Trane Variable Water Flow System. Outdoor Air-cooled Water Chiller. Installation, Operation & Maintenance. Trane Variable Water Flow System. Introduction What is VRF system? System Profile System & Components Chiller Unit Nameplate. Trane Variable Water Flow System. What Is It?.

Download Presentation

Trane Variable Water Flow System

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Trane variable water flow system

Trane Variable Water Flow System

Outdoor Air-cooled Water Chiller

Installation, Operation & Maintenance


Trane variable water flow system1

Trane Variable Water Flow System

  • Introduction

    • What is VRF system?

  • System Profile

    • System & Components

  • Chiller Unit

    • Nameplate


Trane variable water flow system

Trane Variable Water Flow System

What Is It?

Digital Chiller

Trane Variable Water Flow System

Cassette

High Wall

Concealed

Concealed

RS485

Central Controller

Thermostat

Thermostat

Remote Controller

Remote Controller

Inflow Water loop

Outflow Water loop

Communication line

3

  • A newlydesigned,digitally controlled air-cooled variablewater chiller system

    • Variable Refrigerant Flow in Refrigeration Loop & Variable Water Flow in water loop

    • Water used as heat transfer media, no refrigerant in occupied space


Trane variable water flow system

Outdoor Unit

  • Digital Scroll Compressor

  • Built-in two-speed water pump

  • Fan design delivers reduced noise levels

Cooling capacity range

6RT

8RT

10RT

12RT

14RT

  • CGD*100/ 120/ 150/ 175/ 200

  • Cooling: 24.5kW - 48.5kW

  • Heating: 24.5kW - 48.5kW

  • Power source: 220V/60Hz/3Ph

    • 380V/50Hz/3Ph


Trane variable water flow system

Outdoor Unit

10RT

12RT \ 14RT

6RT \ 8RT

Digital

Fixed

Digital

Fixed

Digital

Fixed

Fixed

Cabinet Size (mm) (HxWxD): 1,900 x 1,290 x 600

Cabinet Size (mm) (HxWxD): 1,900 x 1,990 x 600

Cabinet Size (mm) (HxWxD): 1,900 x 1,990 x 600


Trane variable water flow system

Digital Scroll Compressor

  • Pulse Width Modulation (PWM signal)

  • 10-100%continuous capacity control

  • Superior performance

  • Simplified control parts


Trane variable water flow system

System Controllers

Type

Central Controller

(Standard)

Controllers

Unit Controllers

Type of ID

Wired

Remote

Concealed

NotAvailable

Cassette

  • Central controller is a “must have”

  • Wired thermostat is Trane Patented design

    • Color back light

    • Last setting for resuming power

Hi-Wall

Notavailable


Trane variable water flow system

Controllers

Wired Controller

Remote Controller

Central Controller

  • Remote ON/OFF fan coil

  • Function setting, temperature regulation, air velocity setting

  • Sleep mode setting, timer setting function

  • Remote control distance ≥5M

  • Patented design

  • LCD display

  • Cooling/heating/ ventilation control

  • Sleeping mode

  • Last setting for resuming power

  • Multi-zone control

  • Individual zone control

  • Troubleshooting

  • Timer setting

  • Mode setting


Trane variable water flow system

How to Select “EarthWise”

OD Parameter Setting:

Set leaving water temp to 5°C

via central controller

  • In-Door Unit Selection:

  • Concealed unit: select “Earthwise” application

  • High wall & Cassette: Not available

  • Digit 17: Application

  • N = Normal application

  • E = Earthwise

Choose “Earthwise” option in TDS tools to run product configuration report


Model number description

Model Number Description

C G D K 1 0 0 2 H E A Z R N R R A C

1 2 3 4 5,6,7 8 9 10 11 12 13 14 15 16 17 18

Digit 1,2,3 — Unit Type

CGD= Digital Air-Cooled Water Chiller Refrigeration Circuit

Digit 4 R = Heat Pump K = Cooling Only

Digit 5-7 — Nominal Capacity (Tons) 100 = 6 120 = 8 150 = 10 175 = 12 200 = 14

Digit 8 — Voltage Selection 2 = 220V/60 Hz/3 ph 5 = 380V/50 Hz/3 ph

Digit 9— Airflow Configuration H = Horizontal

Digit 10— Refrigerant E = R-22

Digit 11 — Manufacturing Code (defaulted by factory) A = Double Compressors B = Triple Compressors

Digit 12 — Central Controller Z = With Central Controller (as standard)

Digit 13 — Chilled Water Pump R = Water Pump

Digit 14 — Auxiliary Electric Heater in Water Circuit N = None

Digit 15 — Ambient Temperature R = Standard Ambient Temperature Set (Standard)

Digit 16 — Water Pipe Direction (Face to the Airflow) R = Right Side (Standard) B = Back Side (Optional)

Digit 17 — Design Sequence (Not for client) A = First Version B = Second Version

Digit 18 — Region V = China A = APR B = MAIR C = LAR


Trane variable water flow system

PVC Pipe Installation Benefits

  • PVC pipe and fitting price is 4 times cheaper than steel pipe’s.

  • PVC Pipe weight is 6 times less than steel pipe’s.

  • Use smaller pipe size because friction loss of PVC pipe is much less than steel pipe’s.

  • Easy transportation, Easier and quicker installation, longevity


Trane variable water flow system

PVC Pipe Installation Benefits


Trane variable water flow system

PVC Pipe Installation Benefits

*The percentage price difference is based on the price in Thailand.