Load sensors conditioners radiation tests
This presentation is the property of its rightful owner.
Sponsored Links
1 / 11

Load sensors conditioners – radiation tests PowerPoint PPT Presentation


  • 80 Views
  • Uploaded on
  • Presentation posted in: General

Load sensors conditioners – radiation tests. Mateusz Sosin BE/ABP/SU. RADWG, 15.11.2011. Summary. Load sensors under Low-Beta quadrupoles – introduction Load sensors – signal conditioner Conditioner crate – components & radiation tests Questions.

Download Presentation

Load sensors conditioners – radiation tests

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Load sensors conditioners radiation tests

Load sensors conditioners – radiation tests

Mateusz Sosin

BE/ABP/SU

RADWG, 15.11.2011


Summary

Summary

Load sensors under Low-Beta quadrupoles – introduction

Load sensors – signal conditioner

Conditioner crate – components & radiation tests

Questions

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors under low beta quadrupoles

Load sensors under Low-Beta quadrupoles

  • Monitoring and adjustment system

    • Monitoring alignment systems: Wire Positioning Systems – (WPS) and Hydrostatic Levelling Systems (HLS) are installed on top of the cryostat (precision of measurements of a few microns)

    • Motorization of the Jacks according to 5 DOF

    • 10 Vertical and 6 Radial Jacks per triplet

  • Problem of loosing articulation point detected at february 2011 !!!

    • Unexpected 0.8mm Q3R5 magnet jump during repositioning dangerous for installation

    • Reported by D.Missiaen at LMC – 02.03.2011

    • Load sensor solution proposed

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors under low beta quadrupoles1

Load sensors under Low-Beta quadrupoles

  • Constraints

    • Very low possible space for sensor installation (ø70, h16 mm)

    • High load (up to 15T)

    • Radioactive area

  • Sensor

    • Strain gauge – force washer type sensor

    • Solution tested

    • After market study - choosed German HBM MPZ1108010

    • Rad-hard qualified

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors under low beta quadrupoles2

Load sensors under Low-Beta quadrupoles

  • Configuration per one IP side:

    • Installation for IP1,2,5,8 L&R

    • Compatible with other SU instalations

S.A.S.tested by A.Marin

EDMS 1062166,

FipADUC cards tested by

R.Denz

?

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors conditioners radiation tests

Load sensors – signal conditioner

  • BE-ABP-SU conditioners (Analog Devices AD7730 + ’51 based)

    • Cheap (0.1kCHF per channel)

    • Suited for application

    • Basic DSP abilities included

    • AC/DC modes & cable compensation

  • Suitable market accesible conditioners

    • Expensive (0.6..1kCHF per channel)

    • Additional cabling needed

    • We have no influence for used components

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors conditioners radiation tests

Load sensors – signal conditioner

  • BE-ABP-SU prototype and HBM-AE301 conditioners checked at specialtest bench

    • Similar noise with 270m cables

    • High output signal stability for both conditioners

    • Both solutions suitable for Low-Beta weighting system application

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors conditioners radiation tests

Load sensors – signal conditioner

  • SOLUTION: Basing on Survey Acquisition System electronics – create load sensors conditioning crate

    • Use same part of electronics like in S.A.S. (FipADUC card)

    • Add one PCB (12 channel input stage) in place of old S.A.S. input amplifiers board

FIP ADUC CARD

FIP ADUC CARD

CONN.TAPE

CONN.TAPE

S.A.S. INPUT AMPLIFIERS BOARD

LOAD SENSORS

12 CHANNEL INPUT

STAGE PCB

  • Advantages

    • No additional cabling between conditioner and S.A.S.

    • Small space in SU racks needed

    • No big updates at FESA/PVSS level needed

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors conditioners radiation tests

Conditioner crate – components & radiation tests

  • Semiconductors proposed for 12-channel input stage of conditioner crate:

    • 12 x AD7730 – Analog Devices, CMOS, 24-Bit Sigma-Delta, Bridge Transducer ADC for Load Cell Applications (not tested)

    • 12xMIC4427 – Micrel, MOSFET driver (not tested)

    • 1xCPLD XC95144 – Xilinx CPLD, 144 macrocells, triple mode redundancy (5V logic compatible preffered), Actel if no agreement

    • 1xADUC8xx – Analog Devices, ’51 based MCU with ADC & 12bit DAC (used in FipAduc, tested 100Gy)

    • 12xLED HLMP-1700 or HLMP-1790(tested 100Gy)

    • 4x rectifying diodes 50WQ03FN(tested100Gy)

    • 1x LM7805 – Linear voltage stabilizer (tested 100Gy)

    • 2x Rail-To-Rail operational amplifier (Vcc=5V ?)

FIP ADUC CARD

CONN.TAPE

LOAD SENSORS

12 CHANNEL INPUT

STAGE PCB

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors conditioners radiation tests

Conditioner crate – components & radiation tests

  • Equipment locations:

    • IP1: US15

    • IP2: UA23, UA27

    • IP8: UA83, UA87

    • IP5: UJ56 -> after LS1 UL55

  • Equipment quantity:

    • Each IP -> 2 crates (10 channels for sensors + 2 spares)

    • 8 crates in total

Load sensors conditioners – radiation tests RADWG, 15.11.2011


Load sensors conditioners radiation tests

Questions

?

  • According to future locations of new eqipment and radiation levels– how big is risk of radiation fails in installation places?

  • Because of installation works urgency– is it possible to install electronics and perform the tests later? In that case: Can we treat temporarly our components locations as ‘radiation safety’ areas?

  • According to problems with Xilinx XC95.. CPLD family we can change it for Actel ProAsic3, but is it really necessary in this case?

  • ADC tests: AD7730 & future SAS generation...

Load sensors conditioners – radiation tests RADWG, 15.11.2011