Beispiel: Wahl von geeigneten Thermostatventilen
Download
1 / 27

1150 W - PowerPoint PPT Presentation


  • 81 Views
  • Uploaded on

Beispiel: Wahl von geeigneten Thermostatventilen. Bestimmung der Volumenströme Festlegung der Durchmesser Ermittlung der Druckverluste. 75°C. ThV2. ThV1. 700 W. 1150 W. WEZ. 55°C. Beispiel: Wahl von geeigneten Thermostatventilen. Bestimmung der Volumenströme

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' 1150 W' - carol-swanson


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

Beispiel: Wahl von geeigneten Thermostatventilen

  • Bestimmung der Volumenströme

  • Festlegung der Durchmesser

  • Ermittlung der Druckverluste

75°C

ThV2

ThV1

700 W

1150 W

WEZ

55°C


Beispiel: Wahl von geeigneten Thermostatventilen

  • Bestimmung der Volumenströme

  • Festlegung der Durchmesser

  • Ermittlung der Druckverluste

0,051 m³/h

0,082 m³/h

75°C

0,031 m³/h

ThV2

ThV1

700 W

1150 W

WEZ

55°C


Beispiel: Wahl von geeigneten Thermostatventilen

  • Bestimmung der Volumenströme

  • Festlegung der Durchmesser

  • Ermittlung der Druckverluste

alle Rohre DIN EN 10255 - DN10

0,051 m³/h

0,11 m/s

0,082 m³/h

0,18 m/s

75°C

0,031 m³/h

0,07 m/s

ThV2

ThV1

700 W

1150 W

WEZ

55°C


75°C

??? Pa

DIN EN 10255; DN 10

0,082 m³/h

0,18 m/s

l = 2,4 m

1 WEZ; 1 Ventil; 10 Bögen

700 W

1150 W

WEZ

55°C


75°C

300 Pa

  • DIN EN 10255; DN 10

  • 0,082 m³/h

  • 0,18 m/s

  • = 11

  • l = 2,4 m

700 W

1150 W

WEZ

55°C


0,051 m³/h

0,11 m/s

200 Pa

400 Pa

800 Pa

1600 Pa

300 Pa

75°C

100 Pa

  • DIN EN 10255; DN 10

  • 0,082 m³/h

  • 0,18 m/s

  • = 11

  • l = 2,4 m

ThV1

ThV2

700 W

1150 W

100 Pa

0,031 m³/h

0,07 m/s

WEZ

55°C

300 Pa

800 Pa

1600 Pa


200 Pa

400 Pa

800 Pa

1600 Pa

300 Pa

75°C

100 Pa

ThV1

ThV2

700 W

1150 W

100 Pa

WEZ

55°C

300 Pa

800 Pa

1600 Pa


200 Pa

400 Pa

800 Pa

1600 Pa

300 Pa

75°C

100 Pa

ThV1

ThV2

700 W

1150 W

100 Pa

WEZ

55°C

300 Pa

800 Pa

1600 Pa


75°C

ThV2

ThV1

700 W

1150 W

WEZ

55°C

3000 Pa

ohne THV

6000 Pa





0,1m3/h

0,05m3/h

Typ D

Typ C


0,05m3/h

0,05m3/h

Typ D

Typ B





75°C

ThV2

ThV1

700 W

1150 W

WEZ

55°C

12000 Pa

mit THV

12000 Pa






Auslegung 3-WV: b = 11200/600 = 18,7

400 Pa

800 Pa

1600 Pa

300 Pa

75°C

100 Pa

ThV1

ThV2

700 W

1150 W

100 Pa

WEZ

55°C

300 Pa

800 Pa

1600 Pa

600 Pa

11200 Pa


keine Ventilautorität erforderlich

Hoher kvs (niedriges Delta-p) günstig

Wahl des Ventils rein nach DN


  • Auswahl Pumpe:

  • Vp = 0,082m³/h

  • Delta-P = 12000 Pa  h_P = 12000 Pa/(rho * g) = 1,24 m

200 Pa

400 Pa

800 Pa

1600 Pa

300 Pa

100 Pa

75°C

9000 Pa

6000 Pa

700 W

1150 W

100 Pa

WEZ

55°C

300 Pa

800 Pa

1600 Pa


ad