The . 50F5 Modular Ionizers. Ionizer modules can be rack or flange mounted to fresh air inlet duct or recirculation plenum or duct Power consumption only 50 watts per module Oxygen present in air flow over tubes becomes bipolar - ionized and reactive

Download Presentation

The

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Slide1 l.jpg

The


50f5 modular ionizers l.jpg

50F5 Modular Ionizers

  • Ionizer modules can be rack or flange mounted to fresh air inlet duct or recirculation plenum or duct

  • Power consumption only 50 watts per module

  • Oxygen present in air flow over tubes becomes bipolar - ionized and reactive

  • Ionized air flows via HVAC air distribution ducts to building or enclosure

  • No ozone produced.


Slide3 l.jpg

And


Heritage lift station san jacinto river authority the woodlands texas 77380 l.jpg

Heritage Lift Station San Jacinto River Authority The Woodlands, Texas 77380

  • A very smelly lift station is positioned within a few feet of the property line of a $1M home

  • End of pipe systems including chemical drum scrubbers and chemical spray systems did not solve the problem

  • Trans-Tech custom designed and installed an air ionizer system with positive pressure air feed on April 2, 2001

  • Within minutes the wet well exhaust was clean and odor free.

Trans-Tech Energy and Environmental, Inc.

9212 Highland Road, Pittsburgh, PA 15237

Phone: 412-366-9177 www.trans-tech.org

PATENT PENDING


Slide5 l.jpg

Waste Processing Room Applications

Exhaust

Inlet Air

Ionizers


Three rivers mi preliminary treatment building air ionization l.jpg

Three Rivers, MI, Preliminary Treatment Building Air Ionization

Retrofit Reznor air handling unit

inlet hood to accept modular air

ionizer units

Four 50F5 modules are

rack mounted.

FS200 ion level

controller controls

ion level in room.

Bipolar oxygen ionization

eliminates

odor and reduces

corrosion.

Ionized air flow

enters room through air inlet ducts


Denver mwrd sludge processing building basement pre design demonstration scale pilot l.jpg

Denver MWRD Sludge Processing Building Basement Pre-design Demonstration Scale Pilot

46 PPM H2S

Five (5) model 50F5 ionizer modules installed in duct

Ionized air

Aisles prior to ionization 5 PPM H2S

Aisles after ionization 0 PPM H2S


Denver mwrd sludge processing building basement pre design pilot l.jpg

Denver MWRD Sludge Processing Building Basement Pre-design Pilot

Pilot Ionization Plenum

Ionized air flow

Dump Zone 46 PPM H2S prior to Ionization

Dump Zone 0-2 PPM H2S after ionization


Mwrd denver from pilot to system design and installation l.jpg

MWRD Denver from Pilot to System Design and Installation

  • 50F5 modular ionizers will be flange mounted to plenums

  • Shown during construction is one (1) of two (2) twenty-four (24) module MWRD plenums

  • Total treated volume includes the SPB Basement at 26,800 CFM (45,543 M3/Hr.) and Cake Storage Building at 16,700 CFM (28,373 M3/Hr.)

  • MWRD ionization system coming on line September 2003.


Cost comparisons dewatering buildings l.jpg

Cost Comparisons Dewatering Buildings


Conclusions l.jpg

CONCLUSIONS

  • Bipolar air ionization provides a simple and cost effective odor control solution

  • Added value includes corrosion control, health and safety advantages

  • Recommendation: Do not allow simplicity of concept to be misinterpreted as lack of need for thoughtful system design and engineering.

  • Total costs - capital plus O&M are less than “end of pipe” odor control system alternatives.