1 / 13

Adaptive Lyot Mask

Adaptive Lyot Mask. In order to optimize the occulting process of a Lyot coronograph , a new kind of occulting disk as been developped at the National Observatory of Rio de Janeiro, to provides a high dynamic imaging .

carrie
Download Presentation

Adaptive Lyot Mask

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Adaptive Lyot Mask In order to optimize the occulting process of a Lyot coronograph , a new kind of occulting disk as been developped at the National Observatory of Rio de Janeiro, to provides a high dynamic imaging . A mercury (Hg) drop glueded on to an optical window by molecular cohesion and compressed by a pellicular film is used as the occulting disk. The minimum of the superficial tension potential function provides an optical precision (lambda/100) of the toric free surface of the mercury. This process provides a size control for the adaptation to the seeing conditions and to the apparent diameter of a resolved object, and in the case of adaptive optics, to the Airy diameter fraction needed. The occultation is a three dimensional process near the focal plane on the toric free surface that provides an apodization of the occultation. The Hg-Mask coronograph has been projected for astrometric observations of the inner Neptunian satellite Proteus and works since 2000 at the 1.6m telescope of the Pico dos Dias Observatory (Minas Gerais – Brazil). “A coronograph with a variable diameter occulting disk” Bourget et al. (2001), PASP 113. “Coronographie de Lyot a masque de mercure” Bourget et al. (2003). Deuxiemes Journées d´Imagerie à Très Haute Dynamique, Nice, France.

  2. Second prototype at the 1.6m Telescope of the OPD – Brasil. Astrometric observations program of Jovian satellites since 2000. • -Hg Mask size control. • -Internal Flat. • Intensified way for the Mask centering process and pupil image visualisation.

  3. 5’*5’Field for the astrometric calibration Proteus - Neptune – Proteus 10‾5 Dynamic 2000-2002: 66 astrometric positions

  4. V (Neptune) = 7.8 V (Proteus) = 20.3 Texp = 10 – 20 s Separation 5´´

  5. Uranus – Puck 1.5 10‾6 Dynamic V (Uranus) = 5.7 V (Puck) = 20.4 Separation 5´´ Oberon Miranda Umbriel Ariel Titan Miranda Puck Umbriel

  6. Construction of an Hg-Mask coronograph for the Pic Du Midi Observatory (France), delivery in February 2004. First tests October 2003, at the T1m telescope: Pleione (Hα) HR1180-280 HD 23 862 Bourget, Colas, Assus Observations realised for Farrokh vakili (LUAN – Nice) Rotational gradient visu

  7. Hg-Mask Mercury drops compression range: Duplication of the diameter Precompressed Compression limit Nitrocellulose pellicle Toric free surface of mercury Optical window Example of Hg-Drops 50 μm to 250 μm Size : limit max 1.5mm limit min 10μm

  8. Construction of a tip-tilt correction and automatic centring system of the coronograph (first light in 2002). The originality of this system in development is to use the dynamic diffraction signal behind the occulting disk as a tilt parameter. A “loop” on the Hg-Mask size provides an optimization of the dynamic correction of the tip-tilt. Optical quality distorssion : 20*20 mm field:

  9. First Light 2002 First cavity Hg-Mask CCD Tip-Tilt fiber sensor Carbon fiber structure

  10. Tip-Tilt sensor- First test Small field coronograph Fiber entrance__ APD Quadrant fiber guide 50μm fiber quadrant Four APD as quadrant

  11. Inductive controlTip-Tilt Mirror

More Related