 3 wall

outlets of distribution panel

Mode 2

3rd Floor

Mode 3

Phase 1

2nd Floor

Mode 3

1st Floor

TIP: Mode 1 propagates furthest,

then Mode 2, then Mode 3

MDU Gateway

Main Power Meter

Post Deployment Situation

slide9
Corinex Enterprise Products
  • Powerline Networking (Common Power Meter)
  • Powerline Networking (Individual Power Meters)
  • Coaxial Networking
  • Coax and Powerline Networking (Common Power Meter)
powerline networking individual power meters
Powerline Networking (Individual Power Meters)
  • Scenario 2:
  • Residential Apartments/Flats:
  • Power Meters attenuate
  • Powerline signals by 5 to 45dB
  • MDU Gateway
  • Powerline Backbone
  • 5+1 / 11+1 Electrical
  • phase coupler
  • AV200 Powerline CPE In-Home
  • Full Frequency band (mode 6)

Pre Deployment Situation

slide11

Powerline Networking (Individual Power Meters)

Corinex MDU Gateway

Each Module-interface

gives a 200 Mbps

connection

Ethernet 10/100 Base-T

Module

1

Mode 6

Module

2

Mode 6

Module

3

Mode 6

Electrical

Wire

Electrical

Wire

Electrical

Wire

Use either 5+1 or 11+1 Phase

Coupler on each module to

connect up to 11 electrical

meters per module-interface

Corinex 11+1

Phase Coupler

Corinex 5+1

Phase Coupler

Corinex 11+1

Phase Coupler

IN

OUT

IN

OUT

IN

OUT

Meter

Meter

Meter

Meter

Meter

Meter

Meter

Meter

Meter

To individual Apartments

/ Flats with AV200

Powerline CPE for

In-Home connectivity

From Utility Power Feed

Meter

Meter

Meter

Up to 11

Power Meters

Up to 11

Power Meters

Up to 11

Power Meters

Post Deployment Situation

slide12
Corinex Enterprise Products
  • Powerline Networking (Common Power Meter)
  • Powerline Networking (Individual Power Meters)
  • Coaxial Networking
  • Coax and Powerline Networking (Common Power Meter)
slide13

Coaxial Networking

Continue to

the next floor

Apart 32

  • Scenario 3:
  • (Hotels, Residential, Barracks)
  • 1 coax panel per floor
  • Additional floors on same coax line
  • ≤ 32 users per floor

Apart 3

Apart 2

Apart 1

Apart 32

Apart 3

Apart 2

Apart 1

Coax

Dist. Panel

Apart 32

Apart 3

Apart 2

Apart 1

Main

Cable

Pre Deployment Situation

Splitter

slide14

Broadband Source

Coaxial Networking

Continue to

the next floor

  • Scenario 3:
  • Pure Coax Networking:
  • Coax Backbone
  • All 3 Modules inject signal
  • Coax within floor
  • 1 Module (up to 32 users)
  • per Coax distribution panel
  • AV200 CableLAN CPE In-Home
  • 3 frequency bands (modes 1,2,3)
  • Add more segments to expand (add High Pass Filter and another MDU Gateway on 4th Floor connected via Ethernet)

Mode 3

Apart 32

Apart 3

Apart 2

Apart 1

Corinex Mode

3 Filter

Mode 1

Mode 2

Mode 3

Mode 2

Apart 32

Apart 3

Apart 2

Apart 1

Corinex Mode

2 Filter

Mode 1

Mode 2

Mode 3

Coax

Dist. Panel

COAX BACKBONE

Mode 1

Apart 32

Apart 3

Apart 2

Apart 1

Corinex Mode

1 Filter

Mode 1

Mode 2

Mode 3

MDU Gateway

Module 1 = Mode 1

Module 2 = Mode 2

Module 3 = Mode 3

3 way

Splitter

Splitter

Main

Cable

Post Deployment Situation

slide15

Broadband Source

Coaxial Networking – Creating the Coaxial Backbone

Continue to

the next floor

Coax

Dist. Panel

Coaxial Backbone

Injection Unit Options

Mode 6

COAX BACKBONE

OPTION 2:

Corinex AV200

Enterprise CableLAN

OPTION 1:

Corinex Head End

Mode 6

Main

Cable

Splitter

OPTION 3:

MDU Gateway

Mode 6

OPTION 3:

MDU Gateway

slide16

Coaxial Networking

Continue to

the next floor

Apart 32

  • Scenario 4:
  • (Hotels, Residential, Barracks)
  • 1 coax panel per floor
  • Additional floors on same coax line
  • > 32 users per floor

Apart 3

Apart 2

Apart 1

Apart 32

Apart 3

Apart 2

Apart 1

Coax

Dist. Panel

Apart 32

Apart 3

Apart 2

Apart 1

Main

Cable

Splitter

Pre Deployment Situation

slide17

Apart 64

Apart 64

Apart 64

Apart 4

Apart 4

Apart 4

Apart 3

Apart 3

Apart 3

Apart 2

Apart 2

Apart 2

Apart 1

Apart 1

Apart 1

Coaxial Networking

Continue to

the next floor

  • Scenario 4:
  • MDU Networking Solution
  • Coax Backbone
  • 1 Module to carry input
  • Coax within floor
  • 1-2 Modules for each coax distribution panel (up to
  • 64 users)
  • AV200 CableLAN CPE In-Home
  • Full Frequency band on
  • Backbone (mode 6),
  • Full Frequency band on floor
  • (≤ 32 users) or Partial
  • frequency band on floor
  • (> 32 users, mode 1/2)

Mode 6 or Mode 1/2

Mode 6

Coaxial

Distribution

Panel

Mode 6

Mode 6 or Mode 1/2

COAX BACKBONE

Coaxial

Distribution

Panel

Mode 6

MDU Gateway

Mode 6 or Mode 1/2

Splitter

Coaxial

Distribution

Panel

Coax

Backbone

Post Deployment Situation

Corinex High

Pass Filter

Splitter

Splitter

slide18
Corinex Enterprise Products
  • Powerline Networking (Common Power Meter)
  • Powerline Networking (Individual Power Meters)
  • Coaxial Networking
  • Coax and Powerline Networking (Common Power Meter)
coax and powerline networking common power meter

Apart 32

Apart 32

Apart 32

Apart 4

Apart 4

Apart 4

Apart 3

Apart 3

Apart 3

Apart 2

Apart 2

Apart 2

Apart 1

Apart 1

Apart 1

Coax and Powerline Networking (Common Power Meter)

Continue to

the next floor

  • Scenario 5:
  • Coaxial / Powerline Hybrid
  • Coax Backbone
  • 1 Input Module
  • Powerline within floor
  • 1 Module for each electrical panel = 32 users per panel
  • Direct Coupling to Power – No Electrician Required
  • AV200 Powerline CPE In-Home
  • Full Frequency band (mode 6) on backbone and floor

Plug directly (any

Electrical Phase)

Electrical

Subpanel

Mode 6

Mode 6

Plug directly (any

Electrical Phase)

Electrical

Subpanel

Mode 6

COAX BACKBONE

Mode 6

Plug directly (any

Electrical Phase)

Electrical

Subpanel

Mode 6

MDU Gateway

Coax

Backbone

Post Deployment Situation

Splitter

coax and powerline networking common power meter1

Apart 64

Apart 64

Apart 4

Apart 4

Apart 3

Apart 3

Apart 2

Apart 2

Apart 1

Apart 1

Coax and Powerline Networking (Common Power Meter)
  • Scenario 6:
  • Coaxial/Powerline Hybrid
  • Coax Backbone
  • 1 Input Module
  • Powerline within floor
  • 2 Modules for each electrical panel = 64 users per panel
  • Direct Coupling to Power – No Electrician Required
  • AV200 Powerline CPE In-Home
  • Full Frequency band on Backbone (mode 6), Segmented Frequency band on floors (modes 1,2,3)

Continue to

the next floor

Apart 64

Mode 3

Electrical

Subpanel

Apart 4

Apart 3

Mode 2

Apart 2

Apart 1

Mode 1

Electrical

Subpanel

Mode 6

Mode 3

Mode 2

Mode 6

Electrical

Subpanel

COAX BACKBONE

Mode 1

Post Deployment Situation

MDU Gateway

Coax

Backbone

Splitter

slide21

MDU Networking – Summary

  • Corinex MDU Networking Products:
    • Allow you to network an entire building regardless of size or shape or metering
    • Allow you to network an entire building without adding any additional wiring
    • Offer the highest performance MDU Networking available
  • Corinex increases buildings property owners investment value
  • Corinex MDU solution guarantees you very quick ROI and investment protection as the broadband network becomes part of your intelligent building property.
  • Corinex MDU Gateway is the only product of its kind in the industry – 600Mbps!
  • MDU Broadband equipment revenues will triple in the next 4 years – The Corinex MDU Gateway allows you to win your share!
ad