1 / 13

Recent Antiproton Lifetimes in the Recycler Ring

Recent Antiproton Lifetimes in the Recycler Ring. All Experimenters Meeting November 16 th , 2009 L. Prost for the Main Injector Dpt. Coming out of the Summer shutdown….

chase
Download Presentation

Recent Antiproton Lifetimes in the Recycler Ring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recent Antiproton Lifetimes in the Recycler Ring All Experimenters Meeting November 16th, 2009 L. Prost for the Main Injector Dpt.

  2. Coming out of the Summer shutdown… • Expected some lifetime degradation (w.r.t. pre-shutdown) because of poorer vacuum in the two regions (401-409 & 103-109) that were vented up • Good recovery overall but larger N2 partial pressure RGA scans at 401-409(IPs ON, TSPs sublimated) After Before 10-10 Torr full scale H2(out of scale) H2(out of scale) N2 Note: There was ~one month of pumping time before seeing protons (for this region only)

  3. Evolution of symptoms • First check out of the Recycler showed good lifetime • Although was never back to pre-shutdown typical values • Recycler performance appeared to have continuously degraded since early October • Lifetime startedto get poor atall intensities(next slide) • High averageemittanceswhile stashing • Poor extractionefficiency Average Schottky emittance, 95% n Electron beam position, mm Pbar intensity, E10

  4. Lifetime (as measured) vs Time • Lifetime is worse by a factor of ~2 for comparable conditions • We were losing an extra ~5% of pbars in the Recycler 10-min average lifetime, hrs # of pbars, E10 ~1 month

  5. Possible reasons and checks • Large emittances from Accumulator ? • Unlikely because the lifetime does not improve toward a steady state, when the ‘memory’ about the transfers should disappear • Worse electron cooling ? • Measurements indicate that it cools better than ever • Actually, worse cooling efficiency would likely improve lifetime • Heating by stochastic cooling system ? • Checked and adjusted parameters • Turning some systems off does not improve the lifetime • Cannot explain a higher diffusion rate • Diffusion rate obtained while measuring the electron cooling rate • Dampers ? • Phasing was checked • On or Off does not make any difference

  6. Possible reasons and checks (cont.) • Vacuum ? • No clear indications from ion gauges (or ion pumps) • Should be a constant offset in rates at all intensities • Storing of ions ? • Would be the most consistent explanation • All clearing PS are shown to be working and were checked; connections were visually checked during the final tour of the tunnel • Changes in the lattice ? • Was measured • Changes are at the ~10% level at max. • Too small a change for our large acceptance (which was also checked)

  7. Emittance growth rate measurement Vertical emittance (fast monitor) Horizontal emittance (fast monitor) Vertical emittance (slow monitor) Expected rate(~0.8 p mm mrad) Horizontal emittance (slow monitor) • Almost all systems are turned off (electron beam, dampers, RF, stochastic cooling) and the beam is let diffuse • Path length compensation (MI ramping) was kept on • Best way to indicate a problem with vacuum • Transverse emittance growth rate is 4-6 times higher than normal • Need totake acloserlook atvacuum

  8. Vacuum history at 313 (since early April) • Even though the magnitude of the vacuum degradation cannot explain the emittance growth measurement, we decided to sublimate the TSPs in this region (308-319) • Leak checking is noteasy in the Recycler • Also applied vacseal to an ionpump connector(ceramic part) Shutdown Ion pump (Torr) Ion gauge (Torr) TSPs sublimated on Nov 4

  9. Current Status (I) • Although the vacuum did not return to the pre-shutdown level, the lifetime greatly improved • Likely to itspre-shutdowntypical values • There is still thepossibility of asmall leak in thearea(313 pressurecontinues to rise very slowly) Before vacuum work After vacuum work 10-min average lifetime, hrs Pelletron repair # of pbars, E10

  10. Emittance growth rate check Dotted line: rates before vacuum work Vertical emittance (fast monitor)p mm mrad Horizontal emittance (fast monitor)p mm mrad Vertical emittance (slow monitor) p mm mrad Horizontal emittance (slow monitor) p mm mrad Reduced by a factor ~2

  11. Summary • Average antiproton lifetime decreased continuously since coming out of the Summer Shutdown • Only vacuum degradation seemed to be a possible explanation (around sector 313 in particular) • Lifetime in the Recycler greatly improved after sublimating TSPs in the 308-319 region • Will request sublimating more TSPs around the ring over the next few weeks • Many TSPs have not been sublimated in more than 4 years and may be saturated (i.e. slow to no pumping)

  12. EXTRAS

  13. Life time comparison under “steady-state” The life time was found to correlate only with the linear density of the pbar beam. Sep-Oct points were collected slightly differently. Sep-09 points are lower than Dec08, and Oct-09 point is much lower. Part of this can be attributed to a worse vacuum. 13 No transfers (for more than 1.5 hours) No changes of e-beam position No changes in the pbar beam length or structure Emittances close to an equilibrium at the end of the period, where all parameters are recorded

More Related