An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam Q&As HCIA-Data Center Facility V2.0 https://www.passcert.com/H12-411_V2.0-ENU.html

  2. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 1. CORRECT TEXT The computer room air conditioner is suitable for scenarios _. Answer: modular data centers, container data centers, medium and large data centers

  3. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 2. The following Does the model of air conditioner have an oil separator? A. NetCol5000-A25kW B. NetCol5000-A35kW C. NetCol8000-A50kW D. NetCol5000-C30kW Answer: A,B

  4. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 3. The following is for high frequency ups. The correct description of the rectifier components is. A. Complete AC to DC conversion B. Complete DC to AC conversion C. Realize power factor correction and pressure reduction function D. Realize power factor correction and boost function Answer: A,D

  5. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 4. The following air conditioners do not need to install cooling towers. A. Air-cooled direct expansion air conditioner B. Water-cooled air conditioner C. Air-cooled chilled water air conditioner D. Water-cooled chilled water air conditioner Answer: A,C

  6. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 5. The following () options belong to water-cooled chilled water air conditioners. (Multiple choice) A. No need to install a cooling tower B. Only for small data centers C. need to install a cooling tower D. Suitable for medium and large data centers Answer: C,D

  7. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 6. Which of the following statements about the battery is wrong: A. The battery room should prevent the temperature from being too high to prevent thermal runaway. B. The reason for the swelling of the battery is that the pressure becomes higher due to excessive gas evolution. C. When the battery reaches the end of its service life, it does not require special treatment and can be sold directly to scrap for recycling. D. When the battery leaks, do not touch it directly with your hands. Answer: C

  8. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 7. The function of the following () parts is to help with oil return. A. liquid lens B. oil sight glass C. Oil trap D. reverse bend Answer: C

  9. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 8. In the data center power supply and distribution system, the low- voltage circuit breaker with three-stage protection feature is used for. A. Prevent branch circuit short circuit caused by branch circuit overload B. Prevent the main circuit from being overloaded due to the short circuit of the branch circuit C. Prevent the main circuit from breaking due to branch circuit breaking D. Prevent the main circuit from breaking due to a short circuit in the branch circuit Answer: B,D

  10. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 9.The following air conditioning, which is comfort air conditioning? A. room dedicated air conditioning B. Clean air conditioning C. Commercial air conditioners D. Medical air conditioning Answer: C

  11. Free HCIA-DCF H12-411_V2.0-ENU Practice Exam From Passcert for Your Best Preparation 10.In the data center power supply and distribution system, if a power outage occurs, it is generally caused by Complete the standby switch between mains and mains or mains and diesel generators. A. Automatic transfer switch system B. Diesel generator system C. Low-voltage power distribution system D. Rack power distribution system Answer: A