1 / 15

Revised Theory of the Slug Calorimeter Method for Accurate Thermal Conductivity and Thermal Diffusivity Measurements

This paper presents a revised theory of the Slug Calorimeter Method for precise thermal conductivity and thermal diffusivity measurements. The method is applicable to fire resistive materials at temperatures up to 1100K. It introduces a more accurate formula for thermal conductivity calculations and demonstrates the feasibility of obtaining the volumetric specific heat ratio using accurately measured relaxation time. Experimental validation confirms the validity of the new formulas.

ccooper
Download Presentation

Revised Theory of the Slug Calorimeter Method for Accurate Thermal Conductivity and Thermal Diffusivity Measurements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Revised Theory of the Slug Calorimeter Method for Accurate Thermal Conductivity and Thermal Diffusivity Measurements Akhan Tleoubaev, Andrzej Brzezinski Presented at the 30th International Thermal Conductivity Conference and the 18th International Thermal Expansion Symposium September, 2009, Pittsburgh, Pennsylvania, USA

  2. Slug Calorimeter

  3. The Slug Calorimeter Method for thermal conductivity measurements of the fire resistive materials (FRM) at temperatures up to 1100K (~827C) • ASTM E2584-07“Standard Practice for Thermal Conductivity of Materials Using a Thermal Capacitance (Slug) Calorimeter” Committee E37 on Thermal Measurements

  4. Approximate formula for thermal conductivity used in the Slug Calorimeter Method until now:  l (T’/t)x(M’Cp’+MCp)/(2AT) was obtained using the 2nd order polynomial: T(z,t)  T’(t) + a(t)z + b(t)z2

  5. More accurate approximate formula for thermal conductivity can be derived using the 3rd order polynomial: T(z,t)  T’(t)+a(t)z+b(t)z2+c(t)z3 Thermalproblem: P.D.E.:  x 2T/z2 = Cp x T/t B.C. at z=0: C’p’l’/2 x T’/t=  x T/z z=0 B.C. at z=l: T(l,t)=Ft

  6. Coefficients a(t), b(t), and c(t) can be found as: a(t)= C’p’l’ x (T’/t)/(2) -from B.C. at z=0 b(t)=Cp x (T’/t)/(2) -from P.D.E at z=0 c(t)=[F- (T’/t)] x Cp/(6l) -from P.D.E. and B.C. at z=l New formula for thermal conductivity:   (l/2)[(T’/t) ( C’p’l’ + Cpl ) + + (Cpl/3)/(F- T’/t)] /T

  7. Volumetric Specific Heat Cpcan be found by recording the slug’s T’ relaxation when the outer T (z=l) is maintained constant. Same thermalproblem: P.D.E.:  x 2T/z2 = Cp x T/t B.C. at z=0: C’p’l’/2 x T’/t=  x T/z z=0 Only B.C. at z=l now is: T(l,t)=0

  8. Regular Regime (A.N.Tikhonov and A.A.Samarskii “Equations of Mathematical Physics” Dover Publ., 1963, 1990)

  9. Regular Regime At large t the sum of the exponents degenerates into a single exponent: T(z,t)  exp{-k12t} [A1cos(1l)+B1sin(1l)]= = exp{-t/} T(z) This late stage is the so-called “regular regime” Where  =1/(k12) is relaxation time T(z) is the time-invariant temperature profile

  10. Analytical solution of the thermal problem isa transcendental equation for eigenvalues (M. Necati Özisik “Boundary Value Problems of Heat Conduction” Dover Publications, 1968):(ml) x tan(ml)/2 = Cpl /(C’p’l’)where m are roots of the equation.Relaxation time  can be calculated from the slope of the logarithm of T vs. time. Reciprocal of the slope equals =1/(k12)Experimental check of the solution was done using 1/8”-thick copper plateand two ½”-thick EPS samples.

  11. System of two equations with two dimensionless unknowns: • 1) Dimensionless thermal similarity parameter: = 1l = l/(k)1/2= Fo-1/2 • 2) Dimensionless ratio of the specific heats (and thicknesses): Cpl /(C’p’l’)

  12. Solution of the system is in another one transcendental equation: • f() = (Ft-T’)/(dT’/dt)/ - - 2[(F/6/(dT’/dt)+1//tan()+1/3] = 0 which can be solved by iterations using e.g. Newton’s method: [j+1] = [j] – f ([j])/ f’ ([j]) f’ ()=-F/3/(dT’/dt)-1/tan()+/sin2()-(2/3)

  13. Percent of errors of the slug’s T’ calculated using old and new formulas vs. time in seconds.

  14. Thermal conductivity vs. time calculated by old, and by new formulas using known Cp, and by new formula without using the known Cp, but using only accurately measured relaxation time 

  15. Conclusions • Theory of the Slug Calorimeter Method was revised. More accurate formula has been derived for thermal conductivity calculations. • Volumetric specific heat ratio can be obtained using another one new formula and accurate registration of the system’s relaxation time. • Experimental check proved validity of the new formulas. Thus, in general, all four thermal properties , Cp,k, and  can be measured using the new formulas and two-step procedure – first, maintaining the outer temperature constant, and then changing it at a constant rate.

More Related