Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA)

Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA). C h e m. Cristina CIAMA, EHS M anager, Mihail GEORGESCU, Safety Inspector S.C EUROPHARM S.A Brașov.

cai
Download Presentation

Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) Chem. Cristina CIAMA, EHS Manager, Mihail GEORGESCU, Safety Inspector S.C EUROPHARM S.A Brașov

  2. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) • Issue • Many of the Active Pharmaceutical Ingredients (API) used in the pharmaceutical production industry have the potential of causing occupational illness (e.g. skin rash, dermatitis, asthma, etc). • Using the right tools and process to assess the chemical risk at workplace • Problem • Employees working in pharmaceutical industry are exposed to pharmaceutical substances causing risk to their health. The ways of exposure to the chemical substance are various as skin, respiratory, ingestion, eye. • The company set up Key Performance Indicators (KPI) on occupational health injuries and illnesses to monitor the performance on employees’ health and safety • 3 potential allergies at skin level have been reported

  3. Improvement of Personal ProtectiveEquipment (PPE) as a result of chemical risk assessment (CRA) • Solution • Investigation • Following the reporting, an investigation committee has been set-up in order to find out the root cause of incidents • Tools used during investigation: • ROOT CAUSE ANALYSIS (RCA) • FISH BONE ANALYSIS • GEMBA tour • Root Cause • Chemical Risk Assessment undertook is addressing few aspects and does not take into consideration the risk of employees’ exposure to chemical substances

  4. Improvement of Personal ProtectiveEquipment (PPE) as a result of chemical risk assessment (CRA) • Project Steps • Step 1 Establish the target • Improvement of Chemical Risk Assessment • Step 2 Set-up the project team • with members from all relevant departments • Step 3 Identify the best solutions • Introduce information about ways of exposure: inhalation/ingestion and skin contact • Introduce a risk quantification • Introduce types of chemical contact • Introduce R phrases • Link between risk assessment and occupational monitoring • Involvement of operators in chemical risk assessment process • Step 4 Implement the new WOW • Training of the employees on CRA methodology • Training on chemical effects • Deployment of new CRA

  5. Improvement of Personal ProtectiveEquipment (PPE) as a result of chemical risk assessment (CRA) CHEMICAL RISK ASSESSMENT METHODOLOGY • Occupational Health Category • Occupational Hazard Categories (OHCs) is in-houseGSK ranking tool for practical assessment of the health hazards of substances. • An Occupational Hazard Category (OHC) is defined as a grouping which classifies compounds based on health hazards. • The specific hazards of materials within an OHC may not be comparable, but to avoid ill-health following exposure, all materials in an OHC require control to the same degree. In the GSK OHC system the least hazardous materials are classified as OHC 1; the most hazardous as OHC 5. 5. OHC 5 - < 1mcg/m3 ( 8HrTWA)

  6. Improvement of Personal ProtectiveEquipment (PPE) as a result of chemical risk assessment (CRA) CHEMICAL RISK ASSESSMENT METHODOLOGY Quantification method: take into consideration the way of exposure: inhalation/ingestion and skin contact Assessment of exposure through inhalation/ingestion Quantification: Likelihood x Consequence

  7. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) Calculation of Likelihood: Dustiness x Duration x Quantity x Frequency

  8. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) Example of quantification for inhalation risks • Task: Dispensing/Weighting of Amoxicillin • Transfer of bulk powder by vacuum • Frequency: once per day • Duration: 15-30 min • No of operators: 1 Probability inhalation: 4 x 2 x 2 x 1 = 16

  9. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) Example of quantification for inhalation risks: Likelihood inhalation: 4 x 2 x 2 x 1 = 16 Score under 20 means RARE Consequence: is OHC 3 that means Score 3 Result: risks of inhalation for this task is in green area, that should be kept under control

  10. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) Assessment of exposure through skin contact: CHEMICAL RISK ASSESSMENT METHODOLOGY Assessment of exposure through skin contact Quantification: Likelihood x Consequence

  11. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) Example of quantification for skin contact risks: • Task: Dispensing/Weighting of Amoxicillin; Transfer of bulk powder by vacuum pump. Frequency: once per day. Duration: 15-30 min. No of operators: 1 Severity is OHC 3 that means Score 3 Probability skin contact: 2 x 2 x 1 = 4 Result: risks of skin contact for this task is in green area, that should be kept under control

  12. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) Notice: Scoring CHEMICAL RISK ASSESSMENT METHODOLOGY • If the CRA identifies nonconformities that affect the operator’s health, the scoring could be increased even the calculation is showing a lower score! CRA Template 1Prioritate: scazuta, medie, inalta

  13. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) CRA Template

  14. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) CRA Template If in section C Reproductive Risks will be identified through R Phrases, we should proceed to specific Risk Assessment and eliminate/reduce exposure using Hierarchy Controls Method If in section C Carcinogen Risks will be identified through R Phrases, we should proceed to eliminate/reduce exposure using Hierarchy Controls Method

  15. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) CRA Template

  16. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) CRA Template • RESULTS • operators involvement in CRA process • cross reference with the OH monitoring results

  17. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) • PPE Improvement • ½ length latex gloves replaced by ¾ length nitril gloves • Standardize the RPE in production area • Remove the RPE for the areas where OH monitoring shows results less than OEL • For the glove selection process, introductionofnew criteria as permeation parameters • Redesign of clothing equipment in order to minimize the skin exposed areas

  18. Improvement of Personal Protective Equipment (PPE) as a result of chemical risk assessment (CRA) • BENEFITS • a structured approach of CRA • Chemical 5x5 risk quantification system allows quick ranking of the risk and helps on action prioritization • increase the ownership and understanding at shop floor level of chemical risks • COMMENTS • Health and Safety of the employees is always an important part of GSK, and therefore it is important to find ways to minimise EHS risks and impacts to create and develop a healthy work-place. • This CRA methodology has been recognized as Good Practice in the GSK network • “In addition we aim to continue improving process safety and to move toward an environment where containment rather than respirator is the primary control of chemical exposure” (quote David Pulman, President Global Manufacturing and Supply GSK)