EMG Lab Data Collection

EMG Lab Data Collection. Toru Tanaka, Miguel Narvaez, Adam Bruenger, and members of the Spring Semester KIN 831 Course. Worn about subject’s waist Receives incoming voltage signals (e.g., EMG, force transducers, metronome, electrogoniometer) 2 sets of 8 pairs of differential leads

Download Presentation

EMG Lab Data Collection

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMG Lab Data Collection Toru Tanaka, Miguel Narvaez, Adam Bruenger, and members of the Spring Semester KIN 831 Course

  2. Worn about subject’s waist • Receives incoming voltage signals (e.g., EMG, force transducers, metronome, electrogoniometer) • 2 sets of 8 pairs of differential leads • 1 common (ground) lead per set • 1 set of 8 DC differential channels • Amplifies incoming analog signals • 2 sets of pairs of 8 differential channels (gain set at 1, 2, 5, or 10 K) • 8 DC differential channels (gain set at 1, 1.333, 2, or 4 K) • Samples • Each of 16 differential channels at 8 KHz • Each of 8 DC differential channels at 1.6 KHz • Converts analog signals into digital signals • Transmits digital signal to receiver via fiber optic cable MYOPAC Belt Unit

  3. MYOPAC Receiver Unit • Receives digital optical signals from MYOPAC belt unit • Converts digital signals back to analog signals • Makes signals available to suitable analog signal recording system (e.g., analog to digital converter, oscilloscope, computer) • Full scale output of receiver unit = 5 volts

  4. Output of signal to computer Analog to digital converters of input signals

  5. Calibration of Input Signals • EMG – signals amplified by selected gain (assume linear amplification of all signals) • Metronome – only temporal signal needed; not concerned for magnitude of signal • Electrogoniometer – check voltage output over range of angles expected; assume linearity of output signal • Torque – check torque value at expected maximum and minimum; assume linearity of output signal (see next slide)

  6. Calibration of Torque Signal • Measure length of calibration bar from pivot to center of cross member (e.g., 0.765 m) • Level calibration bar • Load calibration bar with known mass (e.g., 40 kg  392.4 N) • Torque = force x perpendicular distance (e.g., 392.4 N x 0.765 m = 300.186 Nm) • Use volt meter to read output voltage for known torque (e.g., 5.31 volts) • Reorient calibration bar in vertical position • Output torque should = 0 volts (actual voltage = 0.01volts) • Calculate volts per unit of torque assuming linearity of output signal (e.g., 56.64 Nm per volt)

  7. Identify Central Contractile Region of Muscles to be Tested • Use anatomical reference source • Apply resistance to prime movement of muscle while subject contracts muscle • Palpate muscle (e.g., rectus femoris) • Attempt to distinguish from other muscles in vicinity (e.g., vastus lateralis and vastus medialis) to reduce chance of cross talk

  8. Prepare Skin for Surface Electrodes • Clean skin 2. Shave skin 3. Clean skin 4. Abrade skin 5. Clean skin

  9. Position Surface Electrodes • Use pair of electrodes for common mode rejection • Determine position near belly of muscle to be recorded • Orient pair of electrodes with respect to line of pull of muscle and/or orientation of muscle fibers • For consistency, measure distance between recording surfaces

  10. Prepare Additional Muscles for Surface Electrodes Medial head of gastrocnemius

  11. Note the use of loop in electrode wires prior to taping leads and electrodes. This may protect electrode from dislodging if leads are pulled.

  12. Prepare Additional Muscles for Surface Electrodes Long head of biceps femoris

  13. Familiarize Subject with Test Environment Click here Restrict Extraneous Movements

  14. Experiment 1 • Variation of Force of Isometric Knee Extension • Isokinetic dynamometer set at 0 degrees/second • Knee angle set at 45 degrees • 3 different isometric contractions: mild, intermediate, and forceful (subject attempts to maintain constant force throughout each contraction) • Record rectus femoris EMG, knee extension torque, and joint angle • All signal sampled at 2 KHz • 3 data files

  15. Based on your knowledge of muscle mechanics and electrophysiology what would you expect?

  16. Experiment 2 • Electromechanical Delay (EMD) in Isometric Knee Flexion • Isokinetic dynamometer set at 0 degrees/second • Knee angle set at 45 degrees • Record long head of biceps femoris EMG • Signal sampled at 2 KHz • Subject begins with biceps femoris relaxed, turns muscle on quickly (quick contraction), holds contraction for approximately 3 seconds, then relaxes muscle quickly • Begin recording prior to contraction and end recording after turnoff of contraction • 1 data file

  17. Based on your knowledge of muscle mechanics and electrophysiology what would you expect?

  18. Experiment 3 • Concentric Isokinetic Knee Extension Under Different Loads and Angular Velocities • 3 angular velocities: 30, 90, and 120 degrees/second • 3 different isokinetic contractions: mild, intermediate, and forceful (subject attempts to maintain constant torque throughout each contraction) • Record rectus femoris EMG, knee extension torque, and joint angle • All signals sampled at 2 KHz • 9 data files

  19. Video Clip from Experiment 3 Mild 30 deg/sec Mild 90 deg/sec Mild 120 deg/sec Intermediate 30 deg/sec Intermediate 90 deg/sec Intermediate 120 deg/sec Forceful 30 deg/sec Forceful 90 deg/sec Forceful 120 deg/sec

  20. Based on your knowledge of muscle mechanics and electrophysiology what would you expect?

  21. Eccentric Isokinetic Knee Extension Under Different Loads and Angular Velocities • 3 angular velocities: 30, 90, and 120 degrees/second • 3 different isokinetic contractions: mild, intermediate, and forceful (subject attempts to maintain constant torque throughout each contraction) • Record rectus femoris EMG and joint angle • All signal sampled at 2 KHz • 9 data files • *Note that recorded torque is the difference between applied torque by experimenter and resistive torque applied by subject (unknown value) Experiment 4

  22. Video Clip from Experiment 4 30 degrees/sec mild, intermediate, forceful 90 degrees/sec mild, intermediate, forceful 120 degrees/sec mild, intermediate, forceful

  23. Based on your knowledge of muscle mechanics and electrophysiology what would you expect?

  24. Experiment 5 Concentric Versus Eccentric Contraction Under Similar and Different Loads and Angular Velocities *Note that data for this experiment was collected in Experiment 3 and Experiment 4

  25. Based on your knowledge of muscle mechanics and electrophysiology what would you expect?

  26. Skilled Movement Pattern Under Similar and Different Loads and Velocities • Subject performs “skilled” movement pattern consisting of standing from a seated position, holding position, going up onto the toes, holding position, coming down from toes, holding position, sitting back down on the chair, and holding position • Skilled movement pattern is performed under 3 load conditions (body only, body and bar (20 kg), and body and 60 kg • Subject performs skilled movement pattern under 3 frequencies (slow, intermediate, and fast) established by beat of metronome • EMG from rectus femoris, long head of biceps femoris, and medial head of gastrocnemius and metronome recorded at 2 KHz • 9 data files Experiment 6 A variation of Experiment 6 involves recording several repetitions of the skilled movement pattern to determine if there are changes with experience and learning

  27. Video Clip from Experiment 6 “Skilled” Movement Pattern 20 Kg Bar Body Weight 60 Kg Load Slow speed Slow speed Slow speed Intermediate speed Intermediate speed Intermediate speed Fast speed Fast speed Fast speed

  28. Based on your knowledge of muscle mechanics and electrophysiology what would you expect?

  29. Experiment 7 • Fatigue Under Maximum Isometric Knee Extension • Subject attempts to hold maximum isometric knee extension until extensors greatly fatigued • EMG signal of rectus femoris recorded at 2 KHz during early, middle, and late phases of fatigue of muscle • Torque recorded to determine consistency and drop-off • Files of early, middle, and late phases of fatigue recorded

  30. Video Clip from Experiment 7 Muscular Fatigue Start to middle of contractile period Near end of contractile period Fatigued

  31. Based on your knowledge of muscle mechanics and electrophysiology what would you expect?