  • Uploaded on

MICE. TECHNICAL UPDATE & ISIS/RAL PLANS. Acknowledge. Belgium Italy Japan The Netherlands Russian Federation Switzerland UK USA. RAL & ISIS. RAL. Harwell. ISIS. Location. Plant…. Control room… Electronics…. ISIS Ring. Experimental Hall. Hall: L = 47 m W = 12 m H = 8 m

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' MICE' - carnig


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

MICE

TECHNICAL UPDATE &ISIS/RAL PLANS


Acknowledge
Acknowledge

Belgium

Italy

Japan

The Netherlands

Russian Federation

Switzerland

UK

USA


Ral isis
RAL & ISIS

RAL

Harwell

ISIS


Location
Location

Plant….

Control room…

Electronics….



Experimental hall
Experimental Hall

Hall:

L = 47 m W = 12 m H = 8 m

S = 564 m2 V = 4512 m3

Two overhead cranes (8 tonnes each)


Mice hall
Mice Hall

Existing Area & Beam Line

-- is still there - as seen in Summer

-- Beam Line used to end of year



Technical update issues
Technical Update & Issues

  • Beam Line

  • RF System

  • Absorbers

  • Magnets & Cryogenics

  • Detectors

  • Infrastructure & Layout

  • RAL & ISIS Perspectives

  • Programme

  • Expected Progress



Beam line

Pm < 400 MeV/c

Rejection of protons and pions <10%

few muons per ms

Two solutions:

solenoid

cryogenics availability

release by PSI

quadrupoles

Beam Line



Performance
Performance

Rate depends on muon momentum:

e.g. at 200 MeV/c

3000 / ms for solenoid

~300 /ms in quadrupole

(assumed a Ti wire target: 1cm long and 4mm Ø)

Purity should be better than 90% against scattered protons


Rf system

Solenoid Magnet

Cooling Channel

Envelope

RF Cavity

Cavities

Raft

Absorber

Tuning

Bellows

RF System

1 MW per cavity

8MW total

Low Duty Factor

1-2 ms

1-10 Hz

average power

~1kW/Hz


Rf drive
RF Drive

7651

RS2058

EX SPS

TH116

DRIVE TO 4 CAVITIES VIA PHASE SHIFTERS AND 70db COUPLERS POWER SPLITTERS AND CIRCULATORS

TH781

EX RAL

4kW

10mW

40kW

4MW

400kW

12kV

5kV

40 kV

20 kV

LEVEL CONTROL

- a possible scheme

~

SOURCE

OTHER DRIVE CHAIN

R.A. Church RAL


Absorber i

Liquid Hydrogen – Major safety issue

ISIS Liquid Hydrogen Moderator

Absorber I





Magnets cryogenics
Magnets & Cryogenics

Principle Issues – Fringe Fields

– Cryogenic Requirements

Blue contours:

10 mT

Orange:

0.5 mT


Detectors
Detectors

Issues:

SiFi - Large cyro cooling needed for VLPCs

TPG – HV & flamable gas (next to Lig.H cell)


Infrastructure
Infrastructure

Plant: Electrical Power

Cooling Power

Cryogenic System

Hydrogen Delivery & Handling

Installation

phased build of the experiment


Isis perspective
ISIS Perspective

  • Critical Issues: Beam Line

  • Long Shutdown

  • Break into ISIS Synchrotron from MICE Hall

  • Have Shielding available+

  • Have Stands available

  • Competes with other ISIS projects

    • 300 mA upgrade*

    • Second Target Station*

    • RFQ Installation

    • delivery of contracted neutron amp.hours

    • * work in synch. vault +2nd target station – friend or foe?



Expected progress
Expected Progress

Proposal submitted expect the review to take place Mid Feb till May (?) - international review panel

MICE is part of the UK’s Science road map - but funds are not yet allocated

Internal Review  green light following international rp

Management & Oversight Structure(s) need to be in place


ad