Gas Plenum in XT-ADS Fuel Rod. V. Sobolev, B. Arien SCK·CEN, Boeretang 200, Mol, Belgium. Introduction. During the DM1 Meeting in MOL it was required to adapt the gas plenum of XT-ADS fuel rod to assure the cladding withstand during 30 minutes at ULOF conditions at 100 % FG release.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Gas Plenum in XT-ADS Fuel Rod' - charles-lang


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Gas plenum in xt ads fuel rod

Gas Plenum in XT-ADS Fuel Rod

V. Sobolev, B. Arien

SCK·CEN, Boeretang 200, Mol, Belgium


Introduction
Introduction

  • During the DM1 Meeting in MOL it was required to adapt the gas plenum of XT-ADS fuel rod to assure the cladding withstand during 30 minutes at ULOF conditions at 100 % FG release.

  • The recommended values for acceptable cladding temperatures and pressures were presented at the same meeting by D. Struwe and W. Pfrang (see next slide).


Introduction1
Introduction

Best estimate values from the CIEMAT creep experiment with T91 steel (D. Struwe, W. Pfrang, Mol, 20-21 June 2006)

Gas plenum pressure 5 MPa 10 MPa

Clad failure time Mid-wall clad temperature

10 000 h 955 K 920 K

1 000 h 985 K 955 K

10 h 1065 K 1030 K

1 h 1115 K 1070 K

30 min 1125 K 1080 K

2 min 1180 K 1135 K


2 xt ads fuel pin schematics pre design of june 2006

Upper reflector-insulator

OD=5.40

ID=1.50

Lower reflector-insulator

OD=5.40

ID=1.50

Support

Spring chamber

Fuel pellet OD=5.40 ID=1.60

Cladding OD=6.55 ID=5.60

Gas plenum

Spring

Bottom-cap

Top-cap

6.55

20

60

100

20

600

300 (?)

100

1200 (?)

2. XT-ADS fuel pin schematics (pre-design of June 2006)


2 xt ads fuel pin equivalent gas chart
2. XT-ADS fuel pin: Equivalent gas chart

Filling gas:

Hot stand-by:


3 pressure within fuel pin
3. Pressure within fuel pin

Operation at nominal power:

In LMFBR:

- released fraction of the i-th gas


4 operation conditions
4. Operation conditions

  • Hottest fuel column: <ql> = 201 W/cm, Kaxial hot = 1.257

  • Filling gas pressure: 0.2 MPa (He at STP)

  • Coolant:

    • Tinlet = 603.15 K (330 °C)

    • Nominal operation: DTcore = 90 K x Kcore rad =

      = 90 K x 1.375 = 123.75 K (°C)

    • ULOF: DT=472.25 K (°C) determined by natural convection (DHcore-HX = 2 m; 60 % core resistance).


5 temperature field in the hottest pin
5. Temperature field in the hottest pin

Nominal operation at BOL (FEMAXI-5.1- mod.SCK; EFR TC )


5 temperature field in the hottest pin1
5. Temperature field in the hottest pin

ULOF at BOL (FEMAXI-5.1- mod.SCK)


6 free volumes and pressure within xt ads pin
6. Free volumes and pressure within XT-ADS pin

Pressure and free volumes (cm³) within the main segments of the hottest fuel rod

The max. clad temperature at ULOF is 1117 K (844 °C) without clad corrosion, and the allowed pressure (Table on Slide 3, D. Struwe) is lower than 7.5 MPa.

Clad corrosion will create more severe situation (see next slide).




8 updated xt ads rod design proposal1
8. Updated XT-ADS rod design (proposal)

It has been postulated that the maximum thickness of the corrosion layer is 10 % of the initial clad thickness, i.e. 47.5 microns


Conclusions
Conclusions

  • In order to assure the 30-minute cladding resistance of the hottest XT-ADS fuel rod under ULOF conditions, the gas plenum should be increased.

  • Clad corrosion can play a critical role. Taking into account a large uncertainly in the cladding corrosion, it is proposed to postulate at this stage of design that corrosion is limited to 10 % of the clad thickness.

  • The updated pin design with a larger gas plenum (580 mm) is proposed as a possible solution.



Unprotected lof
Unprotected LOF

  • core inlet T: 330°C

  • DH core-HX: 2m

  • Dpcore: 0.1 MPa = 60% Dptot

Note: ULOF becomes very unlikely is spallation loop pump and PHXs are supplied by the same electrical circuit